Datasheet

SW TICHINGTHESMARTWAY
MS-324-4
Remarks
When mounted onto ferromagnetic parts
switching distance of
may reduce.
Electromagnetical influences and magnetic
fields may change the switching behaviour of
the sensor.
MS-324-4
Matching actuator MSM-324 available as well.
Only non-ferromagnetic screws to be used for
mounting.
MS-324-4
Form C Reed Sensor Flatpack
Test coil 324TC-
Test programs
Test Procedure of final Reed Sensor Test Parameters
Material Information
AT range Test program
2 MS-324-4 2= -
3 MS-324-4 3= -
4 MS-324-4 4= -
Material
Colour
Housing ABS black
Cable UL 1007/1569, AWG 26 , 4 mm stripped and tinned COM: black, NO: red, NC: brown
Potting compound Epoxy black
Test Coil placed in vertical position
Reed Sensor aligns with bottom line
Reed Sensor pushed into opposite corner
of Test Coil
PIC Proximity Instrumentation Controls
Kontaktbauelemente GmbH
Phone +49 911 99 59 06-0
Fax +49 911 99 59 06-99
Rev.: 1.4
ms3244_ds_e_1.4
Page 2 of 2 Nibelungenstr. 5 A
90530 Wendelstein, Germany
info@pic-gmbh.com
www.pic-gmbh.com