User Manual
PSEN cs2.1p
Operating Manual PSEN cs2.1p
1003268-EN-07
19
Electrical data
Max. cable capacitance at the safety outputs
No-load, PNOZ with relay contacts 40 nF
PNOZmulti, PNOZelog, PSS 70 nF
No-load current 50 mA
Inputs
Number 2
Voltage at inputs 24 V DC
Input current range 5 mA
Max. overall cable resistance Rlmax
Single-channel at UB DC 1000 Ohm
Semiconductor outputs
OSSD safety outputs 2
Signal outputs 1
Switching current per output 500 mA
Breaking capacity per output 12 W
Potential isolation from system voltage No
Short circuit-proof Yes
Residual current at outputs 10 µA
Voltage drop at OSSDs 3,5 V
Lowest operating current 0 mA
Utilisation category in accordance with EN 60947-1 DC-12
Times
Test pulse duration, safety outputs 450 µs
Switch-on delay
after UB is applied 1 s
Inputs typ. 13 ms
Inputs max. 20 ms
Actuator typ. 45 ms
Actuator max. 100 ms
Delay-on de-energisation
Inputs typ. 15 ms
Inputs max. 20 ms
Actuator typ. 30 ms
Actuator max. 260 ms
Supply interruption before de-energisation 20 ms
Simultaneity, channel 1 and 2 ∞
Environmental data
Ambient temperature
In accordance with the standard EN 60068-2-14
Temperature range -25 - 70 °C
Storage temperature
In accordance with the standard EN 60068-2-1/-2
Climatic suitability
In accordance with the standard EN 60068-2-78
Humidity 93 % r. h. at 40 °C