Operating Instructions and Installation Instructions
Pursuant to current regulations on the safety of electrical equipment, you must contact your dealer or a qualied electrician for all and any work
connected with installation, maintenance or servicing that involves access to electrical parts.
Cladding
• Having completed assembly of the stove and installed any external room thermostat, proceed with assembly of the stove cladding, referring to the
ceramic cladding instruction booklet provided with the stove.
5.0 INSTALLATION
• Thanks to Piazzetta technology and R&D, this pellet stove offers the
advantages of the “Multifuoco system”, a system EXCLUSIVE to and
PATENTED by Gruppo Piazzetta S.p.A., a true innovation in the eld of
pellet stoves.
• The “Multifuoco system” revolutionises all methods of heat circulation
currently in use in pellet stoves: the heat produced by the rebox is
not only circulated from the lower part of the stove into the room,
but hot air can also be ducted via Ø 3” / (Ø 75 mm) exible pipes to
adjoining rooms (Fig. 27).
This exclusive oor-standing heat distribution system offers notable
advantages: even spread of temperatures (Fig. 26).
The hot air produced is propelled by a fan and distributed via the grille
in the bottom front of the stove.
• This grille is tted with an adjustable ap.
• To direct the outow of hot air as required, adjust the angle of the ap
by pressing on the part of it that projects (Fig. 28).
Instructions for ducting the hot air
• The fan kit, which propels hot air into the room, can be tted with a
Y-element which effectively allows the hot air ow to be doubled up,
directing it via a exible pipe also to the rear of the stove, from where
it can then be ducted to adjoining rooms.
• Some examples of possible installation are given below as well as
examples of how to duct the hot air in order to heat other rooms.
Such examples are given purely for demonstration purposes; best
efciency can be obtained using Ø 3” / (Ø 75 mm) coated ducting
in accordance with instructions given in the sub-paragraph “Wall
and oor ducting” and with a maximum total exible pipe length of
32.8’ / (10 m). This length consists of the sum of the single lengths
of exible pipes.
a It is of fundamental importance that when ducting heat from
the rear of the stove, the outlet vents near the stove or the
Y-element must not be closed in order to avoid overheating.
In cases where only one rear outlet from the fan is envisaged,
the outlet vent must always be kept open.
• The examples show the ducting. Each diagram gives just one example
of the many possible solutions.
DT2012361-00
5.1 MULTIFUOCO SYSTEM
Fig. 26
Fig. 27
Fig. 28
H07031310 / DT2002112 – 00
23
English
DT2010116-02
DT2010071-05
DT2030163-00
DT2030162-00