Datasheet

https://www.phoenixcontact.com/de/products/2902029
04/05/2017Page3/11
Signal conditioner-MINI MCR-2-U-I4-2902029
Technical data
General
Maximum transmission error 0.1 % (of final value)
Maximum temperature coefficient 0.01 %/K
Temperature coefficient, typical 0.01 %/K
Limit frequency (3 dB) approx. 30 Hz
Step response (10-90%) approx. 10 ms
Protective circuit Transient protection
Electrical isolation Reinforced insulation in accordance with IEC 61010-1
Overvoltage category II
Degree of pollution 2
Rated insulation voltage 300 V (effective)
Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be
minimal deviations.
Color gray
Housing material PBT
Mounting position any
Assembly instructions
The T connector can be used to bridge the supply voltage. It can be
snapped onto a 35 mm DIN rail according to EN 60715.
EMC data
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Designation Conducted interferences
Standards/regulations EN61000-4-6
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Standards/regulations EN 61000-4-2
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
Designation Conducted interferences
Standards/regulations EN61000-4-6
Electrical isolation Reinforced insulation in accordance with IEC 61010-1
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50