Datasheet

1Description
IEC 62061
SILCL
Safety relay for emergency stop, safety door and
light grid monitoring
PSR-MS60
© PHOENIX CONTACT
Data sheet
Intended Use
The PSR-MS60 safety relay can be used to monitor two-
channel signal generators, e.g.,emergency stop buttons,
safety door locking mechanisms, and light grids, as well as
to control actuators.
The safety relay is equipped with two single-channel en-
abling current paths that drop out without delay according to
stop category 0 and EN60204-1.
The enabling current paths are controlled automatically
once the sensor circuit has been closed.
Features
Safety relay for emergency stop, safety door, and light
grid monitoring
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061)
1 two-channel sensor circuit
2 undelayed single-channel enabling current paths
Fixed screw connection
–6.8mm housing width
WARNING: Risk of electric shock
Observe the safety instructions in the corresponding section!
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
This data sheet meets the same requirements as the original operating instructions in terms of contents and is
valid for all products listed on the following pages.
106171_en_01
2015-03-11

Summary of content (13 pages)