PHOENIX CONTACT 7278_en_01
Minimum transmission length, including 3 dB system reserve, when using
single-mode
36 km glass fiber with F-G 9/125 0,36 dB/km
32 km glass fiber with F-G 9/125 0,4 dB/km
26 km glass fiber with F-G 9/125 0,5 dB/km
Maximum transmission power single-mode -8 dBm
Minimum transmission power single-mode -15 dBm
Minimum recierver sensitivity single-mode -31 dBm
Maximum overrange single-mode -7 dBm
Transmission speed 100 Mbps
V.24 (RS-232) communication interface
Number 1
Connection format Mini-DIN female connector on the switch
Floating alarm contact
Voltage 24 V DC
Current carriyng capacity 100 mA, maximum
Interfaces (Continued)
Mechanical Tests
Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse
Storage/transport: 50g, 11 ms period, half-sine shock pulse
Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, criterion 3
Free fall according to IEC 60068-2-32 1 m
Conformance With EMC Directives
Developed according to IEC 61000-6.2
Noise emission according to EN55022: 1998
+ A1: 2000 + A2: 2003 (interference voltage)
Class A (industrial applications)
Noise emission according to EN55011: 1998
+ A1: 1999 + A2: 2002 (electromagnetic interference)
Class A (industrial applications)
Noise immunity according to EN61000-4-2 (IEC1000-4-2) (ESD)
Contact discharge:
Air discharge:
Indirect discharge:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B
Test intensity 3, criterion B
Test intensity 2, criterion B
Noise immunity according to EN61000-4-3 (IEC1000-4-3) (electromagnetic
fields)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Noise immunity according to EN61000-4-4 (IEC1000-4-4) (burst)
Data lines:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B
Test intensity 3, criterion B
Noise immunity according to EN61000-4-5 (IEC1000-4-5) (surge)
Data lines:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B
Test intensity 1, criterion B
Noise immunity according to EN61000-4-6 (IEC1000-4-6) (conducted) Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Differences Between This Version and Previous Versions
Version 00: First version
Version 01: LM-E switches and functions of the actual firmware version added