Datasheet


Technical data Technical data
Max. electrical data I
max.
[A] U
max.
[V] Max. Ø [mm²] AWG (UL) I
max.
[A] U
max.
[V] Max. Ø [mm²] AWG (UL)
24 400
1
) 0.5 - 2.5 - 24 400
1
) 0.5 - 2.5 -
Rated data IEC UL CSA IEC/
EN60079-7
IEC UL CSA IEC/
EN60079-7
Rated voltage [V] 400
1
) 300 - - 400
1
) 300 - -
Nominal current / cross section [A] / [mm²] 24 / 2.5 10 - - 24 / 2.5 10 - -
Rated cross section [mm²] 6 - - - 6 - - -
Cross section range AWG 20 - 14 - - - 20 - 14 - - -
Connection capacity Solid Stranded Ferrule Solid Stranded Ferrule
without/with plastic sleeve without/with plastic sleeve
1 conductor [mm²] - 0.5 - 2.5 - - - 0.5 - 2.5 - -
General data
Tightening torque: test socket screw [Nm] 0.5 - 0.6 0.5 - 0.6
Insulating material PA PA
Inflammability class according to UL 94 V0 V0
Ordering data Ordering data
Description Color Type Order No.
Pcs. /
Pkt.
Type Order No.
Pcs. /
Pkt.
Test plug gray FTPR-2/4 3001681 1 FTP-2/4 3001706 1
5-pos. gray FTPR-2/5 3001683 1 FTP-2/5 3001707 1
6-pos. gray FTPR-2/6 3001684 1 FTP-2/6 3001708 1
7-pos. gray FTPR-2/7 3001685 1 FTP-2/7 3001709 1
8-pos. gray FTPR-2/8 3001686 1 FTP-2/8 3001710 1
9-pos. gray FTPR-2/9 3001687 1 FTP-2/9 3001711 1
10-pos. gray FTPR-2/10 3001688 1 FTP-2/10 3001712 1
11-pos. gray FTPR-2/11 3001689 1 FTP-2/11 3001713 1
12-pos. gray FTPR-2/12 3001690 1 FTP-2/12 3001714 1
13-pos. gray FTPR-2/13 3001691 1 FTP-2/13 3001715 1
14 pos. gray FTPR-2/14 3001692 1 FTP-2/14 3001716 1
15-pos. gray FTPR-2/15 3001693 1 FTP-2/15 3001717 1
16-pos. gray FTPR-2/16 3001694 1 FTP-2/16 3001719 1
17-pos. gray FTPR-2/17 3001696 1 FTP-2/17 3001720 1
18-pos. gray FTPR-2/18 3001697 1 FTP-2/18 3001722 1
19 pos. gray FTPR-2/19 3001698 1 FTP-2/19 3001723 1
20 pos. gray FTPR-2/20 3001699 1 FTP-2/20 3001724 1
21 pos. gray FTPR-2/21 3001700 1 FTP-2/21 3001725 1
22 pos. gray FTPR-2/22 3001701 1 FTP-2/22 3001726 1
23-pos. gray FTPR-2/23 3001702 1 FTP-2/23 3001727 1
24-pos. gray FTPR-2/24 3001703 1 FTP-2/24 3001728 1
25 pos. gray FTPR-2/25 3001704 1 FTP-2/25 3001729 1
Accessories Accessories
Fork-type cable lug, insulated, according to UL red C-FCI 1,5/M3 3240032 100 C-FCI 1,5/M3 3240032 100
2.5mm² blue C-FCI 2,5/M3 3240037 100 C-FCI 2,5/M3 3240037 100
Ring cable lug, insulated, according to UL red C-RCI 1,5/M3 3240016 100 C-RCI 1,5/M3 3240016 100
2.5mm² blue C-RCI 2,5/M3 3240021 100 C-RCI 2,5/M3 3240021 100
Marking UC-TM 8, UCT-TM 8, ZB 8 or TMT(EX9,5)R
(see Catalog 5)
UC-TM 8, UCT-TM 8, ZB 8 or TMT(EX9,5)R
(see Catalog 5)
534
PHOENIX CONTACT
Sector-specific solutions
Solutions for energy technology
24A, test plug with twist grip, 4 mm test
sockets
24A, test plug without twist grip, 4 mm test
socket
The test plugs can be easily
configured and ordered with just a
click of the mouse in the product
area on our website at
phoenixcontact.net/products.
To order via fax or e-mail, please use
the ordering data as shown in the
ordering example on the following
page
Notes:
1
) Rated surge voltage: 4 kV.
FTPR ... and FTP ... test plug, multi-
position, freely configurable contact
tabs