PIT js2 Control and signal devices Operating Manual21130EN05
Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries.
Content Introduction Validity of documentation Retaining the documentation Definition of symbols 4 4 4 4 For your safety 5 Intended use 5 Device description 5 Function description 6 Wiring Assignment Connection to evaluation device Dimensions in mm PIT js2 PIT js holder 6 6 7 9 9 10 Technical Details Safety characteristic data 10 11 Order reference Product Accessories 11 11 11 Operating Manual PIT js2 21130EN05 3
PIT js2 Introduction Validity of documentation This documentation is valid for the product PIT js2. It is valid until new documentation is published. This documentation is valid for PIT js2 from the date of manufacture 201408. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Retaining the documentation This documentation is intended for instruction and should be retained for future reference.
PIT js2 INFORMATION This gives advice on applications and provides information on special fea tures. For your safety } The unit may only be installed and commissioned by personnel who are familiar with both these instructions and the current regulations for health and safety at work and ac cident prevention. Ensure VDE and local regulations are met, especially those relating to protective measures.
PIT js2 } The contacts are connected by a coiled cable with an open end. Function description An enabling signal is generated in conjunction with a twohand monitoring module by simul taneously pressing the ACT1 and ACT2 pushbuttons. This overrides the safety function of the movable guards. Authorised operating personnel then can enter the danger zone to monitor work processes. Releasing one or both pushbuttons ACT1 and ACT2 will interrupt the enabling signal.
PIT js2 Connection to evaluation device P2HZ X1 P2HZ X1P S11 P2HZ X1.10P S12 PNOZ e2.
PIT js2 PSS SafetyBUS p (with standard function block SB059) T0 T1.2 T1.4 T1 T2.2 T2.
PIT js2 Dimensions in mm PIT js2 60 ACT1 RESET 74 334 Operating Manual PIT js2 21130EN05 9
PIT js2 PIT js holder 150 6 30 44 7 312.7 6 5 70 83 Technical Details General Approvals Electrical data Supply voltage Voltage Kind Max.
PIT js2 Relay outputs Utilisation category DC 1 at Environmental data Ambient temperature Temperature range Protection type Housing Mechanical data Cable length L1 Cable insulation material K1 Conductor cross section K1 Material Housing Dimensions Height Width Depth Weight 24 V 10 55 °C IP50 5,00 m PUR 0,14 mm² – 334,0 mm 74,0 mm 60,0 mm 764 g Safety characteristic data Safety characteristic data B10d in accordance with EN ISO 138491 and EN IEC 62061 Lambdad/Lambda in accordance with EN IEC 62061 2
Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 Spain +55 11 97569-2804 Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30 +52 55 5572 1300 Belgium, Luxembourg The Netherlands USA (toll-free) +32 9 3217575 +31 347 320477 +1 877-PILZUSA (745-9872) France Turkey +33 3 88104000 +90 216 5775552 Asia Germany United Kingdom China +49 711 3409-444 +44 1536 462203 +86 21 60880878-216 Ireland Japan +353 21 480