Installation
CAUTION!
The unit's properties may be affected if installed in an environment contain-
ing electrically or magnetically conductive material. Please check the oper-
ating distances and the assured release distance.
} The safety switch and actuator should be installed opposite each other in parallel.
} Safety switches and actuators should be permanently secured using M5 safety screws
with a flat head (e.g. M5 cheese-head or pan head screws).
} Protect the actuator from contamination.
} Torque setting: Please note the information provided under Technical details [ 18].
} The distance between two safety switches must be maintained (see Technical
details [ 18]).
} Make sure that the safety switch and actuator cannot be used as an end stop.
Procedure:
Fig.: Sensing faces on the sensor
1. Drill holes (for M5 screws) in the mounting surface to secure the actuator and sensor
(see Dimensions in mm [ 18]).
2. Use a screw to fix the sensor to the mounting surface.
Make sure that the sensor marking that is be used for operation can be operated using
the actuator from the right side.
3. Do not fully tighten the second screw on the safety switch.
4. Use a screw to fix the actuator to the mounting surface.
Make sure that the actuator with the printed side points towards the marking on the
sensor.
5. Do not fully tighten the second screw on the actuator.
6. Align the safety switch and tighten the screws.
7. Align the actuator and tighten the screws.