Datasheet

TRIO-PS/3AC/24DC/5
103346_en_00 PHOENIX CONTACT 8
8 Installation
Adjust
22.5-29.5V
DC OK
Output DC
24 V 5 A
+
+
TRIO POWER
Input 2/3 AC
400-500 V
PE
(L3)
L2
L1
ATTENTION: Module can become
damaged
In order to guarantee sufficient convection, we
recommend observing the following minimum
distance to other modules: 5 cm in a vertical
direction and 0 cm in a horizontal direction.
The power supply unit can be snapped onto all
DIN rails in acc. with EN 60715 and must be
mounted vertically (connecting terminal blocks
on top and bottom).
9 Installation position
Output DC
24 V 5 A
+
+
Adjust
22.5-29.5V
DC OK
TRIO POWER
Input 2/3AC
100-240 V
L1
L2
(L3)
PE
40
130
115
50
230
Mounting position: Installation depth 115 mm (+ DIN rail)