User Manual

PSEN cs3.1n
Operating Manual PSEN cs3.1n
22172-EN-03
17
Each error code is indicated by three short flashes of the "Input" or "Safety Gate" LED.
After a longer pause, the LED will then flash at one second intervals. The number of LED
flashes corresponds to a digit in the error code. The error code can consist of up to 3 digits.
The digits are separated by a longer period without flashing. The entire sequence is con-
stantly repeated.
Number of flashes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Decimal error code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0
Example:
Error code 1,4,1:
Flash frequency of the "Safety Gate" or "Input" LED
I IV
III
II
V
Meaning of flash frequency:
Flash frequency Meaning
I 3 times, short Code for error message
II Once, for one second each Code for 1st digit
III 4 times, for one second each Code for 2nd digit
IV Once, for one second each Code for 3rd digit
V 3 times, short Code for error message repeated
Table of error codes
Error code
Decimal Number of flashes Description Remedy
1.4.1 3x short – 1x long – 4x
long – 1x long – 3x short
Wiring error Rectify wiring error
1.12 3x short – 1x long – 12x
long – 3x short
Wiring error Rectify wiring error
1.13 3x short – 1x long – 12x
long – 3x short
Wiring error Rectify wiring error
14 3x short – 14x long – 3x
short
Wiring error Rectify wiring error
15 3x short – 15x long – 3x
short
Wiring error Rectify wiring error
Other flashing codes signal an internal error. Remedy: Change device.