INPUT GAIN (SENS) CH 1/2, 3/4, 5/6
Used to adjust the input sensitivity to match the input level signal on the channels.
Continuously variable from 0.4V to 10V. Adjust this with the help of a DMM and a test
signal or an Oscilloscope. See System Tuning section for basic setup instructions.
CROSSOVER (X-OVER) CH 1/2, 3/4, 5/6
High Pass Filter (HPF): When set, activates a highpass crossover for the channels.
Continuously variable from 40Hz to 500Hz using the FREQ dial.
Full Range (FULL): Select FULL to amplify a full range signal.
Low Pass Filter (LPF): When set, activates a low pass crossover for the channels.
Continuously variable from 40Hz to 500Hz using the FREQ dial.
INPUTS (F/R CHs, SUB CH)
If you are using RCA or high level signal from an aftermarket head unit, select UNBAL. If
you are using high level from a OEM factory source unit or factory amplier select BAL.
INPUT CONFIG (4CH / 6CH)
Input signal selectable for 4 or 6 channels. If only 4 channels of input signal are
available, select 4CH to allow signal to split to CH 5+6. Select 6CH if 6 channels
of input are being used.
INPUT (CH1-6)
Connect preamp signal cables (RCA) from the source unit to these terminals.
Use of 4 or 6 channels of input signal selectable with INPUT CONFIG switch.