The figure shows the MINI
MCR-2-UI-I-OLP-PT version
Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of
unipolar and bipolar analog signals. Input configurable via DIP switch. Screw connection technology,
standard configuration.
Article description
Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation, conversion, and filtering of analog
signals. The output loop-powered isolator allows operation at an active analog input module. The device is supplied via the current loop
of the controller. On the input side, standard analog signals and non-standard analog signals can be connected, ranging from 2 mA or
50 mV up to 40 mA or 30 V. These are converted to 4 mA ... 20 mA signals. You can configure the input signals via DIP switches. The
measuring transducer supports NFC communication. 
Key commercial data
package_quantity
1
GTIN
4046356652100
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the
download area
Dimensions
Width
6.2 mm
Height
110.5 mm
Depth
120.5 mm
Ambient conditions
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Input data
Configurable/programmable
Yes
Voltage input signal
0 mV ... 1000 mV
Voltage input signal
0 mV ... 750 mV
Voltage input signal
0 mV ... 500 mV