Operating Instructions and Installation Instructions
DT2010251-03
6.12 MULTICOMFORT
The pellet stove is tted with the Multicomfort function. This works in conjunction with the Multifuoco ventilation system to improve heat distribution.
It allows the room temperature to be read from the stove or from the remote control, so that the Multifuoco settings can be varied according to the
requirements of the rooms to be heated.
If the airow from your stove has been ducted to other rooms you may read the temperature in the room where the stove is installed or in the room
where the remote control is situated.
Example: your stove is installed in a small room and you are ducting the heat only from the rear of the stove (see solution 1 under the paragraph
“MULTIFUOCO SYSTEM”). You can position the remote control in the room to where the hot air has been ducted and set the required temperature
from this room. To carry out the necessary settings see the MULTICOMFORT menu.
MULTICOMFORT
This function is used to choose the sensor for reading the room temperature: from the stove or from the remote control. To make the
most of the Multifuoco fan functions read the paragraphs MULTIFUOCO SYSTEM and MULTICOMFORT OPERATION.
Function Action Display
Select the
MULTICOMFORT
menu
Press the MENU key, then using the SELECT MENU key select the
MULTICOMFORT menu.
Conrm by pressing the SET key.
MULT I
COMFORT
SELECT
RRC
SELECT
STOVE
1
1
1
Select the REMOTE
CONTROL SENSOR
(SELECT RRC) or
STOVE (SELECT
STOVE)
Press the SELECT MENU key and select “SELECT RRC” to read the room
temperature from the remote control or “SELECT STOVE” to read the
room temperature from the stove. Conrm by pressing the SET key. After
conrmation the readout function enabled (FUNCTION ENGAGED) will
appear on the display and the remote control will automatically return to
the initial display.
MULT I
COMFORT
SELECT
RRC
SELECT
STOVE
1
1
1
MULT I
COMFORT
SELECT
RRC
SELECT
STOVE
1
1
1
DT2040070-04
DT2012431-00
6.13 ENERGY SAVING
When the ENERGY SAVING mode is enabled, automatic startup/ignition and shutdown of the stove is activated at temperature values set by the user
through the STOP and START functions.
The temperature value selected 2, 4 or 6 °F (1, 2 or 3 °C ) in STOP function or selected in START function with negative values -2, -4 or -6 °F (-1, -2
or -3 °C) denes the value from which the Energy Saving mode will either increment or deduct from the room temperature set.
The operating principle is as follows:
when the room temperature measured by the room sensor or the remote control reaches the temperature value programmed by the user, the stove
automatically goes to power level 1 (readout “OK” on the display).
If the room temperature continues to rise with operation at power level 1 up to the value set on the STOP function (e.g. +4 °F / +2 °C compared to
the programmed temperature), the stove shuts down and goes into the stand-by mode.
H07031310 / DT2002112 – 00
45