Datasheet

L
H
B
a
b
c
L
H
180
140
a
b
d
68
c
L
H
B
L
H
B
496
PHOENIX CONTACT
Bolt connection terminal blocks are
available either in a single-bolt or double-
bolt design or with a screw/bolt mixed con-
nection. The latter are fitted as high-current
connectors with a terminal sleeve connec-
tion on one side and with a screw set for the
connection of cable lugs on the other. The
dimensions of the various types are shown in
the following drawings and tables.
Secure cable lug connection
Cable lugs are securely connected in
UHV..., HV..., and RT... high-current terminal
blocks using the screw set. Spring washers
are used for screw locking. Cable lugs ac-
cording to DIN 46234, DIN 46235, and
DIN 46237 can be connected. A two-con-
ductor connection is also possible where
one conductor must be connected under
the current bar using a cable lug and the oth-
er must be connected to the current bar. See
diagram below right.
High-current connector with bolt connection
Universal high-current connector
Dimensions in [mm] / [inch]
Type H L W
UHV 25-AS/AS 53 / 2.087 88 / 3.456 26 / 1.024
UHV 25-KH/AS 72 / 2.835 95 / 3.74 26 / 1.024
UHV 25-KH/KH 72 / 2.835 102.5 / 4.035 26 / 1.024
UHV 50-AS/AS 54.5 / 2.146 95 / 3.74 32 / 1.26
UHV 50-KH/AS 78 / 3.071 104 / 4.094 32 / 1.26
UHV 50-KH/KH 78 / 3.071 113.5 / 4.469 32 / 1.26
UHV 95-AS/AS 56 / 2.205 110 / 4.331 40 / 1.575
UHV 95-KH/AS 86 / 3.386 114 / 4.488 40 / 1.575
UHV 95-KH/KH 86 / 3.386 118.5 / 4.665 40 / 1.575
UHV 150-AS/AS 56 / 2.205 110 / 4.331 46 / 1.811
UHV 150-KH/AS 100 / 3.937 119 / 4.685 46 / 1.811
UHV 150-KH/KH 100 / 3.937 128.5 / 5.059 46 / 1.811
UHV 240-AS/AS 58 / 2.283 125 / 4.921 53 / 2.087
UHV 240-KH/AS 105.5 / 4.154 126.5 / 4.980 53 / 2.087
UHV 240-KH/KH 105.5 / 4.154 128.5 / 5.059 53 / 2.087
Secure flat conductor connection
Flat conductors can be reliably and se-
curely connected in UKH and UHV high-
current terminal blocks using the insertion
profile (UKH... EP). This levels out the
prism-shaped terminal sleeve base, there-
by ensuring that the flat conductor is con-
tacted on a large area.
UHV...AS/AS
UHV...KH/AS
UHV...KH/KH
Dimensions for covering hoods and partition plates [mm] / [inch]
Type a b c d
UHV 25 51 / 2.008 82 / 3.228 70 / 2.756 63 / 2.48
UHV 50 57 / 2.244 97 / 3.819 76 / 2.992 68 / 2.677
UHV 95 59 / 2.323 112 / 4.409 84 / 3.307 75 / 2.953
UHV 150 64 / 2.52 125 / 4.921 98 / 3.858 81 / 3.189
UHV 240 64 / 2.52 143 / 5.63 103 / 4.055 87 / 3.425
Suitability of flat conductors for clamping
Conductor Type
Structure
[mm]
Current
[A]
UHV 50-KH/AS
UHV 50-KH/KH
UHV 95-KH/AS
UHV 95-KH/KH
3 x 9 x 0.8 100 X X
6 x 9 x 0.8 160 X
1
) X
4 x 16 x 0.8 200 X
6 x 16 x 0.8 250 X
1
)
10 x 16 x 0.8 400 X
1
)
11 x 21 x 0.8 630
Conductor Type
Structure
[mm]
Current
[A]
UHV 150-KH/AS
UHV 150-KH/KH
UHV 240-KH/AS
UHV 240-KH/KH
3 x 9 x 0.8 100
6 x 9 x 0.8 160 X
4 x 16 x 0.8 200 X X
6 x 16 x 0.8 250 X X
10 x 16 x 0.8 400 X
1
)X
11 x 21 x 0.8 630 X
1
)
1
) Observe nominal current of terminal blocks.
Internal dimensions of terminal
sleeves
Type
Internal dimensions in [mm] / [inch]
a b c
UKH 25 / UHV 25-KH/...
9 / 0.354 – / – 8.5 / 0.335
UKH 50 / UHV 50-KH/...
11 / 0.433 7.5 / 0.295 12 / 0.472
UKH 95 / UHV 95-KH/...
15 / 0.591 11 / 0.433 15 / 0.591
UKH 150 / UHV 150-KH/...
19.5 / 0.768 11 / 0.433 18 / 0.709
UKH 240 / UHV 240-KH/...
24 / 0.945 19 / 0.748 26 / 1.024
Insertion profile
UKH ...EP
RT ... / RTO ...
CLIPLINE complete bolt connection
Ring-lug terminal open style - RTO
Dimensions in [mm] / [inch]
Type H L W
RTO 3 49.9 / 1.965 65 / 2.559 12.2 / 0.480
RTO 5 49.9 / 1.965 65 / 2.559 16.2 / 0.637
RTO 5-T 49.9 / 1.965 90.4 / 3.559 16.2 / 0.637
RTO 8 62.2 / 2.449 84 / 3.307 20.2 / 0.795
CLIPLINE complete bolt connection
Ring-lug terminal - RT
Dimensions in [mm] / [inch]
Type H L W
RT 3 51 / 2.007 65 / 2.559 12.2 / 0.480
RT 5 51 / 2.007 65 / 2.559 16.2 / 0.637
RT 5-T 51 / 2.007 90.4 / 3.559 16.2 / 0.637
RT 8 63.8 / 2.511 84 / 3.307 20.2 / 0.795
Terminal blocks
RBO and RSC bolt connection terminal blocks