Brochure

36(1bFVS 36(1bFVS 36(1bFVS
32
3URGXFWJURXS&RGHGVDIHW\VZLWFK36(1FRGH
Coded safety switch PSENcode
The non-contact, coded safety switch PSENcode is used both for monitoring the position of guards
in accordance with EN 60947-5-3 and simple position monitoring.
Highest level of manipulation protection
in the smallest space
With PSENcode you have the smallest, coded safety
switch with integrated evaluation and built-in manipulation
protection thanks to RFID technology.
The unique fully coded version of PSENcode has
the highest level of manipulation protection: the sensor
will only accept a single actuator (key lock principle).
PSENcs2.13p
Type code for PSENcode
Product area
Pilz SENsors
Coding/design Additional functions Connection type
Product range
cs – PSENcode
1.1
2.1
2.2
3.1
4.1
4.2
5.1
6.1
6.2
Coded,
large design
Fully coded,
large design
Unique, fully coded,
large design
Coded,
compact design
Fully coded,
compact design
Unique, fully coded,
compact design
Coded,
slimline design
Fully coded,
slimline design
Unique, fully coded,
slimline design
_
1
3
9
Without ATEX
With magnetic latching
With ATEX
With max.
three actuators
a
b
n
p
M12
ō Cable, 5m
1)
ō Cable, 10m
1)
ō Connector, M12, 5-pin
ō Connector, M12, 8-pin
(large design)
1)
ō Connector, M8, 8-pin
(compact, slimline design)
1)
ō Connector, M12, 8-pin
(compact, slimline design)
1)
Operation
ō Non-contact,
coded
ō Transponder
(RFID)
ō With safe
semiconductor
outputs

6HULHVFRQQHFWLRQLQWHJUDOLQVHQVRU6''FDSDEOHDVRIYHUVLRQ
The coded PSENcode is accepted by other PSENcode
actuators. The fully coded PSENcode only accepts one
actuator. In contrast to the unique, fully coded safety
switch, it’s possible to teach-in a new actuator on
the switch retrospectively.
Position monitoring with dierentiation
When several positions need to be monitored and also
distinguished safely, PSENcode x.19n is the right choice
(from page 36).
Safety switches

Summary of content (8 pages)