Operating Instructions and Installation Instructions

DT2010428-03
7.3 CLEANING THE FIREBOX
A
A DETAIL
ECCENTRIC CLAMP
BOTTOM RESTRAINT
TABS
INTERNAL BAFFLE
Fig. 65
Once a week clean the rebox as follows.
- Remove the grate bafe and draw out the grate.
- Turn the eccentric clamps to free the internal bafe.
- Lift the bafe slightly, gripping it by the two outer tabs to free it at the
bottom and then turn it, bringing the bottom outwards, and remove.
- Using a vacuum cleaner remove the ash from the rebox.
- After having thoroughly cleaned the rebox, remount the internal
bafe proceeding in the reverse order to above.
- Ensure that the tabs are properly inserted into the relative notches
in the sides of the rebox and secure the bafe by turning the two
eccentric clamps.
- Replace the grate, pushing it to the left and the grate bafe.
a This type of cleaning requires a vacuum cleaner suitable for
holding ash.
a To dispose of the ashes, refer to the paragraph “DISPOSAL OF
ASHES”.
Once a year clean the smoke chamber as follows:
- remove the screw that secures the smoke chamber cover (use the
provided wrench), then lift it slightly and take it out by pulling it
towards you ((Fig. 66 - 67);
- use a vacuum cleaner to remove any ash and carbon deposits which
can accumulate in the chamber, taking care not to damage the blades
of the fan (Fig. 68);
- check the hole inside the smoke chamber on the left side (leading to
the device for measuring the vacuum) for dust and ash and clean if
necessary;
- after thorough cleaning, change the gasket and replace the smoke
chamber closing element.
Fig. 66
Fig. 67
Fig. 68
DT2010127-03
7.4 CLEANING THE SMOKE CHAMBER
H07031310 / DT2002112 – 00
59
English
DT2030725-00
DT2032880-00
DT2032881-00
DT2032882-00