1.3.3 V.24 (RS-232) Interface for External Management
The 6-pos. Mini-DIN female connector provides a serial interface to connect a local
management station. Use the "PRG CAB MINI DIN" programming cable
(Order No. 2760611). It can be used to connect a VT100 terminal or a PC with
corresponding terminal emulation to the management interface (for an appropriate cable,
please refer to "Ordering Data" on page 6-2). Set the following transmission parameters:
Figure 1-8 Transmission parameters and assignment of the V.24 (RS-232) interface
1.3.4 Grounding
All Factory Line devices must be grounded so that any possible interference is shielded
from the data telegram and discharged to ground potential.
A wire of at least 2.5 mm
2
must be used for grounding. When mounting on a DIN rail, the
DIN rail must be connected with protective earth ground using grounding terminal blocks.
The module is connected to protective earth ground via a metal clip on the rear of the
housing.
Bits per second 38400
Data bits 8
Parity None
Stop bits 1
Flow control None
Grounding protects people and machines against hazardous voltages. To avoid these
dangers, correct installation, taking the local conditions into account, is vital.
Option: In an environment particularly prone to EMI, noise immunity can be increased
by an additional low-impedance connection to functional earth ground via terminal 7
("Assignment of the COMBICON Connector" on page 1-6).