Technical data and ordering data
108366_en_01 PHOENIX CONTACT 61 / 69
Switching distances: actuation position A, B when traveling in X direction
Switch-on distance, typical 13 mm, typical
Assured operation distance S
ao
10 mm (position A)
9 mm (position B)
Switching hysteresis 1 mm, minimum
2 mm, typical
Assured release distance S
ar
20 mm, maximum
Repeat accuracy ≤10 %
Additional values Table 3-1 “Minimum distances and switching distances” in Section “Positioning and distances” on
page 26.
Switching distances: actuation position C, D when traveling in X direction
Switch-on distance, typical 7 mm, typical
Assured operation distance S
ao
Position C:
3 mm
Position D:
2 mm
Switching hysteresis 1 mm, minimum
2 mm, typical
Assured release distance S
ar
17 mm, maximum
Repeat accuracy ≤10 %
Additional values Table 3-1 “Minimum distances and switching distances” in Section “Positioning and distances” on
page 26.