Datasheet
1Description
IEC 62061
SILCL
Safety relay for emergency stop, safety door and
light grid monitoring
PSR-MS60
© PHOENIX CONTACT
Data sheet
Intended Use
The PSR-MS60 safety relay can be used to monitor two-
channel signal generators, e.g.,emergency stop buttons,
safety door locking mechanisms, and light grids, as well as
to control actuators.
The safety relay is equipped with two single-channel en-
abling current paths that drop out without delay according to
stop category 0 and EN60204-1.
The enabling current paths are controlled automatically
once the sensor circuit has been closed.
Features
– Safety relay for emergency stop, safety door, and light
grid monitoring
– Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061)
– 1 two-channel sensor circuit
– 2 undelayed single-channel enabling current paths
– Fixed screw connection
–6.8mm housing width
WARNING: Risk of electric shock
Observe the safety instructions in the corresponding section!
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
This data sheet meets the same requirements as the original operating instructions in terms of contents and is
valid for all products listed on the following pages.