Datasheet

https://www.phoenixcontact.com/us/products/2902851
04/20/2016Page2/6
Thermocouple measuring transducer-MINI MCR-TC-UI-NC-2902851
Technical data
Ambient conditions
Degree of protection IP20
Input data
Configurable/programmable Yes
Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Temperature measuring range
-250 °C ... 2500 °C (Range depends on sensor type, range can be set
freely via software or in increments from -150°C to 1350°C via DIP
switches)
Output data
Number of outputs 1
Configurable/programmable Yes
Voltage output signal 0 V ... 10 V
10 V ... 0 V
0 V ... 5 V
1 V ... 5 V
Current output signal 0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Max. output voltage approx. 12.3 V
Max. output current 24.6 mA
Short-circuit current < 31.5 mA
Load/output load voltage output ≥ 10 kΩ
Load/output load current output < 500 Ω (at 20 mA)
Power supply
Supply voltage range
9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-
ST-3,81 GN, Order No. 2869728) can be used to bridge the supply
voltage. It can be snapped onto a 35 mm DIN rail according to EN60715))
Max. current consumption 72 mA
Typical current consumption < 27 mA (at 24 V DC)
Power consumption
≤ 700 mW (at I
OUT
= 20 mA, 9.6 V DC, load 500 Ω)
Connection data
Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section AWG min. 26
Conductor cross section AWG max. 12
Conductor cross section flexible min. 0.2 mm²