PSR-CT
62 / 69
PHOENIX CONTACT 108366_en_01
10.1.4 Safety-related characteristics
10.1.5 Interface types according to ZVEI classification
Safety outputs FO1A, FO1B
10.1.6 Approvals
Safety characteristics according to EN ISO 13849-1:2015
Category 4
Performance level e
Duration of use 240 months
Safety-related characteristics for IEC 61508
SIL 3
PFH
D
6 x 10
-10
1/h
Source/
drain
Interface
type
Additional
measure
Source/
drain
Suitable
interface
type
Suitable
interface
type
Source C2 M Drain C1 C2
Additional
measure M
– Outputs are not types according to IEC 61131-2