Trapmate Mini LED Indicators:
Power Up w/Acknowledgement (PASS)----> Blinking GREEN LED ve times, pause, rapid ashing GREEN 5s
Power Up w/Acknowledgement (FAIL)----> Blinking GREEN LED ve times, pause, rapid ashing RED 5s
Power Down -----------------------------------> Blinking RED LED ve times
Trigger ------------------------------------------> Blinking GREEN LED two times
Reset --------------------------------------------> Fast Blinking RED LED
While unit is ON and not being triggered a status LED will ash GREEN every 10 seconds.
The Trapmate Mini is equipped with a multi-color LED indicator for feedback status to the user.
Below is a chart of the status indicators:
Trapmate Mini Accelerometer Sensitivity Adjustment:
When the unit is ON, hold the function button for 3-6 seconds until the blinking RED LED changes to a RED
& GREEN alternating pattern. Once in program mode, push the button (slowly, press for about 1 second then
release). The GREEN LED will ash for each button click in program mode. Click the button 1-10 times and
then let the unit sit for 10 seconds. The GREEN LED will then ash X number of times to indicate how many
clicks were processed and set as the new sensitivity setting. The unit then will perform a connection back to the
Skyhawk HUB that will report the new setting to the Skyhawk CE application.
Accelerometer Sensitivity Note:
Sensors are shipped with a default maximum sensitivity of 10, unless otherwise noted. This will help ensure
activation in multi-catch deployments or snap trap deployments inside cardboard boxes or rodent stations. High
sensitivity can lead to false alerts from external environmental factors such as rain, hail or extraneous vibrations.
If false alerts arise, the vibration sensitivity can be reduced using the procedure above. The sensor can also be used
in reed switch(magnet pull)mode to detect physical displacement from snap trap closures. Using both sensors can
be a useful deployment in live animal trap cage deployments. The cage door closing event can be positively moni-
tored with the reed switch sensor through a magnet pull. Animal captures can be conrmed with a high sensitivity
vibration setting to conrm the animal capture. Vibrations alerts that are not preceded by a door closure alert can
be disregarded.