User Manual

PSEN cs2.1p
Operating Manual PSEN cs2.1p
1003268-EN-07
7
For your safety
WARNING!
Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.
You should prevent any possibility of the interlocking device being
manipulated through the use of a spare actuator.
Keep the spare actuator in a safe place and protect it from unauthor-
ised access.
If spare actuators are used, these must be installed as described in
Installation [ 15].
} Do not remove the connector's protective cap until you are just about to connect the
unit. This will prevent potential contamination.
Unit features
} Transponder technology for presence detection (safety function)
} Pilz coding type: fully coded
} Dual-channel operation
} 2 safety inputs for series connection of multiple safety switches
} 2 safety outputs
} 1 signal output
} LED display for:
State of the actuator
State of the inputs
Supply voltage/fault
} 4 directions of actuation
Function description
The safety outputs may have a high or low signal, depending on the position of the actuator
and the signal status of the inputs.
In a safe condition there is a low signal at the safety outputs.
Electrical states of the inputs and outputs (when switch is ready for operation:
Power / Fault LED is green):
Actuator in
the re-
sponse
range
Safety input
S11
Safety input
S21
Safety out-
put 12
Safety out-
put 22
Signal out-
put Y32
Yes High High High High High
Yes Low Low Low Low High
No X X Low Low Low