11.4 Configuration
11.4.1 Modbus/RTU
11.4.2 Modbus/TCP
11.4.3 Modbus gateway
Table 11-7
Function Information Web server Display Register
Activation of
Modbus/RTU
The Modbus/RTU protocol is
activated by default, but can be
deactivated by the user.
xxx
Modbus ad-
dress
The default setting is address
1.
xxx
Baud rate The default setting for the RS-
485 interface is 19200 bps.
xxx
Stop bits The default setting for the RS-
485 interface is 1 stop bit.
xxx
Parity The default setting for the RS-
485 interface is even parity.
xxx
Table 11-8 Modbus/TCP
Function Information Web
server
Display Register
Activation of
Modbus/TCP
The Modbus/TCP protocol is
activated by default, but can be
deactivated by the user.
xxx
Table 11-9 Modbus gateway
Function Information Web
server
Display Register
Activation of
the gateway
mode
By default, the gateway mode
is deactivated.
xxx
Modbus gate-
way time-out
The default setting is address
250 ms.