15 Application examples
Key:
Applications with the PSR-MS60
15.1 Light grid monitoring/automatic start
Two-channel light grid monitoring
Automatic start
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061)
Figure 9 Light grid monitoring/automatic start
15.2 Two-channel control via LPSDO module
Two-channel control
Cross-circuit detection by means of LPSDO module
Automatic start
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061)
Figure 10 Two-channel control via LPSDO module
15.3 Single-channel control via failsafe controller
Single-channel control
Automatic start
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061) if the digital output of the safety-re-
lated controller meets PLe, SIL3 and cross-circuits can
be ruled out
Figure 11 Single-channel control via failsafe PLC
K1/K2 = Contactors