Technical Catalogue Relays PNOZ Version 2016-09 } Configuration guide } Safety relays PNOZ X } Safety relays PNOZsigma
Contents Introduction Relays for functional safety Selection guide Safety relays PNOZ X Safety relays PNOZsigma 6 10 546 2016-09 2
Introduction Introduction Safety relays PNOZ monitor safety functions such as E-STOP, safety gate, light grid, twohand control and much more. Safety relays from the product range PNOZ X are proven through their reliability and robustness and have developed a wide application range in the most varied of safety applications. PNOZ is the most widely used safety relay in the world. One PNOZ is used per safety function.
Relays for functional safety Relays for functional safety Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Contents Page Selection guide 6 Safety relays PNOZ X 10 Safety relays PNOZsigma 546 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Selection guide PNOZ X Selection guide PNOZ X Type Application Performance Level (PL) EN ISO 13849-1 Safety Integrity Level (SIL) CL – Claim limit in accordance with IEC 62061 Output contacts Safety-related Not safety-related Housing width in mm PNOZ X1P ♦ ♦ e 3 3 - 1 - 22.5 PNOZ X2P ♦ ♦ e 3 2 - - - 22.5 PNOZ X2.1VP ♦ ♦ d 3 2 2 - 1 22.5 PNOZ X2.3P ♦ ♦ e 3 3 - - - 22.5 PNOZ X2.7P ♦ ♦ ♦ e 3 3 - 1 - 22.5 PNOZ X2.
Relays for functional safety Selection guide PNOZ X Safety Integrity Level (SIL) CL – Claim limit in accordance with IEC 62061 Output contacts Type Application Performance Level (PL) EN ISO 13849-1 PZE X5P Contact expansion e 3 5 - - 2 45.0 PZE 9P Contact expansion e 3 8 - 1 - 90.0 e 3 3 - 1 5 90.0 e 3 2 - 1 1 45.
Relays for functional safety Selection guide PNOZsigma PNOZsigma Type Application Performance Level (PL) EN ISO 13849-1 Safety Integrity Output contacts Level (SIL) CL – Claim limit in accordance with IEC 62061 Safety-related Not safety-related Universal power supply 48 … 240 VAC/DC Housing width in mm PNOZ s1 ♦ ♦ c 2 2 - - 1 12.5 PNOZ s2 ♦ ♦ e 3 3 - 1 1 17.5 PNOZ s3 ♦ ♦ ♦ e 3 2 - - 1 17.5 PNOZ s4 ♦ ♦ ♦ e 3 3 - 1 1 ♦ 22.5 PNOZ s4.
Relays for functional safety Selection guide PNOZsigma Safety Integrity Output contacts Level (SIL) CL – Claim limit in accordance with IEC 62061 Safety-related Type Application Performance Level (PL) EN ISO 13849-1 PNOZ s30 Safe speed and standstill monitor e 3 Safety Integrity Semiconductor outputs Level (SIL) CL – Claim limit in 1-pin accordance with IEC 2-pin 62061 3 ♦ ♦ 2 Not safety-related - 2 4 Universal power supply 24 … Housing width 240 VAC/DC in mm ♦ 45.
Relays for functional safety Safety relays PNOZ X Safety relays PNOZ X Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X Contents Page PNOZ X1P 12 PNOZ X2P 23 PNOZ X2.1VP 41 PNOZ X2.3P 54 PNOZ X2.7P 66 PNOZ X2.8P 88 PNOZ X2.9P 112 PNOZ X3P 126 PNOZ X3.10P 147 PNOZ X7P 162 PNOZ X8P 179 PNOZ X9P 213 PNOZ X10.11P 237 PNOZ X11P 251 PNOZ XV1P 273 PNOZ XV2P 292 PNOZ XV2.1P 318 PNOZ XV3P 345 PNOZ XV3.1P 372 PZE X4P 409 PZE X4.
Relays for functional safety Safety relays PNOZ X PNOZ X1P PNOZ X1P Unit features } } } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous Connection options for: – E-STOP pushbutton – Safety gate limit switch – Start button LED display for: – Supply voltage – Switch status of the safety contacts } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Pilz GmbH
Relays for functional safety Safety relays PNOZ X PNOZ X1P Block diagram/terminal configuration *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X1P provides a safety-oriented interruption of a safety circuit. When the supply voltage is applied via the E-STOP pushbutton, the “POWER” LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ X1P Timing diagram [1] [2] POWER/Input Legend } Power/Input: Supply voltage/input circuit } Start: Start circuit } Output safe: Safety contacts } Output aux: Auxiliary contact } [1]: Automatic start } [2]: Manual start } a: Input circuit closes before start circuit } b: Start circuit closes before input circuit } t1: Switch-on delay } t2: Delay-on de-energisation } t3: Recovery time Installation } The unit should be installed
Relays for functional safety Safety relays PNOZ X PNOZ X1P Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24, 33-34 are safety contacts; output 41-42 is an auxiliary contact (e.g. for display). } Auxiliary contact 41-42 should not be used for safety circuits! } Do not connect undesignated terminals. } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 17]). } Calculation of the max.
Relays for functional safety Safety relays PNOZ X PNOZ X1P Start circuit Automatic start Manual start E-STOP/safety gate S3 Y1 Y2 Feedback loop Automatic start Manual start Contacts from external contactors Y1 Y2 13 (23, 33) 14 (24 ,34) S3 K5 K6 K5 L1 N K6 Legend } S1: E-STOP/safety gate switch } S3: Start button } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X1P Technical details General 777100 787100 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 777100 787100 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 1,5 W 160 % 100 % 1,5 W 160 % 100 % 1,2 A 2,5 ms 1,2 A 2,5 ms Inputs 777100 787100 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Max.
Relays for functional safety Safety relays PNOZ X PNOZ X1P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X1P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ X1P Times 777100 787100 Supply interruption before de-energisation 20 ms 20 ms Environmental data 777100 787100 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X1P Mechanical data Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Strip
Relays for functional safety Safety relays PNOZ X PNOZ X1P Service life graph Switching current (A) The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible.
Relays for functional safety Safety relays PNOZ X PNOZ X2P PNOZ X2P Unit features } Positive-guided relay outputs: – } } 2 safety contacts (N/O), instantaneous Connection options for: – E-STOP pushbutton – Safety gate limit switch – Start button LED display for: – Supply voltage – Switch status of the safety contacts } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Block diagram/terminal configuration Type: 24 V AC/DC } UB: 24 VAC/DC; Order no. 777303, 787303 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Type: 48-240 V AC/DC } UB: 48-240 VAC/DC; Order no. 777307, 787307 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X2P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ X2P } Automatic start: Unit is active once the input circuit has been closed. } Manual start: Unit is active once the input circuit and the start circuit are closed. } Monitored start: Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed (see Technical details [ 30]).
Relays for functional safety Safety relays PNOZ X PNOZ X2P Wiring Please note: } Information given in the "Technical details [ } The outputs 13-14, 23-24 are safety contacts. } Do not connect undesignated terminals. } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 30]). } Calculation of the max. cable length lmax in the input circuit: Imax = 30]" must be followed. Rlmax Rl / km Rlmax = max.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Preparing for operation Supply voltage AC UB = 24 VAC/DC UB = 48-240 VAC/DC DC A1 L1 A1 L+ A2 N A2 L- A1 L1 A1 L+ A2 N A2 L- FE Input circuit FE Single-channel (only UB 24 VAC/ Dual-channel (with detection of DC) shorts across contacts) E-STOP S1 S1 A1 L+ S21 S22 S11 S21 S11 S22 S12 S12 Safety gate S1 A1 S21 S22 S11 S12 Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Single-channel (only UB 24 VAC/ Dual-channel (with detection of DC) shorts across contacts) Start circuit Automatic start Manual start S3 S3 S33 S34 S33 S34 Y36 Y36 Y37 Y37 Monitored start Feedback loop Automatic start Contacts from external contactors Monitored start S33 S34 K5 13 (23) 14 (24) K6 L1 K5 N K6 Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed
Relays for functional safety Safety relays PNOZ X PNOZ X2P Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Inputs Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Relay outputs Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C Conventional thermal current Contact material Times Switch-on delay With automatic start typ. With automatic start max.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Times 777303 777307 180 ms 180 ms 30 ms 30 ms 20 ms ∞ 20 ms ∞ Environmental data 777303 777307 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Mechanical data 777303 777307 Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Dimensions Height Width Depth Weight plug-in plug-in 0,25 - 2,5 mm², 24 - 12 AWG 0,25 - 2,5 mm², 24 - 12 AWG 0,25 - 1
Relays for functional safety Safety relays PNOZ X PNOZ X2P Inputs Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Relay outputs Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C Conventional thermal current Contact material Times Switch-on delay With automatic start typ. With automatic start max.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Times 787303 787307 180 ms 180 ms 30 ms 30 ms 20 ms ∞ 20 ms ∞ Environmental data 787303 787307 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Mechanical data 787303 787307 Mounting type Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight plug-in plug-in 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 2 2 8 mm 8 mm 101 mm 22,5 mm 121 mm 200 g 101 mm 22,5 mm 121 mm 200 g Where standards are und
Relays for functional safety Safety relays PNOZ X PNOZ X2P Service life graph The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Unit types with UB 24 VAC/DC UB: 24 VAC/DC; Order no. 777303, 787303 Number of cycles x 1000 } Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ X2P Unit types with UB 48-240 VAC/DC UB: 48-240 VAC/DC; Order no. 777307, 787307 Switching current (A) } Cycles x 1000 Example } Inductive load: 2 A } Utilisation category AC15 } Contact service life: 400 000 cycles Provided the application to be implemented requires fewer than 400 000 cycles, the PFH value (see Technical details) can be used in the calculation.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Block diagram/terminal configuration Y11 Y12 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X2.1VP provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the start circuit S33-S34 is closed.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Operating modes } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected. } Dual-channel operation with detection of shorts across contacts: Redundant input circuit, PNOZ X2.1VP detects – earth faults in the start and input circuit, – short circuits in the input circuit, – shorts across contacts in the input circuit.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Feedback loop Automatic start Contacts from external contactors Manual start S33 S34 27 (37) 28 (38) K5 S33 K6 L1 K5 K6 N S34 27 (37) 28 (38) S3 K5 K6 K5 L1 N K6 Semiconductor output Low level at the input of the driven unit Fault: High level of the driven unit After opening the input circuit Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Application example PNOZ X2.1VP L+ L- Fig.: Variable frequency inverter with semiconductor output Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Technical details General 777600 787600 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 777600 787600 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 1,5 W 20 % 100 % 1,5 W 20 % 100 % 1,7 A 1,5 ms 1,7 A 1,5 ms Inputs 777600 787600 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Environmental data 777600 787600 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, delayed <30 PL d s Cat. 3 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,64E-09 SIL 3 1,26E-05 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PNOZ X2.1VP Service life graph Switching current (A) The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P PNOZ X2.3P Unit features } Positive-guided relay outputs: – } } 3 safety contacts (N/O), instantaneous Connection options for: – E-STOP pushbutton – Safety gate limit switch – Start button LED display for: – Supply voltage – Switch status of the safety contacts } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P Block diagram/terminal configuration *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X2.3P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the start circuit S33-S34 is closed.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P } Manual start: Unit is active once the input circuit and the start circuit are closed. } Monitored start: Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed (see Technical details [ 60]). } Increase in the number of available contacts by connecting contact expander modules or external contactors/relays.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P Wiring Please note: } Information given in the "Technical details [ } The output contacts 13-14, 23-24, 33-34 are safety contacts. } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 60]). } Calculation of the max. cable length lmax in the input circuit: Imax = 60]" must be followed. Rlmax Rl / km Rlmax = max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P Feedback loop Automatic start Monitored start Contacts from external contactors Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P Relay outputs 777304 787304 Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Times Switch-on delay With automatic start typ. With automatic start max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P Times 777304 787304 Simultaneity, channel 1 and 2 max. ∞ ∞ Environmental data 777304 787304 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.3P Service life graph Switching current (A) The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Block diagram/terminal configuration Type: 24 VAC/DC } UB: 24 VAC/DC; Order no. 777305, 787305 S11 S52 S21 S22 S12 S34 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Type: 24 - 240 V AC/DC } UB: 24 – 240 VAC/DC; Order no. 777306, 787306 S11 S52 S21 S22 S12 S34 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X2.7P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Operating modes } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected. } Dual-channel operation without detection of shorts across contacts: Redundant input circuit, detects PNOZ X2.7P } – earth faults in the start and input circuit, – short circuits in the input circuit. Dual-channel operation with detection of shorts across contacts: Redundant input circuit, PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P 4. Reset the fuse: remove the short circuit and switch off the supply voltage for approx. 1 minute. Preparing for operation Supply voltage AC DC UB = 24 VAC/DC; Order no. 777305, 787305 UB = 24 - 240 VAC/DC; Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Input circuit Single-channel Dual-channel Single-channel Dual-channel Light guards or safety switch, detection of shorts across contacts via ESPE (only when UB = 24 VDC); Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Inputs Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Times 777305 777306 50 ms 200 ms 50 ms 1500 ms 250 ms 300 ms 30 ms 30 ms 20 ms ∞ 20 ms ∞ Environmental data 777305 777306 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -35 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Electrical data 787305 787306 Max. inrush current impulse Current pulse, A1 Pulse duration, A1 1,7 A 3,3 ms – – Inputs 787305 787306 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Relay outputs 787305 787306 EN 60947-5-1 260 A²s 10 A 6A 6A EN 60947-5-1 66 A²s 6A 4A 6A 6A 4A 160 A²s 10 A 6A 6A 66 A²s 6A 4A 6A 6A AgCuNi + 0,2 µm Au 4A AgCuNi + 0,2 µm Au 787305 787306 6A 6A 4A 6A 3,5 A 4,5 A 6A 6A 6A 6A 5A 4,5 A Times 787305 787306 Switch-on delay With monitored start typ. With monitored start max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Environmental data 787305 787306 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Supplementary data The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components.
Relays for functional safety Cycles x 1000 Safety relays PNOZ X PNOZ X2.7P Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 73]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Unit types with UB 24-240 VAC/DC UB: 24 – 240 VAC/DC; Order no. 777306, 787306 Cycles x 1000 } Switching current (A) Number of cycles x 1000 Fig.: Service life graphs at 24 V DC and 230 V AC Switching current (A) Fig.: Service life graphs at 110 V DC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X2.7P Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 73]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts. With capacitive loads, any power surges that occur must be noted.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Block diagram/terminal configuration Type: 24 VAC/DC } UB: 24 VAC/DC; Order no. 777301, 787301 S11 S52 S21 S22 S12 S34 PNOZ X2.8P *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Type: 24 - 240 V AC/DC } UB: 24 – 240 VAC/DC; Order no. 777302, 787302 S11 S52 S21 S22 S12 S34 PNOZ X2.8P *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PPNOZ X2.8P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Operating modes } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected. } Dual-channel operation without detection of shorts across contacts: Redundant input circuit, detects PNOZ X2.8P } – earth faults in the start and input circuit, – short circuits in the input circuit. Dual-channel operation with detection of shorts across contacts: Redundant input circuit, PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P } b: Start circuit closes before input circuit } t1: Switch-on delay } t2: Delay-on de-energisation } t3: Recovery time Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Important for detection of shorts across contacts: As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during the final control check. If there is a danger of exceeding the cable runs, we recommend the following test after the installation of the device: 1. Unit ready for operation (output contacts closed) 2. Short circuit the test terminals S12, S22 for detecting shorts across the inputs. 3.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Inputs Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Times 777301 777302 15 ms 30 ms 60 ms 100 ms – 10 ms 20 ms – – 1100 ms – – – 1500 ms 180 ms 230 ms 50 ms 200 ms 50 ms 1500 ms 20 ms ∞ 20 ms ∞ Environmental data 777301 777302 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -35 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Environmental data 777301 777302 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Inputs Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Times Switch-on delay With automatic start typ. With automatic start max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Environmental data 787301 787302 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -35 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61000-6-4, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Mechanical data 787301 787302 Dimensions Height Width Depth Weight 101 mm 22,5 mm 121 mm 190 g 101 mm 22,5 mm 121 mm 210 g Where standards are undated, the 2014-07 latest editions shall apply. Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Service life graph The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Unit types with UB 24 VAC/DC UB: 24 VAC/DC; Order no. 777301, 787301 Cycles x 1000 } Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co.
Relays for functional safety Cycles x 1000 Safety relays PNOZ X PNOZ X2.8P Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 96]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Unit types with UB 24-240 VAC/DC UB: 24 – 240 VAC/DC; Order no. 777302, 787302 Cycles x 1000 } Switching current (A) Number of cycles x 1000 Fig.: Service life graphs at 24 V DC and 230 V AC Switching current (A) Fig.: Service life graphs at 110 V DC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X2.8P Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 96]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts. With capacitive loads, any power surges that occur must be noted.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Block diagram/terminal configuration *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X2.9P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the start circuit S12-S34 is closed.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P } Automatic start: Unit is active once the input circuit has been closed. } Manual start: Unit is active once the input circuit and the start circuit are closed. } Monitored start: Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed (see Technical details [ 118]).
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Preparing for operation Supply voltage Input circuit E-STOP without detection of shorts across contacts AC DC Single-channel A1 L+ A2 L- Dual-channel S1 S1 S11 S11 S12 S12 S52 S52 Safety gate without detection of shorts across contacts S1 S11 S11 S1 S12 S52 Light guard or safety switch, detection of shorts across contacts via ESPE S2 S12 S52 A2 S12 S52 GND Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Inputs Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max. overall cable resistance Rlmax Single-channel at UB DC Dual-channel without detection of shorts across contacts at UB DC Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Auxiliary contacts (N/C) Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Relay outputs Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Conventional thermal current while loading several contacts 777300 Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact 6A Conv. therm. current with 2 con6A tacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Environmental data 777300 787300 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Mechanical data Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 777300 787300 – 2 – 8 mm 94 mm 22,5 mm 121 mm 180 g 101 mm 22,5 mm 121 mm 180 g Where standards are undated, the 2014-07 latest editions shall apply. Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat.
Relays for functional safety Cycles x 1000 Safety relays PNOZ X PNOZ X2.9P Switching current (A) Number of cycles x 1000 Fig.: Service life graphs at 24 VDC and 230 VAC Switching current (A) Fig.: Service life graphs at 110 VDC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X2.9P Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 118]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts. With capacitive loads, any power surges that occur must be noted.
Relays for functional safety Safety relays PNOZ X PNOZ X3P PNOZ X3P Unit features } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } 1 semiconductor output } Connection options for: } } – E-STOP pushbuttons – Safety gate limit switches – Start button – Light guards and safety switches LED display for: – Supply voltage – Switch status of the safety contacts Semiconductor output signals: – Switch state of the safety
Relays for functional safety Safety relays PNOZ X PNOZ X3P Block diagram/terminal configuration Type: 24 VAC/DC } UB: 24 VAC/DC; Order no. 777310, 787310 S11 S12 S21 S22 S31 S32 S13 S14 S33 S34 13 23 33 41 * 0 V 24 V Y30 Y31 Y32 14 24 34 42 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Type: 24-240 VAC/DC } UB: 24-240 VAC/DC; Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Function Description The safety relay PNOZ X3P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the start circuit S13-S14 is closed. } } Input circuit is closed (e.g. E-STOP pushbutton not operated): – Safety contacts 13-14, 23-24 and 33-34 are closed, auxiliary contact 41-42 is open. The unit is active. – The LEDs "CH.1" and "CH.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Timing diagram [1] [2] POWER Start Input Output safe Output aux.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24, 33-34 are safety contacts; output 41-42 is an auxiliary contact (e.g. for display). } Auxiliary contact 41-42 should not be used for safety circuits! } Do not connect undesignated terminals.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Preparing for operation Supply voltage 24 VAC/DC 24 - 240 V AC/DC FE Input circuit E-STOP without detection of shorts across contacts Single-channel Dual-channel S1 S1 S12 S11 S21 S11 S21 S22 S32 S31 S22 E-STOP with detection of shorts across contacts S12 S32 S1 S22 Safety gate without detection of shorts across contacts S12 S11 S32 S12 S31 S21 S1 S11 S21 S11 S22 S32 S31 S1 S21 S22 S2 S12 S32 Safety gate with detec
Relays for functional safety Safety relays PNOZ X PNOZ X3P E-STOP wiring Safety gate without start-up test Start circuit Automatic start Safety gate with start-up test S33 S34 S13 S14 S33 S34 S13 S14 Monitored start S3 S33 S34 S13 S14 Feedback loop Automatic start Contacts from external contactors Monitored start S13 S14 13 (23, 33) 14 (24, 34) K5 K6 L1 K5 N K6 Semiconductor output Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } :
Relays for functional safety Safety relays PNOZ X PNOZ X3P Dimensions in mm * With spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Inputs 777310 777313 24 V 24 V 24 V 24 V 24 V 24 V 40 mA 70 mA 20 mA 90 Ohm 35 mA 50 mA 20 mA 90 Ohm 150 Ohm 180 Ohm 200 Ohm 200 Ohm 300 Ohm 400 Ohm 360 Ohm 400 Ohm 15 Ohm 30 Ohm 30 Ohm 30 Ohm Semiconductor outputs 777310 777313 Number Voltage Current External supply voltage Voltage tolerance 1 24 V 20 mA 24 V -20 %/+20 % 1 24 V 20 mA 24 V -20 %/+20 % Relay outputs 777310 777313 Number of output contacts Safety contacts (N
Relays for functional safety Safety relays PNOZ X PNOZ X3P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Times 777310 777313 250 ms 500 ms 330 ms 450 ms 280 ms 750 ms 550 ms 35 ms 50 ms 1.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Environmental data 777310 777313 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III / II 2 250 V 4 kV EN 60947-1 III / II 2 250 V 4 kV IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 777310 777313 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors
Relays for functional safety Safety relays PNOZ X PNOZ X3P Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Inputs 787310 787313 150 Ohm 180 Ohm 200 Ohm 200 Ohm 300 Ohm 400 Ohm 360 Ohm 400 Ohm 15 Ohm 30 Ohm 30 Ohm 30 Ohm Semiconductor outputs 787310 787313 Number Voltage Current External supply voltage Voltage tolerance 1 24 V 20 mA 24 V -20 %/+20 % 1 24 V 20 mA 24 V -20 %/+20 % Relay outputs 787310 787313 3 1 1 kA 3 1 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 8A 2000 VA 24 V 0,01 A 8A 200 W 240 V 0,01 A 8A 2000 VA 24 V 0,01
Relays for functional safety Safety relays PNOZ X PNOZ X3P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Times 787310 787313 15 ms 30 ms 50 ms 70 ms – 25 ms 30 ms – – 1500 ms – – – 2200 ms 150 ms 180 ms 50 ms 100 ms 50 ms 200 ms – 2250 ms 300 ms 200 ms 30 ms 30 ms 20 ms ∞ 20 ms ∞ Environmental data 787310 787313 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -20 - 55 °C -20 - 55 °C -40 -
Relays for functional safety Safety relays PNOZ X PNOZ X3P Environmental data 787310 787313 Rated insulation voltage Rated impulse withstand voltage Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Supplementary data The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components.
Relays for functional safety Safety relays PNOZ X PNOZ X3P Order reference Product type Features Connection type Order no. PNOZ X3P 24 VAC/DC Screw terminals 777 310 PNOZ X3P C 24 VAC/DC Spring-loaded terminals 787 310 PNOZ X3P 24 - 240 V AC/DC Screw terminals 777 313 PNOZ X3P C 24 - 240 V AC/DC Spring-loaded terminals 787 313 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P PNOZ X3.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P Block diagram/terminal configuration S11 S12 S21 S22 S31 S32 * 0 V 24 V Y30 Y31 Y32 S13 S14 S15 S16 S33 S34 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X3.10P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P – shorts across contacts in the input circuit. } Automatic start: Unit is active once the input circuit has been closed. } Manual start: Unit is active once the input circuit and the start circuit are closed. } Monitored start: Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed (see Technical details [ 154]).
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P 3. The unit‘s fuse must be triggered and the output contacts must open. Cable lengths in the scale of the maximum length can delay the fuse triggering for up to 2 minutes. 4. Reset the fuse: Remove the short circuit and switch off the supply voltage for approx. 1 minute.
Relays for functional safety Safety relays PNOZ X PNOZ X3.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P Semiconductor output Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X3.
Relays for functional safety Safety relays PNOZ X PNOZ X3.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P Times 777314 787314 15 ms 30 ms 180 ms 260 ms 15 ms 30 ms 180 ms 260 ms 50 ms 350 ms 50 ms 350 ms 300 ms 300 ms 30 ms 30 ms 150 ms ∞ 150 ms ∞ Environmental data 777314 787314 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -20 - 55 °C -20 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X3.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PNOZ X3.10P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ X7P PNOZ X7P Unit features } Positive-guided relay outputs: – } } 2 safety contacts (N/O), instantaneous Connection options for: – E-STOP pushbutton – Safety gate limit switch – Start button LED display for: – Supply voltage – Switch status of the safety contacts } Plug-in connection terminals } See order reference for unit types Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Block diagram/terminal configuration Types: AC } UB: 110 - 120 VAC; Order no. 777053, 787053 } UB: 230 - 240 VAC; Order no. 777056, 787056 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Types: AC/DC } UB: 24 VAC/DC; Order no. 777059, 787059 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X7P provides a safety-oriented interruption of a safety circuit. When the supply voltage is applied via the E-STOP pushbutton, the “POWER” LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Timing diagram [1] [2] Legend } Power: Supply voltage } Start: Start circuit } Input: Input circuit } Output safe: Safety contacts } [1]: Automatic start } [2]: Manual start } a: Input circuit closes before start circuit } b: Start circuit closes before input circuit } t1: Switch-on delay } t2: Delay-on de-energisation } t3: Recovery time Installation } The unit should be installed in a control cabinet with a protection ty
Relays for functional safety Safety relays PNOZ X PNOZ X7P Wiring Please note: } Information given in the "Technical details [ } Calculating the max. cable length Imax in the input circuit on PNOZ X7P 24 VAC/DC: Imax = 168]" must be followed. Rlmax Rl / km Rlmax = max. overall cable resistance (see Technical details [ Rl / km = cable resistance/km } 168]) Calculating the max. cable length Imax in the input circuit on PNOZ X7P AC units: C C Clmax = max.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Preparing for operation Supply voltage AC 24 VAC/DC A1 L1 A2 N FE Input circuit Single-channel E-STOP Dual-channel S1 L+/L1 A1 Safety gate S1 A1 Start circuit Automatic start L+/L1 Manual start S3 Y1 Y2 Feedback loop Automatic start Manual start Contacts from external contactors Y1 Y2 13 (23) 14 (24) S3 K5 K6 K5 L1 N K6 Legend } S1: E-STOP/safety gate switch } S3: Start button } : Gate open Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X7P } : Gate closed Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Inputs 777053 777056 777059 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Max. overall cable resistance Rlmax Single-channel at UB DC Single-channel at UB AC Max.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Relay outputs Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Times 777053 777056 777059 230 ms 230 ms 50 ms 700 ms 700 ms 150 ms 230 ms 230 ms 50 ms 700 ms 140 ms 700 ms 700 ms 140 ms 700 ms 150 ms 35 ms 150 ms 70 ms 100 ms 70 ms 100 ms 70 ms 100 ms 70 ms 100 ms 45 ms 70 ms 45 ms 70 ms 120 ms 120 ms 120 ms 120 ms 50 ms 150 ms 20 ms 20 ms 20 ms Environmental data 777053 777056 777059 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range C
Relays for functional safety Safety relays PNOZ X PNOZ X7P Environmental data 777053 777056 777059 EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V 4 kV 4 kV 4 kV IP54 IP40 IP20 IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 777053 777056 777059 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible Any 10,000,000 cycles Any 10,000,000 cycles Any 10,000,000 c
Relays for functional safety Safety relays PNOZ X PNOZ X7P Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Times 787056 787059 Supply interruption before de-energisation 20 ms 20 ms 20 ms Environmental data 787053 787056 787059 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ X7P Mechanical data Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 787053 787056 787059 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 2 2 2 8 mm 8 mm 8 mm 101 mm 22,5 mm 121 mm 225 g 101 mm 22,5 mm 121 mm 225 g 101 mm 22,5
Relays for functional safety Number of cycles x 1000 Safety relays PNOZ X PNOZ X7P Switching current (A) Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 4 000 000 cycles Provided the application to be implemented requires fewer than 4 000 000 cycles, the PFH value (see Technical details) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZ X PNOZ X8P PNOZ X8P Unit features } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 2 auxiliary contacts (N/C), instantaneous } 2 semiconductor outputs } Connection options for: } } – E-STOP pushbuttons – Safety gate limit switches – Start button – Light guards and safety switches LED indicator for: – Supply voltage – Input state – Switch state of the safety contacts – Start circuit Semiconductor outputs s
Relays for functional safety Safety relays PNOZ X PNOZ X8P Block diagram/terminal configuration Types: DC } UB: 24 VDC; Order no. 777760, 787760 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Types: AC } UB: 24 VAC; Order no. 777770, 787770 } UB: 110 VAC; Order no. 777764, 787764 } UB: 115 VAC; Order no. 777765 } UB: 120 VAC; Order no. 777766, 787766 } UB: 230 VAC; Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Semiconductor output supply voltage Y35 } A high signal is present at semi-conductor output Y35 if the supply voltage is present and the internal fuse has not blown. Operating modes } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Timing diagram [1] [2] [3] Out semi ON Out semi OUT Legend } Power: Supply voltage } Start: Start circuit } Input: Input circuit } Output safe: Safety contacts } Output aux: Auxiliary contacts } Out semi ON: Semiconductor output supply voltage } Out semi OUT: Semiconductor output switch state } [1]: Automatic start } [2]: Manual start } [3]: Monitored start } a: Input circuit closes before start circuit } b: Start circuit
Relays for functional safety Safety relays PNOZ X PNOZ X8P Wiring Please note: } Information given in the "Technical details [ } Delivery status of units with screw terminals: Link between Y1-Y2 (feedback loop) } Outputs 13-14, 23-24, 33-34 are safety contacts, outputs 41-42, 51-52 are auxiliary contacts (e.g. for display). } Do not use auxiliary contacts 41-42, 51-52 for safety circuits! } Do not connect undesignated terminals.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Preparing for operation Supply voltage AC DC A1 L1 A2 N FE Input circuit E-STOP without detection of shorts across contacts Single-channel A1 L+ A2 L- Dual-channel S1 S1 S11 S11 S21 S12 S21 S22 S52 S22 E-STOP with detection of shorts across contacts S12 S52 S1 S11 Safety gate without detection of shorts across contacts S11 S21 S52 S22 S12 S1 S11 S21 S22 S12 S52 S11 S1 S21 S22 S2 S12 S52 Simultaneity S1 and S2: 15
Relays for functional safety Safety relays PNOZ X PNOZ X8P Start circuit E-STOP/safety gate wiring (single-channel, dual-channel without detection of shorts across contacts) E-STOP/safety gate wiring (dual-channel with detection of shorts across contacts) Automatic start Automatic start with start-up test Manual start S3 S33 S34 Monitored start S3 S33 S34 Y1 S37 Feedback loop S3 S12 S34 Y1 S37 without feedback loop monitoring with feedback loop monitoring Link or contacts from external contact
Relays for functional safety Safety relays PNOZ X PNOZ X8P Semiconductor output Legend } S1: E-STOP pushbuttons } S3: Start button } : Switch operated } : Gate open } : Gate closed Dimensions in mm * With spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Inputs 777760 777764 777765 100 Ohm – – – 100 Ohm 100 Ohm 200 Ohm – – – 200 Ohm 200 Ohm 16 Ohm – – – 28 Ohm 28 Ohm Semiconductor outputs 777760 777764 777765 Number Voltage Current External supply voltage Voltage tolerance 2 24 V 50 mA 24 V -20 %/+20 % 2 24 V 50 mA 24 V -20 %/+20 % 2 24 V 50 mA 24 V -20 %/+20 % Relay outputs 777760 777764 777765 3 2 3 2 3 2 1 kA 1 kA 1 kA EN 60947-4-1 EN 60947-4-1 EN 60947-4
Relays for functional safety Safety relays PNOZ X PNOZ X8P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Times 777760 777764 777765 160 ms 175 ms 175 ms 200 ms 220 ms 220 ms 185 ms 200 ms 200 ms 220 ms 190 ms 250 ms 250 ms 190 ms 250 ms 250 ms 190 ms 250 ms 130 ms 130 ms 130 ms 180 ms 180 ms 180 ms 15 ms 30 ms 100 ms 200 ms 15 ms 30 ms 160 ms 220 ms 15 ms 30 ms 160 ms 220 ms 50 ms 180 ms 50 ms 250 ms 50 ms 250 ms 30 ms 30 ms 30 ms 35 ms 35 ms 35 ms Environmental data 777760 777764 777765 Climatic suitability Ambie
Relays for functional safety Safety relays PNOZ X PNOZ X8P Environmental data 777760 777764 777765 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V 4 kV 4 kV 4 kV IP54 IP40 IP20 IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 777760 777764 777765 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section w
Relays for functional safety Safety relays PNOZ X PNOZ X8P Mechanical data 777760 777764 777765 Dimensions Height Width Depth Weight 94 mm 45 mm 121 mm 315 g 94 mm 45 mm 121 mm 415 g 94 mm 45 mm 121 mm 415 g Where standards are undated, the 2014-07 latest editions shall apply. Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Inputs 777766 777768 777770 100 Ohm 100 Ohm 200 Ohm 200 Ohm 28 Ohm 28 Ohm Semiconductor outputs 777766 777768 777770 Number Voltage Current External supply voltage Voltage tolerance 2 24 V 50 mA 24 V -20 %/+20 % 2 24 V 50 mA 24 V -20 %/+20 % 2 24 V 50 mA 24 V -20 %/+20 % Relay outputs 777766 777768 777770 3 2 3 2 3 2 1 kA 1 kA 1 kA EN 60947-4-1 EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 8A 2000 VA 24 V 0,01 A 8A 200 W 240
Relays for functional safety Safety relays PNOZ X PNOZ X8P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Relay outputs External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Times 777766 777768 777770 50 ms 250 ms 50 ms 250 ms 50 ms 250 ms 30 ms 30 ms 30 ms 35 ms 35 ms 35 ms Environmental data 777766 777768 777770 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C -40 - 85 °C 93 % r.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Mechanical data Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Dimensions Height Width Depth Weight 777766 777768 777770 PPO UL 94 V0 ABS UL 94 V0 PPO UL 94
Relays for functional safety Safety relays PNOZ X PNOZ X8P Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Inputs 787760 787764 787766 100 Ohm – – – 100 Ohm 100 Ohm 200 Ohm – – – 200 Ohm 200 Ohm 16 Ohm – – – 28 Ohm 28 Ohm Semiconductor outputs 787760 787764 787766 Number Voltage Current External supply voltage Voltage tolerance 2 24 V 50 mA 24 V -20 %/+20 % 2 24 V 50 mA 24 V -20 %/+20 % 2 24 V 50 mA 24 V -20 %/+20 % Relay outputs 787760 787764 787766 3 2 3 2 3 2 1 kA 1 kA 1 kA EN 60947-4-1 EN 60947-4-1 EN 60947-4
Relays for functional safety Safety relays PNOZ X PNOZ X8P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Times 787760 787764 787766 160 ms 175 ms 175 ms 200 ms 220 ms 220 ms 185 ms 200 ms 200 ms 220 ms 190 ms 250 ms 250 ms 190 ms 250 ms 250 ms 190 ms 250 ms 130 ms 130 ms 130 ms 180 ms 180 ms 180 ms 15 ms 30 ms 100 ms 200 ms 15 ms 30 ms 160 ms 220 ms 15 ms 30 ms 160 ms 220 ms 50 ms 180 ms 50 ms 250 ms 50 ms 250 ms 30 ms 30 ms 30 ms 35 ms 35 ms 35 ms Environmental data 787760 787764 787766 Climatic suitability Ambie
Relays for functional safety Safety relays PNOZ X PNOZ X8P Environmental data 787760 787764 787766 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V 4 kV 4 kV 4 kV IP54 IP40 IP20 IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 787760 787764 787766 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section w
Relays for functional safety Safety relays PNOZ X PNOZ X8P Technical details Order no. 787768-787770 General 787768 787770 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 787768 787770 230 V AC -15 %/+10 % 24 V AC -15 %/+10 % 6,5 VA 50 - 60 Hz 100 % 6,5 VA 50 - 60 Hz 100 % Inputs 787768 787770 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Auxiliary contacts (N/C) Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Relay outputs Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Times 787768 787770 175 ms 220 ms 175 ms 220 ms 200 ms 200 ms 250 ms 190 ms 250 ms 130 ms 180 ms 250 ms 190 ms 250 ms 130 ms 180 ms 15 ms 30 ms 160 ms 220 ms 15 ms 30 ms 160 ms 220 ms 50 ms 250 ms 50 ms 250 ms 30 ms 30 ms 35 ms 35 ms Environmental data 787768 787770 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN
Relays for functional safety Safety relays PNOZ X PNOZ X8P Environmental data 787768 787770 EN 60947-1 III / II 2 250 V 4 kV EN 60947-1 III / II 2 250 V 4 kV IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 787768 787770 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals
Relays for functional safety Safety relays PNOZ X PNOZ X8P Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PNOZ X8P Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 4 000 000 cycles Provided the application to be implemented requires fewer than 4 000 000 cycles, the PFH value (see Technical details) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts. With capacitive loads, any power surges that occur must be noted.
Relays for functional safety Safety relays PNOZ X PNOZ X9P PNOZ X9P Unit features } Positive-guided relay outputs: – 7 safety contacts (N/O), instantaneous – 2 auxiliary contacts (N/C), instantaneous } 2 semiconductor outputs } Connection options for: } } – E-STOP pushbuttons – Safety gate limit switches – Start buttons – Light grids and safety switches with detection of shorts across contacts LED indicator for: – Supply voltage – Input state – Switch state of the safety contacts
Relays for functional safety Safety relays PNOZ X PNOZ X9P Block diagram/terminal configuration Types: DC } UB: 12 VDC; Order no. 777607 } UB: 24 VDC; Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Function Description The safety relay PNOZ X9P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the feedback loop Y1-Y2 and the start circuit S33-S34 are closed. The "START" LED is lit. } } } Input circuit is closed (e.g. E-STOP pushbutton not operated): – The LEDs "CH.1 IN" and "CH.2 IN" are lit.
Relays for functional safety Safety relays PNOZ X PNOZ X9P } Increase in the number of available contacts by connecting contact expander modules or external contactors/relays.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ X9P Important for detection of shorts across contacts: As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during the final control check. If there is a danger of exceeding the cable runs, we recommend the following test after the installation of the device: 1. Unit ready for operation (output contacts closed) 2. Short circuit the test terminals S12, S22 for detecting shorts across the inputs. 3.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Input circuit Single-channel E-STOP Dual-channel S1 S1 S11 without detection of shorts across contacts S11 S21 S12 S21 S22 S52 S22 S12 S52 E-STOP S1 S11 with detection of shorts across contacts S11 S21 S52 S22 S12 Safety gate without detection of shorts across contacts S1 S11 S11 S21 S12 S21 S22 S52 S22 S1 S2 S12 S52 Safety gate with detection of shorts across contacts Light guard or safety switch, detection of sh
Relays for functional safety Safety relays PNOZ X PNOZ X9P Start circuit Single-channel, dual-channel without detection of shorts across contacts Dual-channel with detection of shorts across contacts Automatic start Y1 S37 Y1 S37 Automatic start with start-up test (safety gate, dual-channel) Y1 S37 S33 S34 Simultaneity S1 and S2: 150 ms, UB: 12 V DC: 50 ms Manual start Y1 S37 Y1 S37 Monitored start S3 S33 S34 Feedback loop S3 S12 S34 Y1 Y1 S37 S37 without feedback loop monitoring with fee
Relays for functional safety Safety relays PNOZ X PNOZ X9P Semiconductor output UB: 12 V DC UB: 24 V DC; 24-240 V AC/DC Y31, Y30: External supply voltage Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Inputs 777606 787606 45 Ohm 45 Ohm 45 Ohm 45 Ohm 90 Ohm 90 Ohm 90 Ohm 90 Ohm 15 Ohm 15 Ohm 15 Ohm 15 Ohm Semiconductor outputs 777606 787606 Number Voltage Current External supply voltage Voltage tolerance 2 24 V 20 mA 24 V -20 %/+20 % 2 24 V 20 mA 24 V -20 %/+20 % Relay outputs 777606 787606 7 2 1 kA 7 2 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 8A 2000 VA 24 V 0,01 A 8A 200 W 240 V 0,01 A 8A 2000 VA 24 V 0,01 A 8A 200
Relays for functional safety Safety relays PNOZ X PNOZ X9P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Times 777606 787606 200 ms 250 ms 200 ms 250 ms 500 ms 500 ms 650 ms 200 ms 250 ms 150 ms 220 ms 650 ms 200 ms 250 ms 150 ms 220 ms 20 ms 30 ms 170 ms 250 ms 20 ms 30 ms 170 ms 250 ms 430 ms 430 ms 550 ms 550 ms 230 ms 230 ms 300 ms 300 ms 50 ms 600 ms 300 ms 50 ms 600 ms 300 ms 50 ms 50 ms 20 ms 20 ms Environmental data 777606 787606 Climatic suitability Ambient temperature Temperature range Storage temperature Temperat
Relays for functional safety Safety relays PNOZ X PNOZ X9P Environmental data 777606 787606 EMC EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III / II 2 250 V 4 kV EN 60947-1 III / II 2 250 V 4 kV IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 777606 787606 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with screw ter
Relays for functional safety Safety relays PNOZ X PNOZ X9P Mechanical data Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 777606 787606 – 8 mm 94 mm 90 mm 121 mm 600 g 101 mm 90 mm 121 mm 600 g Where standards are undated, the 2014-07 latest editions shall apply. Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Inputs 777607 777609 787609 45 Ohm 45 Ohm 90 Ohm 90 Ohm 15 Ohm 15 Ohm Semiconductor outputs 777607 777609 787609 Number Voltage Current External supply voltage Voltage tolerance 2 12 V 20 mA 12 V -20 %/+20 % 2 24 V 20 mA 24 V -20 %/+20 % 2 24 V 20 mA 24 V -20 %/+20 % Relay outputs 777607 777609 787609 7 2 7 2 7 2 1 kA 1 kA 1 kA EN 60947-4-1 EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 8A 2000 VA 24 V 0,01 A 8A 200 W 240 V 0
Relays for functional safety Safety relays PNOZ X PNOZ X9P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Times 777607 777609 787609 20 ms 30 ms 60 ms 80 ms 20 ms 30 ms 170 ms 250 ms 20 ms 30 ms 170 ms 250 ms 50 ms 100 ms 50 ms 300 ms 50 ms 300 ms 30 ms 50 ms 50 ms 20 ms 20 ms 20 ms Environmental data 777607 777609 787609 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 EN 60068-2-78 -10 - 5
Relays for functional safety Safety relays PNOZ X PNOZ X9P Mechanical data 777607 777609 787609 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible Any 10,000,000 cycles Any 10,000,000 cycles Any 10,000,000 cycles PPO UL 94 V0 ABS UL 94 V0 PPO UL 94 V0 Screw terminal plug-in PPO UL 94 V0 ABS UL 94 V0 PPO UL 94 V0 Screw terminal plug-in PPO UL 94 V0 ABS UL 94 V0 PPO UL 94 V0 Spring-loaded terminal pl
Relays for functional safety Safety relays PNOZ X PNOZ X9P Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ X9P Order reference Product type Features Connection type Order no. PNOZ X9P 24-240 V AC/DC, 24 V DC Screw terminals 777 606 PNOZ X9P C 24-240 V AC/DC, 24 V DC Spring-loaded terminals 787 606 PNOZ X9P 12 V DC Screw terminals 777 607 PNOZ X9P 24 VDC Screw terminals 777 609 PNOZ X9P C 24 VDC Spring-loaded terminals 787 609 Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P PNOZ X10.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P Block diagram/terminal configuration A1 A2 S11 S12 S21 S22 Y3 Y1 Y2 S33 S34 S37 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X10.11P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P } Dual-channel operation without detection of shorts across contacts: Redundant input circuit, detects PNOZ X10.11P – earth faults in the start and input circuit, – short circuits in the input circuit. } Automatic start: Unit is active once the input circuit has been closed. } Manual start: Unit is active once the input circuit and the start circuit are closed.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P } t1: Switch-on delay } t2: Delay-on de-energisation } t3: Recovery time Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P Important for detection of shorts across contacts: As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during the final control check. If there is a danger of exceeding the cable runs, we recommend the following test after the installation of the device: 1. Unit ready for operation (output contacts closed) 2. Short circuit the test terminals S12, S22 for detecting shorts across the inputs. 3.
Relays for functional safety Safety relays PNOZ X PNOZ X10.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P Without feedback loop monitoring Feedback loop With feedback loop monitoring Link or contacts from external contactors Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P Technical details General 777750 787750 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 777750 787750 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 5,5 W 160 % 100 % 5,5 W 160 % 100 % Inputs 777750 787750 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ X10.
Relays for functional safety Safety relays PNOZ X PNOZ X10.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P Where standards are undated, the 2014-07 latest editions shall apply. Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PNOZ X10.11P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ X11P PNOZ X11P Unit features } Positive-guided relay outputs: – 7 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } 2 semiconductor outputs } Connection options for: } } – E-STOP pushbutton – Safety gate limit switch – Start button LED indicator for: – Supply voltage – Input state – Switch state of the safety contacts – Start circuit Semiconductor outputs signal: – Supply voltage is present –
Relays for functional safety Safety relays PNOZ X PNOZ X11P Block diagram/terminal configuration A1 A2 B1 B2 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X11P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Operating modes } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected. } Dual-channel operation with detection of shorts across contacts: Redundant input circuit, PNOZ X11P detects – earth faults in the start and input circuit, – short circuits in the input circuit, – shorts across contacts in the input circuit.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Timing diagram [1] [2] [3] Out semi ON Out semi OUT Legend } Power: Supply voltage } Start: Start circuit } Input: Input circuit } Output safe: Safety contacts } Output aux: Auxiliary contact } Out semi ON: Semiconductor output supply voltage } Out semi OUT: Semiconductor output switch state } [1]: Automatic start } [2]: Manual start } [3]: Monitored start } a: Input circuit closes before start circuit } b: Start circuit
Relays for functional safety Safety relays PNOZ X PNOZ X11P Wiring Please note: } Information given in the "Technical details [ } Delivery status of units with screw terminals: Link between S11-S12 (dual-channel input circuit) and link between Y1-Y2 (feedback loop) } Outputs 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 are safety contacts; output 81-82 is an auxiliary contact (e.g. for display).
Relays for functional safety Safety relays PNOZ X PNOZ X11P Preparing for operation Supply voltage AC DC FE Input circuit Single-channel E-STOP without detection of shorts across contacts B1 L+ B2 L- Dual-channel S1 S12 S21 S11 S22 S32 S31 E-STOP S1 S22 with detection of shorts across contacts S11 S32 S12 S31 S21 Safety gate without detection of shorts across contacts S12 S21 S11 S22 S32 S31 S1 Safety gate with detection of shorts across contacts Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Start circuit E-STOP wiring (single-channel, dual-channel) Safety gate (single-channel) Safety gate (dual-channel) Automatic start Automatic start with start-up test Simultaneity S1 and S2: 120 ms Manual start S3 S33 S34 Monitored start Feedback loop S3 S33 S34 S3 S3 S33 S34 S33 S34 S37 S37 without feedback loop monitoring with feedback loop monitoring Link or contacts from external contactors Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Semiconductor output Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Inputs 777080 777083 777086 50 Ohm 50 Ohm 50 Ohm 100 Ohm 100 Ohm 100 Ohm 15 Ohm 15 Ohm 15 Ohm 20 Ohm 20 Ohm 20 Ohm Semiconductor outputs 777080 777083 777086 Number Voltage Current External supply voltage Voltage tolerance 2 24 V 20 mA 24 V -20 %/+20 % 2 24 V 20 mA 24 V -20 %/+20 % 2 24 V 20 mA 24 V -20 %/+20 % Relay outputs 777080 777083 777086 7 1 7 1 7 1 1 kA 1 kA 1 kA EN 60947-4-1 EN 60947-4-1 EN 60947-4-1 2
Relays for functional safety Safety relays PNOZ X PNOZ X11P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Times 777080 777083 777086 450 ms 450 ms 450 ms 680 ms 680 ms 680 ms 450 ms 450 ms 450 ms 630 ms 450 ms 680 ms 630 ms 450 ms 680 ms 630 ms 450 ms 680 ms 390 ms 390 ms 390 ms 550 ms 550 ms 550 ms 15 ms 30 ms 40 ms 60 ms 15 ms 30 ms 40 ms 60 ms 15 ms 30 ms 40 ms 60 ms 50 ms 100 ms 50 ms 100 ms 50 ms 100 ms 30 ms 30 ms 30 ms 20 ms 20 ms 20 ms ∞ ∞ ∞ Environmental data 777080 777083 777086 Climatic suitability A
Relays for functional safety Safety relays PNOZ X PNOZ X11P Environmental data 777080 777083 777086 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V 4 kV 4 kV 4 kV IP54 IP40 IP20 IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 777080 777083 777086 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section
Relays for functional safety Safety relays PNOZ X PNOZ X11P Mechanical data 777080 777083 777086 Dimensions Height Width Depth Weight 94 mm 90 mm 121 mm 640 g 94 mm 90 mm 121 mm 640 g 94 mm 90 mm 121 mm 640 g Where standards are undated, the 2014-07 latest editions shall apply. Order no.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Inputs 787080 787083 787086 50 Ohm 50 Ohm 50 Ohm 100 Ohm 100 Ohm 100 Ohm 15 Ohm 15 Ohm 15 Ohm 20 Ohm 20 Ohm 20 Ohm Semiconductor outputs 787080 787083 787086 Number Voltage Current External supply voltage Voltage tolerance 2 24 V 20 mA 24 V -20 %/+20 % 2 24 V 20 mA 24 V -20 %/+20 % 2 24 V 20 mA 24 V -20 %/+20 % Relay outputs 787080 787083 787086 7 1 7 1 7 1 1 kA 1 kA 1 kA EN 60947-4-1 EN 60947-4-1 EN 60947-4-1 2
Relays for functional safety Safety relays PNOZ X PNOZ X11P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Times 787080 787083 787086 450 ms 450 ms 450 ms 680 ms 680 ms 680 ms 450 ms 450 ms 450 ms 630 ms 450 ms 680 ms 630 ms 450 ms 680 ms 630 ms 450 ms 680 ms 390 ms 390 ms 390 ms 550 ms 550 ms 550 ms 15 ms 30 ms 40 ms 60 ms 15 ms 30 ms 40 ms 60 ms 15 ms 30 ms 40 ms 60 ms 50 ms 100 ms 50 ms 100 ms 50 ms 100 ms 30 ms 30 ms 30 ms 20 ms 20 ms 20 ms ∞ ∞ ∞ Environmental data 787080 787083 787086 Climatic suitability A
Relays for functional safety Safety relays PNOZ X PNOZ X11P Environmental data 787080 787083 787086 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V 4 kV 4 kV 4 kV IP54 IP40 IP20 IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 787080 787083 787086 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section
Relays for functional safety Safety relays PNOZ X PNOZ X11P Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PNOZ X11P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P PNOZ XV1P Unit features } } Positive-guided relay outputs: – 2 safety contacts (N/O), instantaneous – 1 safety contact (N/O), delay-on de-energisation Connection options for: – E-STOP pushbuttons – Safety gate limit switches – Start buttons – Light grids and safety switches with detection of shorts across contacts } Selectable delay time } LED display for: – Supply voltage – Switch status of the safety contacts } Plug-in con
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Block diagram/terminal configuration *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ XV1P provides a safety-oriented interruption of a safety circuit. When the supply voltage is applied via the E-STOP pushbutton, the “PWR” LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Operating modes } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected. } Dual-channel operation without detection of shorts across contacts: Redundant input circuit, detects PNOZ XV1P } – earth faults in the start and input circuit, – short circuits in the input circuit.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P } t2: Delay-on de-energisation } t3: Waiting period with a monitored start } t4: Recovery time } tv: Delay time Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ XV1P 3. The unit‘s fuse must be triggered and the output contacts must open. Cable lengths in the scale of the maximum length can delay the fuse triggering for up to 2 minutes. 4. Reset the fuse: Remove the short circuit and switch off the supply voltage for approx. 1 minute.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Input circuit Single-channel Dual-channel Light guard or safety switch, detection of shorts across contacts via ESPE S21 S22 A2 GND E-STOP wiring, safety gate without start-up test Start circuit Automatic start Safety gate with start-up test S11 S14 S1 S2 S11 S14 Simultaneity S1 and S2: max.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Inputs Current at Input circuit DC Start circuit DC Feedback loop DC Max. overall cable resistance Rlmax Single-channel at UB DC Dual-channel without detection of shorts across contacts at UB DC Dual-channel with detection of shorts across contacts at UB DC Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (N/O), delayed Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Relay outputs Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Conventional thermal current while loading several contacts 777601 Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact 5A Conv. therm. current with 2 con3,7 A tacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Environmental data 777601 777602 -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61000-6-3, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Mechanical data 777601 777602 Dimensions Height Width Depth Weight 94 mm 22,5 mm 121 mm 230 g 94 mm 22,5 mm 121 mm 230 g Where standards are undated, the 2014-07 latest editions shall apply. Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Inputs 787601 Max. overall cable resistance Rlmax Single-channel at UB DC 100 Ohm Dual-channel without detection of shorts across contacts at UB DC 150 Ohm Dual-channel with detection of shorts across contacts at UB DC 15 Ohm Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (N/O), delayed Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Relay outputs Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Conventional thermal current while loading several contacts 787601 Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact 5A Conv. therm. current with 2 con3,7 A tacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Environmental data 787601 787602 -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61000-6-3, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Mechanical data 787601 787602 Weight 230 g 230 g Where standards are undated, the 2014-07 latest editions shall apply. Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Safety contacts, delayed <30 s PL d Safety contacts, delayed ≥30 PL c s EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] Cat.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Service life graph The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Cycles x 1000 Service life graph: Safety contacts (N/O), instantaneous Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ XV1P Cycles x 1000 Service life graph: Safety contact (N/O), delay-on de-energisation Switching current (A) Example } Inductive load: 0.2 A, } Utilisation category: AC15 } Contact service life: 900 000 cycles Provided the application to be implemented requires fewer than 900 000 cycles, the PFH value (see Technical details) can be used in the calculation.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P PNOZ XV2P Unit features } } } Positive-guided relay outputs: – 2 safety contacts (N/O), instantaneous – 2 safety contacts (N/O), delay-on de-energisation Connection options for: – E-STOP pushbutton – Safety gate limit switch – Start button LED display for: – Supply voltage – Switch state of the safety contacts – Start circuit } Delay time fixed or selectable } Possible to cancel delay time } Plug-in connection terminals (e
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Block diagram/terminal configuration *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ XV2P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Reset function: The delay time cycle can be ended prematurely by opening the reset circuit Y39-Y40. For this purpose, one N/C contact is connected between Y39-Y40 instead of a link. Operating modes } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P } [2]: Monitored start } t1: Switch-on delay } t2: Delay-on de-energisation } t3: Waiting period with a monitored start } t4: Recovery time } tv: Delay time Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Important for detection of shorts across contacts: As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during the final control check. If there is a danger of exceeding the cable length, we recommend the following test once the unit is installed: 1. Unit ready for operation (output contacts closed) 2. Short circuit the test terminals S22, S32 for detecting shorts across the inputs. 3.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Input circuit Single-channel Dual-channel E-STOP wiring Safety gate without start-up test Safety gate with start-up test Safety gate with detection of shorts across contacts Start circuit Automatic start S33 S34 S13 S14 S33 S34 S13 S14 Simultaneity S1 and S2: max. 3 s Monitored start S3 S33 S34 S13 S14 Reset delay time Without reset Link or N/C contact With reset Y39 Y40 Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Feedback loop Automatic start Contacts from external contactors S13 S14 13 (23) 14 (24) Monitored start K5 K6 L1 K5 N K6 Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (N/O), delayed Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Relay outputs Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max. With monitored start typ.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Times 777500 Supply interruption before de-energisation 20 ms Simultaneity, channel 1 and 2 max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Mechanical data 777500 777502 777503 Mounting type Conductor cross section with screw terminals 1 core flexible plug-in plug-in plug-in 0,25 - 2,5 mm², 24 - 12 AWG 0,25 - 2,5 mm², 24 - 12 AWG 0,25 - 2,5 mm², 24 - 12 AWG 0,25 - 1 mm², 24 - 16 AWG 0,25 - 1 mm², 24 - 16 AWG 0,25 - 1 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 0,5 Nm 0,5 Nm 0,5 Nm 94 mm 45 mm 121 mm 360 g 94 mm
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Inputs 777504 787500 787502 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Relay outputs Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Relay outputs External contact fuse protection, delayed safety contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Times 777504 787500 787502 50 ms +tv 250 ms 0,5 s -15 %/+15 % +50 ms 2% 50 ms +tv 250 ms 0,1 s, 0,5 s, 1 s, 2 s, 4 s, 6 s, 8 s, 10 s, 15 s, 20 s, 25 s, 30 s -15 %/+15 % +50 ms 2% 50 ms +tv 250 ms 0,1 s, 0,2 s, 0,3 s, 0,4 s, 0,5 s, 0,6 s, 0,7 s, 0,8 s, 1 s, 1,5 s, 2 s, 3 s -15 %/+15 % +50 ms 2% 300 ms 300 ms 300 ms 30 ms 30 ms 30 ms 20 ms 20 ms 20 ms ∞ ∞ ∞ Environmental data 777504 787500 787502 Climatic suitability Ambient
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Environmental data 777504 787500 787502 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Order no. 787503 – 787504 General 787503 787504 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 787503 787504 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 4,5 W 160 % 100 % 4,5 W 160 % 100 % 5A 1 ms 5A 1 ms Inputs 787503 787504 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, delayed safety contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Times 787503 787504 15 ms 30 ms 85 ms 200 ms 15 ms 30 ms 85 ms 200 ms 50 ms +tv 250 ms 1s -15 %/+15 % +50 ms 2% 50 ms +tv 250 ms 0,5 s -15 %/+15 % +50 ms 2% 300 ms 300 ms 30 ms 30 ms 20 ms ∞ 20 ms ∞ Environmental data 787503 787504 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Environmental data 787503 787504 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Safety characteristic data Operating mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Safety contacts, delayed <30 s PL d Safety contacts, delayed ≥30 s PL c EN 62061 EN 62061 SIL CL PFHD [1/h] EN ISO 13849-1: 2015 TM [year] Cat. 4 SIL CL 3 2,31E-09 20 Cat. 3 SIL CL 3 2,64E-09 20 Cat.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ XV2P Order reference Product type Features Connection type Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P PNOZ XV2.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Block diagram/terminal configuration *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ XV2.1P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Set delay time: On units with selectable delay time, the delay time of the safety contacts 37-38 and 47-48 can be set on the front of the unit using a screwdriver. Reset function: The delay time cycle can be ended prematurely by opening the reset circuit Y39-Y40. For this purpose, one N/C contact is connected between Y39-Y40 instead of a link.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Wiring Please note: } Information given in the "Technical details [ } Delivery status of units with screw terminals: Link between S11-S12 (dual-channel input circuit) and link between Y39-Y40 (reset circuit) } Outputs 13-14, 23-24 are instantaneous safety contacts, outputs 37-38, 47-48 are delay-on de-energisation safety contacts. } Do not connect undesignated terminals.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Inputs Current at Input circuit DC Start circuit DC Feedback loop DC Max. overall cable resistance Rlmax Single-channel at UB DC Single-channel at UB AC Dual-channel with detection of shorts across contacts at UB DC Dual-channel with detection of shorts across contacts at UB AC Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (N/O), delayed Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Relay outputs Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Relay outputs External contact fuse protection, delayed safety contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Times 777540 777542 777544 400 ms 400 ms 400 ms 550 ms 550 ms 550 ms 820 ms 820 ms 820 ms 1.100 ms 1.100 ms 1.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Environmental data 777540 777542 777544 -10 - 55 °C -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Inputs Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Relay outputs Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Relay outputs External contact fuse protection, delayed safety contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Where standards are undated, the 2014-07 latest editions shall apply. Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (N/O), delayed Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Relay outputs Utilisation category in accordance with UL Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, delayed safety contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max. With monitored start typ.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Times 787542 787548 Supply interruption before de-energisation 20 ms Simultaneity, channel 1 and 2 max. ∞ 20 ms ∞ Environmental data 787542 787548 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Mechanical data Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 787542 787548 2 2 8 mm 8 mm 101 mm 90 mm 121 mm 515 g 101 mm 90 mm 121 mm 515 g Where standards are undated, the 2014-07 latest editions shall apply.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ XV2.1P Order reference Product type Features Connection type Order no. PNOZ XV2.1P C 24-240 VAC/DC; Delay: up to 3 s selectable Spring-loaded terminals 787 542 PNOZ XV2.1P Screw terminals 777 542 PNOZ XV2.1P C 24-240 VAC/DC; Delay: up to 30 s selectable Spring-loaded terminals 787 540 PNOZ XV2.1P Screw terminals 777 540 PNOZ XV2.1P C 24-240 VAC/DC; Delay: up to 300 s selectable Spring-loaded terminals 787 548 PNOZ XV2.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P PNOZ XV3P Unit features } } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 2 safety contacts (N/O), delay-on de-energisation Connection options for: – E-STOP pushbuttons – Safety gate limit switches – Start buttons – Light grids and safety switches with detection of shorts across contacts } Delay time fixed or selectable } Possible to cancel delay time } LED display for: – Supply voltage – Switch s
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Block diagram/terminal configuration * *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ XV3P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Set delay time: On units with selectable delay time, the delay time of the safety contacts 47-48 and 57-58 can be set on the front of the unit using a screwdriver. Reset function: The delay time cycle can be ended prematurely by opening the reset circuit Y39-Y40. For this purpose, one N/C contact is connected between Y39-Y40 instead of a link.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Timing diagram [1] [2] Output safe Output safe delay v v v v Legend } Power: Supply voltage } Start: Start circuit } Reset tv: Reset circuit } Input: Input circuit } Output safe: Safety contacts, instantaneous } Output safe delay: Safety contacts, delayed } [1]: Automatic start } [2]: Monitored start } t1: Switch-on delay } t2: Delay-on de-energisation } t3: Waiting period with a monitored start } t4: Recovery time }
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Wiring Please note: } Information given in the "Technical details [ } Delivery status of units with screw terminals: Link between S11-S12 (dual-channel input circuit) and link between Y39-Y40 (reset circuit) } Outputs 13-14, 23-24, 33-34 are instantaneous safety contacts, outputs 47-48, 57-58 are delay-on de-energisation safety contacts. } Do not connect undesignated terminals.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Preparing for operation Supply voltage Input circuit AC DC Single-channel E-STOP without detection of shorts across contacts A1 L+ A2 L- Dual-channel S1 S1 S12 S11 S21 S11 S21 S22 S32 S31 S22 S12 S32 E-STOP S1 S22 with detection of shorts across contacts S11 S32 S12 S31 S21 Safety gate without detection of shorts across contacts S12 S21 S22 S1 S11 S11 S32 S31 S1 S21 S22 S2 S12 S32 Safety gate with detection of
Relays for functional safety Safety relays PNOZ X PNOZ XV3P E-STOP wiring Safety gate without start-up test Start circuit Automatic start Safety gate with start-up test S33 S34 S13 S14 S33 S34 S13 S14 Simultaneity S1 and S2: max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Inputs Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Relay outputs Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Relay outputs External contact fuse protection, delayed safety contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Times 777510 777512 777514 15 ms 30 ms 85 ms 200 ms 15 ms 30 ms 85 ms 200 ms 15 ms 30 ms 85 ms 200 ms 50 ms +tv 250 ms 0,1 s, 0,5 s, 1 s, 2 s, 4 s, 6 s, 8 s, 10 s, 15 s, 20 s, 25 s, 30 s -15 %/+15 % +50 ms 2% 50 ms +tv 250 ms 0,1 s, 0,2 s, 0,3 s, 0,4 s, 0,5 s, 0,6 s, 0,7 s, 0,8 s, 1 s, 1,5 s, 2 s, 3 s -15 %/+15 % +50 ms 2% 50 ms +tv 250 ms 300 ms 300 ms 300 ms 30 ms 30 ms 30 ms 20 ms 20 ms 20 ms ∞ ∞ ∞ Environmental data 7775
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Environmental data 777510 777512 777514 EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V 4 kV 4 kV 4 kV IP54 IP40 IP20 IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 777510 777512 777514 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible Any 10,000,000 cycles Any 10,000,000 cycles Any 10,000,000
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (N/O), delayed Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Relay outputs Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Conv. therm. current with 5 contacts Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Times 777515 Min. start pulse duration with a monitored start 30 ms Supply interruption before de-energisation 20 ms Simultaneity, channel 1 ∞ and 2 max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Mechanical data Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Dimensions Height Width Depth Weight 777515 777517 777518 PPO UL 94 V0 ABS UL 94 V0 PPO UL 9
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Electrical data 787510 787512 787518 Duty cycle Max. inrush current impulse Current pulse, A1 Pulse duration, A1 100 % 100 % 100 % 5A 1 ms 5A 1 ms 5A 1 ms Inputs 787510 787512 787518 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Min. input resistance at power-on Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, delayed safety contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Times 787510 787512 787518 350 ms 350 ms 350 ms 650 ms 650 ms 650 ms 385 ms 385 ms 385 ms 700 ms 700 ms 700 ms 35 ms 35 ms 35 ms 70 ms 70 ms 70 ms 15 ms 30 ms 85 ms 200 ms 15 ms 30 ms 85 ms 200 ms 15 ms 30 ms 85 ms 200 ms 50 ms +tv 250 ms 0,1 s, 0,5 s, 1 s, 2 s, 4 s, 6 s, 8 s, 10 s, 15 s, 20 s, 25 s, 30 s -15 %/+15 % +50 ms 2% 50 ms +tv 250 ms 0,1 s, 0,2 s, 0,3 s, 0,4 s, 0,5 s, 0,6 s, 0,7 s, 0,8 s, 1 s, 1,5 s, 2 s, 3 s -1
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Environmental data Condensation during operation EMC Vibration In accordance with the standard Frequency Amplitude Airgap creepage In accordance with the standard Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Mechanical data 787510 787512 787518 Dimensions Height Width Depth Weight 101 mm 45 mm 121 mm 370 g 101 mm 45 mm 121 mm 370 g 101 mm 45 mm 121 mm 370 g Where standards are undated, the 2014-07 latest editions shall apply.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ XV3P Order reference Product type Features Connection type Order no. PNOZ XV3P 24 VDC; Delay: 0.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P PNOZ XV3.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Block diagram/terminal configuration Types: AC/DC } UB: 24 - 240 VAC/DC; Order no. 777530, 787530, 777532, 787532, 777538, 787538 *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Types: DC } UB: 24 VDC; Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Function Description The safety relay PNOZ XV3.1P provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the reset circuit Y39-Y40 and the start circuit S13-S14 are closed. } } Input circuit is closed (e.g. E-STOP pushbutton not operated): – The "START" LED is lit. – The LEDs "CH.1", "CH.1 [t]", "CH.2" and "CH.2 [t]" are lit.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P } Automatic start: Unit is active once the input circuit has been closed. } Monitored start: Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed (see Technical details [ 380]). } Increase in the number of available contacts by connecting contact expander modules or external contactors/relays.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Important for detection of shorts across contacts: As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during the final control check. If there is a danger of exceeding the cable length, we recommend the following test once the unit is installed: 1. Unit ready for operation (output contacts closed) 2. Short circuit the test terminals S22, S32 for detecting shorts across the inputs. 3.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Feedback loop Automatic start Contacts from external contactors Monitored start S13 S14 13 (23, 33) 14 (24, 34) K5 K6 L1 K5 N K6 Legend } S1/S2: E-STOP/safety gate switch } S3: Reset button } : Switch operated } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (N/O), delayed Auxiliary contacts (N/C) Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs External contact fuse protection, delayed safety contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Environmental data Condensation during operation EMC Vibration In accordance with the standard Frequency Amplitude Airgap creepage In accordance with the standard Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Mechanical data Torque setting with screw terminals Dimensions Height Width Depth Weight 777520 777522 777525 0,5 Nm 0,5 Nm 0,5 Nm 94 mm 90 mm 121 mm 510 g 94 mm 90 mm 121 mm 510 g 94 mm 90 mm 121 mm 500 g Where standards are undated, the 2014-07 latest editions shall apply. Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Inputs Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, delayed safety contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Conv. therm. current with 5 contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Mechanical data 777530 777532 777538 Dimensions Height Width Depth Weight 94 mm 90 mm 121 mm 540 g 94 mm 90 mm 121 mm 540 g 94 mm 90 mm 121 mm 540 g Where standards are undated, the 2014-07 latest editions shall apply. Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Inputs Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, delayed safety contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Conv. therm. current with 5 contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Environmental data 787520 EMC EN 60947-5-1, EN EN 60947-5-1, EN EN 60947-5-1, EN 61000-6-2, EN 61000-6-4, 61000-6-2, EN 61326-3-1 61000-6-2, EN 61326-3-1 EN 61326-3-1 Vibration In accordance with the standard Frequency Amplitude Airgap creepage In accordance with the standard Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Mechanical data 787520 787522 787530 Weight 510 g 510 g 535 g Where standards are undated, the 2014-07 latest editions shall apply. Technical details Order no.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Inputs Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, delayed safety contacts Max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Conv. therm. current with 5 contacts Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Times 787532 Min. start pulse duration with a monitored start 30 ms Supply interruption before de-energisation 20 ms Simultaneity, channel 1 and 2 max.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PNOZ XV3.1P Order reference Product type Features Connection type Order no. PNOZ XV3.1P 24 VDC; Delay: up to 3 s selectable Screw terminals 777 522 PNOZ XV3.1P C 24 VDC; Delay: up to 3 s selectable Spring-loaded terminals 787 522 PNOZ XV3.1P 24 VDC; Delay: 3 s fixed Screw terminals 777 525 PNOZ XV3.1P 24 VDC; Delay: up to 30 s selectable Screw terminals 777 520 PNOZ XV3.
Relays for functional safety Safety relays PNOZ X PZE X4P PZE X4P Unit features } Positive-guided relay outputs: – } 4 safety contacts (N/O), instantaneous LED display for: – Switch status of the safety contacts } Connection for feedback loop } Operation: single-channel } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Block diagram/terminal configuration * PZE *Insulation between the non-marked area and the relay contacts
Relays for functional safety Safety relays PNOZ X PZE X4P Function description The contact expansion module PZE X4P is an add-on device without delay-on de-energisation, and it is used to expand a safety circuit. The contact expansion module is driven by a base unit (e. g. emergency stop relay). } } Functional procedure once the input circuit is closed (e.g. safety contacts on the base unit are closed): – The supply voltage is present at input (A1) of the contact expansion module.
Relays for functional safety Safety relays PNOZ X PZE X4P } Do not switch low currents using contacts that have been used previously with high currents. } The power supply must comply with the regulations for extra low voltages with protective electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410. } Ensure the wiring and EMC requirements of IEC 60204-1 are met.
Relays for functional safety Safety relays PNOZ X PZE X4P Dimensions in mm * with spring-loaded terminals Technical details General 777585 787585 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 777585 787585 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 2,5 W 20 % 100 % 2,5 W 20 % 100 % 1,7 A 1 ms 1,7 A 1 ms Inputs 777585 787585 Number Voltage at Input circuit DC Current at Input circuit DC 1 1 24 V 24 V 95 mA 95 mA Supply
Relays for functional safety Safety relays PNOZ X PZE X4P Inputs 777585 787585 Max. overall cable resistance Rlmax Single-channel at UB DC 30 Ohm 30 Ohm Relay outputs 777585 787585 4 1 kA 4 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W EN 60947-5-1 EN 60947-5-1 230 V 5A 24 V 5A 230 V 5A 24 V 5A 240 V AC G.U. (same polarity) 6A 24 V DC G. U. 6A R300 240 V AC G.U. (same polarity) 6A 24 V DC G. U.
Relays for functional safety Safety relays PNOZ X PZE X4P Relay outputs 777585 787585 EN 60947-5-1 260 A²s 10 A 6A 10 A EN 60947-5-1 260 A²s 10 A 6A 10 A 6A AgCuNi + 0,2 µm Au 6A AgCuNi + 0,2 µm Au 777585 787585 6A 6A 6A 6A 5A 5A 4A 4A 777585 787585 30 ms 30 ms 50 ms 50 ms 30 ms 50 ms 30 ms 50 ms 30 ms 50 ms 30 ms 50 ms 20 ms 20 ms Environmental data 777585 787585 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitabil
Relays for functional safety Safety relays PNOZ X PZE X4P Environmental data 777585 787585 Condensation during operation EMC Not permitted EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 Not permitted EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III / II 2 250 V 4 kV EN 60947-1 III / II 2 250 V 4 kV IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 777585 787585 Mounting position Mechanical life Material Bottom Front Top Connection
Relays for functional safety Safety relays PNOZ X PZE X4P Mechanical data Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 777585 787585 – 8 mm 94 mm 22,5 mm 121 mm 170 g 101 mm 22,5 mm 121 mm 170 g Where standards are undated, the 2014-07 latest editions shall apply. Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat.
Relays for functional safety Safety relays PNOZ X PZE X4P Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Cycles x 1000 Safety relays PNOZ X PZE X4P Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 412]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZ X PZE X4.1P PZE X4.1P Unit features } Positive-guided relay outputs: – } 4 safety contacts (N/O), instantaneous LED display for: – Supply voltage – Switch status of the safety contacts } Connection for feedback loop } Suitable to be driven via OSSD } Operation: Single or dual-channel } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Block diagram/terminal configuration Type: DC } UB: 24 DC; Order no. 777587, 787587 PZE X4.1P *Safe separation from non-marked area in accordance with EN 60947-1, 6 kV, basic insulation between all safety contacts. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Type: AC/DC } UB: 24 - 240 VAC/DC; Order no. 777588, 787588 PZE X4.1P *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function description The contact expansion module PZE X4.1P is an add-on device without delay-on de-energisation. It is used to expand a safety circuit. The contact expansion module is driven by a base unit (e. g.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Installation } The unit should be installed in a control cabinet with a protection type of at least IP54. } Use the notch on the rear of the unit to attach it to a DIN rail. } Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).
Relays for functional safety Safety relays PNOZ X PZE X4.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Inputs 777587 Current at Input circuit DC 35 mA Max. overall cable resistance Rlmax Single-channel at UB DC 30 Ohm Dual-channel without detection of shorts across contacts at UB 60 Ohm DC Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min.
Relays for functional safety Safety relays PNOZ X PZE X4.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Environmental data 777587 787587 -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Mechanical data Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 777587 787587 – 0,2 - 1,5 mm², 24 - 16 AWG – 2 – 8 mm 94 mm 22,5 mm 121 mm 185 g 101 mm 22,5 mm 121 mm 185 g Where standards are undated, the 2014-07 latest editions shall apply. Order no.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Inputs Max. overall cable resistance Rlmax Single-channel at UB DC Single-channel at UB AC Dual-channel without detection of shorts across contacts at UB DC Dual-channel without detection of shorts across contacts at UB AC Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Times 777588 787588 10 ms 20 ms 1300 ms 10 ms 20 ms 1300 ms 1900 ms 270 ms 350 ms 1900 ms 270 ms 350 ms 2 ms 2 ms 20 ms 20 ms Environmental data 777588 787588 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PZE X4.
Relays for functional safety Safety relays PNOZ X PZE X4.1P Supplementary data The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components.
Relays for functional safety Number of cycles x 1000 Safety relays PNOZ X PZE X4.1P Switching current (A) Fig.: Service life graphs at 110 VDC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 424]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts.
Relays for functional safety Safety relays PNOZ X PZE X4VP PZE X4VP Unit features } Positive-guided relay outputs: – } 4 safety contacts (N/O), delay-on de-energisation LED display for: – Switch status of the safety contacts } Connection for feedback loop } Operation: single-channel } Unit types with various delay times } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Block diagram/terminal configuration * PZE *Insulati
Relays for functional safety Safety relays PNOZ X PZE X4VP Function description The contact expansion module PZE X4VP is an add-on device with delay-on de-energisation, and it is used to expand a safety circuit. The contact expansion module is driven by a base unit (e. g. emergency stop relay). } } Functional procedure once the input circuit is closed (e.g. safety contacts on the base unit are closed): – The supply voltage is present at input (A1) of the contact expansion module.
Relays for functional safety Safety relays PNOZ X PZE X4VP } Do not switch low currents using contacts that have been used previously with high currents. } The power supply must comply with the regulations for extra low voltages with protective electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410. } Ensure the wiring and EMC requirements of IEC 60204-1 are met.
Relays for functional safety Safety relays PNOZ X PZE X4VP Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PZE X4VP Inputs 777580 777581 777582 95 mA 95 mA 30 Ohm 30 Ohm 777580 777581 777582 4 4 4 1 kA 1 kA 1 kA EN 60947-4-1 EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W EN 60947-5-1 EN 60947-5-1 EN 60947-5-1 230 V 3A 24 V 4A 230 V 3A 24 V 4A 230 V 3A 24 V 4A 250 V AC G.U. (same polarity) 6A 24 V DC G. U.
Relays for functional safety Safety relays PNOZ X PZE X4VP Relay outputs External contact fuse protection, safety contacts In accordance with the standard External contact fuse protection, delayed safety contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv.
Relays for functional safety Safety relays PNOZ X PZE X4VP Environmental data Climatic suitability Humidity Condensation during operation EMC Vibration In accordance with the standard Frequency Amplitude Airgap creepage In accordance with the standard Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Mounting area (e.g. control cabinet) Housing Terminals 777580 777581 777582 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PZE X4VP Mechanical data Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Dimensions Height Width Depth Weight 777580 777581 777582 0,25 - 2,5 mm², 24 - 12 AWG 0,25 - 2,5 mm², 24 - 12 AWG 0,25 - 2,5 mm², 24 - 12 AWG 0,25
Relays for functional safety Safety relays PNOZ X PZE X4VP Inputs 777583 787580 787581 Number Voltage at Input circuit DC Current at Input circuit DC Max.
Relays for functional safety Safety relays PNOZ X PZE X4VP Relay outputs 777583 787580 787581 250 V AC G.U. (same polarity) 6A 24 V DC G. U. 6A B300, R300 250 V AC G.U. (same polarity) 6A 24 V DC G. U.
Relays for functional safety Safety relays PNOZ X PZE X4VP Times 787580 787581 Supply interruption before de-energisation 1.500 ms 250 ms 500 ms Environmental data 777583 787580 787581 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PZE X4VP Mechanical data Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Strip
Relays for functional safety Safety relays PNOZ X PZE X4VP Order no. 787582 – 787583 General 787582 787583 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 787582 787583 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 2,5 W 20 % 100 % 2,5 W 20 % 100 % 1,7 A 140 ms 1,7 A 180 ms Inputs 787582 787583 Number Voltage at Input circuit DC Current at Input circuit DC Max.
Relays for functional safety Safety relays PNOZ X PZE X4VP Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard External contact fuse protection, delayed safety contacts Max.
Relays for functional safety Safety relays PNOZ X PZE X4VP Times Switch-on delay With automatic start after power on typ. With automatic start after power on max. Delay time tv Time accuracy Supply interruption before de-energisation 787582 787583 55 ms 55 ms 200 ms 2s -50 %/+50 % 200 ms 3s -50 %/+50 % 1.000 ms 1.
Relays for functional safety Safety relays PNOZ X PZE X4VP Mechanical data 787582 787583 Connection type Mounting type Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight Spring-loaded terminal plug-in Spring-loaded terminal plug-in 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 2 2 8 mm 8 mm 101 mm 22,5 mm 121
Relays for functional safety Safety relays PNOZ X PZE X4VP Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 VDC and 230 VAC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Number of cycles x 1000 Safety relays PNOZ X PZE X4VP Switching current (A) Fig.: Service life graphs at 110 VDC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 438]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts.
Relays for functional safety Safety relays PNOZ X PZE X4VP Order reference Type Features Connection type PZE X4VP 24 V DC; tV = 0.5 s Screw terminals, plug-in Order no. 777580 PZE X4VP C 24 V DC; tV = 0.
Relays for functional safety Safety relays PNOZ X PZE X4VP4 PZE X4VP4 Unit features } Positive-guided relay outputs: – } 4 safety contacts (N/O), delay-on de-energisation LED display for: – Switch status of the safety contacts } Connection for feedback loop } Operation: single-channel } Selectable delay time } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Block diagram/terminal configuration * 4A 3A 2A 1A 4B 3B 2B 1B De
Relays for functional safety Safety relays PNOZ X PZE X4VP4 Function description The contact expansion module PZE X4VP4 is an add-on device with selectable delay-on de-energisation, and it is used to expand a safety circuit. The contact expansion module is driven by a base unit (e. g. emergency stop relay). } } Functional procedure once the input circuit is closed (e.g. safety contacts on the base unit are closed): – The supply voltage is present at input (A1) of the contact expansion module.
Relays for functional safety Safety relays PNOZ X PZE X4VP4 } The power supply must comply with the regulations for extra low voltages with protective electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410. } Ensure the wiring and EMC requirements of IEC 60204-1 are met.
Relays for functional safety Safety relays PNOZ X PZE X4VP4 Dimensions in mm * with spring-loaded terminals Technical details General 777586 787586 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 777586 787586 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 2,5 W 20 % 100 % 2,5 W 20 % 100 % 1,7 A 180 ms 1,7 A 180 ms Inputs 777586 787586 Number Voltage at Input circuit DC Current at Input circuit DC 1 1 24 V 24 V 70 mA 70 mA S
Relays for functional safety Safety relays PNOZ X PZE X4VP4 Inputs 777586 787586 Max. overall cable resistance Rlmax Single-channel at UB DC 30 Ohm 30 Ohm Relay outputs 777586 787586 4 1 kA 4 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 5A 1200 VA 24 V 0,01 A 5A 120 W 240 V 0,01 A 5A 1200 VA 24 V 0,01 A 5A 120 W EN 60947-5-1 EN 60947-5-1 230 V 5A 24 V 4A 230 V 5A 24 V 4A 240 V AC G.U. (same polarity) 5A 24 V DC Resistive 5A B300, R300 240 V AC G.U.
Relays for functional safety Safety relays PNOZ X PZE X4VP4 Relay outputs 777586 787586 100 A²s 6A 4A 6A 100 A²s 6A 4A 6A 4A 5A AgSnO2 + 0,2 µm Au 4A 5A AgSnO2 + 0,2 µm Au 777586 787586 230 ms 230 ms 400 ms 1 s, 2 s, 3 s, 4 s -50 %/+50 % 400 ms 1 s, 2 s, 3 s, 4 s -50 %/+50 % 500 ms 500 ms Environmental data 777586 787586 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068
Relays for functional safety Safety relays PNOZ X PZE X4VP4 Environmental data 777586 787586 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PZE X4VP4 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, delayed <30 PL d s Cat. 3 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 2 2,48E-09 SIL 2 1,47E-05 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PZE X4VP4 Service life graph Switching current (A) The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible.
Relays for functional safety Safety relays PNOZ X PZE X4VP8 PZE X4VP8 Unit features } Positive-guided relay outputs: – } 4 safety contacts (N/O), delay-on de-energisation LED display for: – Switch status of the safety contacts } Connection for feedback loop } Operation: single-channel } Selectable delay time } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Block diagram/terminal configuration * 8A 7A 6A 5A 8B 7B 6B 5B De
Relays for functional safety Safety relays PNOZ X PZE X4VP8 Function description The contact expansion module PZE X4VP8 is an add-on device with selectable delay-on de-energisation, and it is used to expand a safety circuit. The contact expansion module is driven by a base unit (e. g. emergency stop relay). } } Functional procedure once the input circuit is closed (e.g. safety contacts on the base unit are closed): – The supply voltage is present at input (A1) of the contact expansion module.
Relays for functional safety Safety relays PNOZ X PZE X4VP8 } The power supply must comply with the regulations for extra low voltages with protective electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410. } Ensure the wiring and EMC requirements of IEC 60204-1 are met.
Relays for functional safety Safety relays PNOZ X PZE X4VP8 Dimensions in mm * with spring-loaded terminals Technical details General 777584 787584 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 777584 787584 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 2,5 W 20 % 100 % 2,5 W 20 % 100 % 1,7 A 280 ms 1,7 A 280 ms Inputs 777584 787584 Number Voltage at Input circuit DC Current at Input circuit DC 1 1 24 V 24 V 70 mA 70 mA S
Relays for functional safety Safety relays PNOZ X PZE X4VP8 Inputs 777584 787584 Max. overall cable resistance Rlmax Single-channel at UB DC 30 Ohm 30 Ohm Relay outputs 777584 787584 4 1 kA 4 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 5A 1200 VA 24 V 0,01 A 5A 120 W 240 V 0,01 A 5A 1200 VA 24 V 0,01 A 5A 120 W EN 60947-5-1 EN 60947-5-1 230 V 5A 24 V 4A 230 V 5A 24 V 4A 240 V AC G.U. (same polarity) 5A 24 V DC Resistive 5A B300, R300 240 V AC G.U.
Relays for functional safety Safety relays PNOZ X PZE X4VP8 Relay outputs 777584 787584 100 A²s 6A 4A 6A 100 A²s 6A 4A 6A 4A 5A AgSnO2 + 0,2 µm Au 4A 5A AgSnO2 + 0,2 µm Au 777584 787584 320 ms 320 ms 500 ms 5 s, 6 s, 7 s, 8 s -50 %/+50 % 500 ms 5 s, 6 s, 7 s, 8 s -50 %/+50 % 2.500 ms 2.
Relays for functional safety Safety relays PNOZ X PZE X4VP8 Environmental data 777584 787584 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZ X PZE X4VP8 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, delayed <30 PL d s Cat. 3 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 2 2,48E-09 SIL 2 1,47E-05 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PZE X4VP8 Service life graph Switching current (A) The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible.
Relays for functional safety Safety relays PNOZ X PZE X5P PZE X5P Unit features } Positive-guided relay outputs: – 5 safety contacts (N/O), instantaneous } 2 semiconductor outputs } LED display for: } – Supply voltage – Switch status of the safety contacts Semiconductor outputs signal: – Supply voltage is present – Switch status of the safety contacts } Connection for feedback loop } Operation: single or dual-channel Block diagram/terminal configuration * *Insulation between the non-m
Relays for functional safety Safety relays PNOZ X PZE X5P Function description The contact expansion module PZE X5P is an add-on device without delay-on de-energisation, and it is used to expand a safety circuit. The contact expansion module is driven by a base unit (e. g. emergency stop relay). When operating voltage is supplied the "POWER" LED will light. } } Functional procedure once the input circuit is closed (e.g.
Relays for functional safety Safety relays PNOZ X PZE X5P } Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. } Do not switch low currents using contacts that have been used previously with high currents. } The power supply must comply with the regulations for extra low voltages with protective electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410. } Ensure the wiring and EMC requirements of IEC 60204-1 are met.
Relays for functional safety Safety relays PNOZ X PZE X5P Dimensions in mm * with spring-loaded terminals Technical details General 777150 787150 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 777150 787150 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 3,5 W 20 % 100 % 3,5 W 20 % 100 % 10 A 0,5 ms 10 A 0,5 ms Inputs 777150 787150 Number Voltage at Input circuit DC Current at Input circuit DC 2 2 24 V 24 V 40 mA 40 mA Suppl
Relays for functional safety Safety relays PNOZ X PZE X5P Inputs 777150 Max.
Relays for functional safety Safety relays PNOZ X PZE X5P Relay outputs Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv.
Relays for functional safety Safety relays PNOZ X PZE X5P Times 777150 787150 15 ms 30 ms 110 ms 150 ms 15 ms 30 ms 110 ms 150 ms 8 ms 8 ms 20 ms 20 ms Environmental data 777150 787150 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PZE X5P Mechanical data Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring
Relays for functional safety Safety relays PNOZ X PZE X5P Supplementary data The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components.
Relays for functional safety Safety relays PNOZ X PZE X5P Order reference Type Features Terminals Order no. PZE X5P C 24 V DC Spring-loaded terminals 787 150 PZE X5P 24 V DC Screw terminals 777 150 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PZE 9P PZE 9P Unit features } } Positive-guided relay outputs: – 8 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous LED display for: – Supply voltage – Switch status of the safety contacts } Connection for feedback loop } Operation: Single or dual-channel } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Block diagram/terminal configuration
Relays for functional safety Safety relays PNOZ X PZE 9P Type: 24 - 240 V AC/DC } UB: 24 - 240 VAC/DC, 24 VAC/DC; Order no. 777148, 787148 *Safe separation from non-marked area, except for safety contact 13-14, in accordance with EN 60947-1, 6 kV, basic insulation between all safety contacts. Function description The contact expansion module PZE 9P is an add-on device without delay-on de-energisation. It is used to expand a safety circuit. The contact expansion module is driven by a base unit (e. g.
Relays for functional safety Safety relays PNOZ X PZE 9P Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74, 83-84 are safety contacts; output 91-92 is an auxiliary contact (e.g. for display). } Do not use auxiliary contact 91-92 for safety circuits! } Do not connect undesignated terminals. } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 486]).
Relays for functional safety Safety relays PNOZ X PZE 9P Preparing for operation Supply voltage Order no.: 777148, 787148 24 - 240 V AC/DC 24 VAC/DC A1 L1 A2 N FE B1 L1/L+ B2 N/L- Order no.
Relays for functional safety Safety relays PNOZ X PZE 9P 121 (4.76") Dimensions in mm 90 (3.54") 75 (2.95") 87 (3.42") Technical details Order no.
Relays for functional safety Safety relays PNOZ X PZE 9P Inputs Max.
Relays for functional safety Safety relays PNOZ X PZE 9P Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PZE 9P Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Conv. therm. current with 5 contacts Conv. therm. current with 6 contacts Conv. therm. current with 7 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PZE 9P Times 777140 787140 20 ms 30 ms 110 ms 200 ms 20 ms 30 ms 110 ms 200 ms 10 ms 10 ms 20 ms 20 ms Environmental data 777140 787140 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PZE 9P Mechanical data Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-
Relays for functional safety Safety relays PNOZ X PZE 9P Order no.
Relays for functional safety Safety relays PNOZ X PZE 9P Inputs Max.
Relays for functional safety Safety relays PNOZ X PZE 9P Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PZE 9P Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Conv. therm. current with 5 contacts Conv. therm. current with 6 contacts Conv. therm. current with 7 contacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PZE 9P Times 777148 787148 20 ms 30 ms 200 ms 310 ms 500 ms 20 ms 30 ms 200 ms 310 ms 500 ms 630 ms 150 ms 200 ms 630 ms 150 ms 200 ms 10 ms 10 ms 20 ms 20 ms Environmental data 777148 787148 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PZE 9P Mechanical data 777148 787148 Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible wit
Relays for functional safety Safety relays PNOZ X PZE 9P Safety characteristic data Operating Mode – EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZ X PZE 9P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PMUT X1P PMUT X1P Unit features } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } 4 inputs for muting sensors } 1 ESPE input for light grids (2-channel, contact or semiconductor outputs) } 1 input for additional safety light grid (2-channel, contact outputs) or safety contacts } Connection option for 2 muting lamps } Connection options for: – Start button – Key switch –
Relays for functional safety Safety relays PNOZ X PMUT X1P } See order reference for unit types Block diagram/terminal configuration d ib csh alkBto l *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PMUT X1P Function description The muting controller PMUT X1P is used for the temporary suspension of safety functions. This allows objects to be transported into and out of a danger zone without adversely affecting the safety function. When the supply voltage is applied the "POWER" LED will light. The unit is ready for operation when the feedback loop Y1-Y2 and the input circuit (e.g. light guard at S12 and S22 not interrupted) are closed.
Relays for functional safety Safety relays PNOZ X PMUT X1P Timing diagram [2] [4] [1] [3] [6] [5] [4] [3] ESPE Legend } Power: Supply voltage } Start: Start button } ESPE: Light guard } MS1 ...
Relays for functional safety Safety relays PNOZ X PMUT X1P Operating modes } Dual-channel operation (contact or semiconductor outputs from ESPE) without detection of shorts across contacts } Dual-channel operation (contact or semiconductor outputs from ESPE) with detection of shorts across contacts: redundant input circuit, earth faults in the input circuit or shorts across the input circuits are detected.
Relays for functional safety Safety relays PNOZ X PMUT X1P } Parallel muting with 4 muting sensors Muting lamp MS1 AOPD MS3 Danger zone MS2 AOPD MS4 } Sequential muting with 4 muting sensors Muting lamp MS1 MS2 AOPD MS3 MS4 Danger zone AOPD Muting sensors MS1 and MS2 must energise within 3 s (simultaneity). Muting starts when both muting sensors are active. The inputs of light guards S11-S12, S21-S22 and S31-S32 are muted. Status indicators "S1+S2" (Muting active), "S1", "S2" "OSSD CH.
Relays for functional safety Safety relays PNOZ X PMUT X1P MS1 MS2 MS3 MS4 ML1 Muting max. 2 x delay on de-energisation Legend: MS1: Muting sensor 1 MS2: Muting sensor 2 MS3: Muting sensor 3 MS4: Muting sensor 4 ML1: Muting lamp 1 Reset input If the simultaneity requirement of 3 s is exceeded, the unit will go to a fault condition. Once the fault has been rectified, the simultaneity must be reset by operating the key switch at S43-S44. The start button S33-34 must then be operated.
Relays for functional safety Safety relays PNOZ X PMUT X1P Muting lamps The muting controller PMUT X1P is designed for use with one or two muting lamps. As soon as the inputs of the light guard are muted, the Muting lamp ML1 will light. The PMUT X1P monitors the connected muting lamps during the muting cycle. If muting lamp ML1 is defective (e.g. coiled filament broken or lamp switched off), then the PMUT X1P automatically switches to muting lamp ML2.
Relays for functional safety Safety relays PNOZ X PMUT X1P } Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. } Do not switch low currents using contacts that have been used previously with high currents. } Ensure the wiring and EMC requirements of IEC 60204-1 are met. } Mechanical and optoelectronic sensors (safety light beam devices, safety light grids) are suitable for use.
Relays for functional safety Safety relays PNOZ X PMUT X1P Preparing for operation Supply voltage Input circuit AC Semiconductor DC A1 L+ A2 L- Contacts Muting sensors Light grid (ESPE) Semiconductor output 2 x PNP Detection of shorts across contacts via light grid Light grid (ESPE) Semiconductor output PNP/NPN Detection of shorts across contacts; - Semiconductor: via light grid - Contacts: via PMUT X1P Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PMUT X1P Input circuit Semiconductor Contacts Additional light grid, 2-channel, ESTOP pushbutton Muting lamp LA+ LALB+ LB- Start circuit S1: Key switch S3: Start button Feedback loop without feedback loop monitoring with feedback loop monitoring Link or contacts from external contactors Semiconductor output Y32: Light grid active Y33: Muting active Y34: Muting lamp warning Y35: Both muting lamps defective Y36: Safety contacts closed Pilz GmbH & Co
Relays for functional safety Safety relays PNOZ X PMUT X1P Application example +24 V DC 23 33 A2 S3+ S3 S4+ S4 LB+ LB- S43 S44 Y1 Y2 S11 S12 14 24 34 A1 S1+ S1 S2+ S2 LA+ LA- S33 S34 S21 S22 S31 S32 13 S1 S2 PMUT X1P OSSD2 OSSD1 S3 S4 K6 K5 K5 K6 0V Dimensions in mm * With spring-loaded terminals Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZ X PMUT X1P Technical details General 778010 788010 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 778010 788010 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 33 W 6W 48 % 100 % 33 W 6W 48 % 100 % 24 V 24 V 24 V 24 V 24 V 24 V 500 mA 40 mA 40 mA 500 mA 40 mA 40 mA 0,96 W 0,96 W 5W 10 W 12 W 5W 10 W 12 W Inputs 778010 788010 Number Voltage at Input circuit DC Start circuit DC Fee
Relays for functional safety Safety relays PNOZ X PMUT X1P Inputs 778010 Max.
Relays for functional safety Safety relays PNOZ X PMUT X1P Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZ X PMUT X1P Conventional thermal current while loading several contacts 778010 Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact 8A Conv. therm. current with 2 con6A tacts Conv. therm.
Relays for functional safety Safety relays PNOZ X PMUT X1P Environmental data 778010 788010 -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 61000-6-2, EN 61326-3-1, EN 61496-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PMUT X1P Mechanical data Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 778010 788010 – 0,2 - 1,5 mm², 24 - 16 AWG – 2 – 8 mm 94 mm 90 mm 121 mm 565 g 101 mm 90 mm 121 mm 565 g Where standards are undated, the 2014-07 latest editions shall apply.
Relays for functional safety Safety relays PNOZ X PMUT X1P Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZ X PSWZ X1P PSWZ X1P Unit features } Measuring inputs for 3- or 1-phase motors } Measuring voltage on both channels can be set jointly } 1 Reset input } Positive-guided relay outputs: – 2 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } 2 semiconductor outputs } LED display for: } – Standstill on channel 1/2 – Supply voltage/fault Semiconductor outputs signal: – Supply voltage/fault – Switch status } F
Relays for functional safety Safety relays PNOZ X PSWZ X1P Block diagram/terminal configuration **Insulation against the non-marked area and between the relay contacts: Basic insulation (overvoltage category III), protective separation (overvoltage category II); at 250 V, 4 kV ***Insulation against the non-marked area and between the measurement connections: Basic insulation (overvoltage category III), protective separation (overvoltage category II); at 690 V, 6 kV } Channel 1: L1-L3 } Channel 2: L2-L3
Relays for functional safety Safety relays PNOZ X PSWZ X1P } Procedure when after the motor has started, the voltage in one of the two measuring circuits exceeds the release value Uoff: – Safety contacts 13-14 and 23-24 are opened redundantly, auxiliary contact 41-42 is closed. – A low signal is present at semiconductor output Y32. – LEDs "CH.1 IN", "CH.2 IN" and "OUTPUT" go out.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Timing diagram Feedback loop Output Legend } POWER: Supply voltage } UL1/UL2: Input circuit L1, L2, L3 } Feedback loop: Feedback loop Y1-Y2 } Output safe: Safety contacts 13-14, 23-24 } Output aux: Auxiliary contact 41-42 } Output Y35: Semiconductor output for fault signal } RESET: Reset input } Uon: Response value } Uoff: Release value } tg: Simultaneity Installation } The unit should be installed in a control cabinet with
Relays for functional safety Safety relays PNOZ X PSWZ X1P Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24 are safety contacts, the output 41-42 is an auxiliary contact (e.g. for display). } Auxiliary contact 41-42 should not be used for safety circuits! } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 527]). } Calculation of the max.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Preparing for operation Connection Supply voltage Input circuit Single-phase motor = singlephase measurement signal evaluation AC DC A1 L1 A1 L+ A2 N A2 L- Single-phase motor Three-phase motor F2 F2 Three-phase motor = two-phase measurement signal evaluation PSWZ X1P PSWZ X1P Single-phase measurement signal evaluation F2 PSWZ X1P Feedback loop with feedback loop monitoring without feedback loop monitoring Contacts from externa
Relays for functional safety Safety relays PNOZ X PSWZ X1P Semiconductor input Set standstill detection } Turn the potentiometer to the left-hand stop (default setting) } Set standstill detection } – At motor standstill, the LEDs "CH.1 IN" and "CH.2 IN" must light up. If the LEDs do not light in the default setting, turn the potentiometer gradually to the right until the LEDs "CH.1 IN" and "CH.2 IN” light up. – If the simultaneity requirement is met, the "OUTPUT” LED will also light up.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Application example L1 L2 L3 A1 S31 S32 13 23 33 41 S11 S12 S13 S14 S21 S22 S33 S34 PNOZ X3P A2 Y30 Y31 Y32 14 24 34 42 PSWZ X1P N Standstill detection only with closed star contactor contacts Legend } S0: Off switch } S1: On switch } S2/S4: Safety gate switch } S3: Release } S5: Reset button } K1: Star/delta control relay } K2: Motor contactor } K3: Delta contactor } K4: Star contactor } H: Fault indicator Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZ X PSWZ X1P } : Operated element } : Gate open } : Gate closed Dimensions in mm * with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Electrical data 777949 777950 Max. inrush current at UB Duty cycle 10 A 100 % 10 A 100 % Measuring circuit 777949 777950 Min. measuring voltage Max. measuring voltage Measuring voltage in accordance with UL Frequency range Input resistance Switching threshold per channel Response value Uon (adjustable) Release value Uoff 0,0 V 690 V 0,0 V 690 V 600 V 0 - 3 kHz 1.300 kOhm 600 V 0 - 3 kHz 1.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Environmental data 777949 777950 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61000-6-4, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Mechanical data Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Dimensions Height Width Depth Weight 777949 777950 0,25 - 2,5 mm², 24 - 14 AWG 0,25 - 2,5 mm², 24 - 14 AWG 0,25 - 1 mm², 24 - 16 AWG 0,25 - 1 mm²,
Relays for functional safety Safety relays PNOZ X PSWZ X1P Measuring circuit 777951 777959 600 V 0 - 3 kHz 1.300 kOhm 600 V 0 - 3 kHz 1.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Environmental data 777951 777959 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61000-6-4, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Mechanical data Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Dimensions Height Width Depth Weight 777951 777959 0,25 - 2,5 mm², 24 - 14 AWG 0,25 - 2,5 mm², 24 - 14 AWG 0,25 - 1 mm², 24 - 16 AWG 0,25 - 1 mm²,
Relays for functional safety Safety relays PNOZ X PSWZ X1P Measuring circuit 787949 787950 787951 Frequency range Input resistance Switching threshold per channel Response value Uon (adjustable) Release value Uoff 0 - 3 kHz 1.300 kOhm 0 - 3 kHz 1.300 kOhm 0 - 3 kHz 1.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Times 787949 787950 787951 Simultaneity, channel 1 and 2 max. 7s 7s 7s Environmental data 787949 787950 787951 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C 93 % r. h.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Mechanical data Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 787949 787950 787951 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 0,2 - 1,5 mm², 24 - 16 AWG 2 2 2 8 mm 8 mm 8 mm 101 mm 45 mm 121 mm 325 g 101 mm 45 mm 121 mm 325 g 101 mm 45 mm 12
Relays for functional safety Safety relays PNOZ X PSWZ X1P Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 VDC and 230 VAC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Number of cycles x 1000 Safety relays PNOZ X PSWZ X1P Switching current (A) Fig.: Service life graphs at 110 VDC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 527]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts.
Relays for functional safety Safety relays PNOZ X PSWZ X1P Order reference Type Features Connection type Order no.
Relays for functional safety Safety relays PNOZsigma Safety relays PNOZsigma Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma Contents Page PNOZ s1 548 PNOZ s2 559 PNOZ s3 573 PNOZ s4 588 PNOZ s4.1 614 PNOZ s5 634 PNOZ s6 661 PNOZ s6.1 682 PNOZ s7 703 PNOZ s7.1 716 PNOZ s7.2 730 PNOZ s8 742 PNOZ s9 752 PNOZ s10 769 PNOZ s11 781 PNOZ s20 792 PNOZ s22 801 PNOZ s30 810 PNOZ s50 893 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s1 PNOZ s1 Unit features } Relay outputs: – 2 safety contacts (N/O), instantaneous } 1 semiconductor output } Connection options for: – E-STOP pushbutton – Safety gate limit switch – Start button } A connector can be used to connect 1 PNOZsigma contact expansion module } LED indicator for: – Supply voltage – Input status, channel 1 – Input status, channel 2 – Switch status of the safety contacts – Start circuit – Errors }
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Interface expansion module Block diagram/terminal configuration Fig.: Centre: Front view with cover, right: Front view without cover *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Function description } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected.
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Timing diagram [1] [2] Start Legend } POWER: Supply voltage } Start: Start circuit } Input: Input circuits } Output safe: Safety contacts } Semi: Semiconductor output } [1]: Automatic start } [2]: Manual start } a: Input circuit closes before start circuit } b: Start circuit closes before input circuit } t1: Switch-on delay } t2: Delay-on de-energisation } t3: Recovery time Installation Install base unit without contac
Relays for functional safety Safety relays PNOZsigma PNOZ s1 } When installed vertically: Secure the unit by using a fixing element (e.g. retaining bracket or end angle). } Push the device upwards or downwards before lifting it from the DIN rail. Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14 and 23-24 are safety contacts, the semiconductor output Y32 is an auxiliary output (e.g. for display).
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Preparing for operation Supply voltage AC DC S1 Input circuit Single-channel E-STOP without detection of shorts across contacts L+ A2 L- Dual-channel S1 L+ A1 Safety gate without detection of shorts across contacts S1 L+ A1 Start circuit/feedback loop A1 Start circuit Feedback loop Automatic start A1 S34 13 (23) 14 (24) K5 K6 L1 K5 N K6 Manual start S3 A1 A1 S34 S34 13 (23) 14 (24) S3 K5 K6 K5 L1 N K6 Pilz GmbH &
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Semiconductor output *Connect together the 0V connections on all the external power supplies Key } S1: E-STOP pushbutton } S3: Start button } : Switch operated } : Gate open } : Gate closed Dimensions in mm 120 (4.72") *with spring-loaded terminals 98 (3.86") 12,5 (0.69") * 100 (3,94") Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Technical Details General 750101 751101 Approvals CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed Electrical data 750101 751101 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 2W 20 % 100 % 2W 20 % 100 % Inputs 750101 751101 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Relay outputs 750101 751101 Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Times 750101 751101 100 ms 150 ms 100 ms 150 ms 100 ms 100 ms 150 ms 50 ms 60 ms 150 ms 50 ms 60 ms 30 ms 40 ms 30 ms 40 ms 30 ms 40 ms 30 ms 40 ms 100 ms 100 ms 100 ms 100 ms 10 ms 10 ms Environmental data 750101 751101 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 -
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Environmental data 750101 751101 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZsigma PNOZ s1 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL c Cat. 3 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 2 2,00E-07 SIL 2 5,95E-03 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 PNOZ s2 Unit features } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } Protective separation of safety contacts from all other circuits } 1 semiconductor output } Connection options for: – E-STOP pushbutton – Safety gate limit switch – Start button } A connector can be used to connect 1 PNOZsigma contact expansion module } Operating modes can be set via rota
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Interface expansion module Block diagram/terminal configuration Fig.: Centre: Front view with cover, right: Front view without cover *Safe separation from non-marked area in accordance with EN 60947-1, 6 kV, basic insulation between all safety contacts. Function description } Single-channel operation: No redundancy in the input circuit, earth faults in the start and input circuit are detected.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Timing diagram [1] [2] [3] [4] Legend } Power: Supply voltage } Start: Start circuit } Input: Input circuits } Output safe: Safety contacts } Output aux: Auxiliary contacts } Out semi: Semiconductor output } [1]: Automatic start } [2]: Manual start } [3]: Monitored start with rising edge } [4]: Monitored start with falling edge } a: Input circuit closes before start circuit } b: Start circuit closes before input circuit
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Installation Install base unit without contact expansion module: } Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and PNOZsigma contact expansion module: } Remove the plug terminator at the side of the base unit and at the contact expansion module. } Connect the base unit and the contact expansion module to the supplied connector before mounting the units to the DIN rail.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Preparing for operation Operating modes The operating mode is set via the rotary switch on the unit. You can do this by opening the cover on the front of the unit. Set operating modes } Switch off supply voltage. } Select operating mode via the operating mode selector switch "mode". } If the operating mode selector switch "mode" is in its start position (vertical position), an error message will appear.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Start circuit/feedback loop Without feedback loop monitoring With feedback loop monitoring Automatic start A1 S34 13 (23,33) 14 (24,34) K5 K6 L1 K5 N K6 Monitored, manual start/restart S3 A1 A1 S34 13 (23,33) 14 (24,34) S34 S3 K5 K6 K5 L1 N K6 Semiconductor output *Connect together the 0V connections on all the external power supplies Dimensions in mm 120 (4.72") *with spring-loaded terminals 98 (3.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Technical Details General 750102 751102 Approvals CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed Electrical data 750102 751102 24 V DC -15 %/+10 % 24 V DC -15 %/+10 % 2W 20 % 100 % 2W 20 % 100 % Inputs 750102 751102 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Auxiliary contacts (N/C) Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Relay outputs Utilisation category in accordance with UL Voltage With current Voltage With current External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Times 750102 751102 75 ms 250 ms 75 ms 250 ms 75 ms 75 ms 250 ms 75 ms 250 ms 250 ms 75 ms 250 ms 75 ms 75 ms 250 ms 250 ms 55 ms 55 ms 70 ms 70 ms 50 ms 70 ms 50 ms 70 ms 50 ms 70 ms 50 ms 70 ms 100 ms 100 ms 100 ms 100 ms 100 ms 110 ms 100 ms 110 ms 100 ms 100 ms 100 ms 100 ms 10 ms 10 ms Environmental data 750102 751102 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature rang
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Environmental data 750102 751102 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61000-6-4, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Mechanical data Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 750102 751102 – 2 – 9 mm 98 mm 17,5 mm 120 mm 175 g 100 mm 17,5 mm 120 mm 175 g Where standards are undated, the 2014-07 latest editions shall apply.
Relays for functional safety Safety relays PNOZsigma PNOZ s2 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s2 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 565]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 PNOZ s3 Unit features } Positive-guided relay outputs: – 2 safety contacts (N/O), instantaneous } 1 semiconductor output } Connection options for: – E-STOP pushbuttons – Safety gate limit switches – Start buttons – Light grids and safety switches with detection of shorts across contacts } A connector can be used to connect 1 PNOZsigma contact expansion module } Operating modes can be set via rotary switch } LED indicator for:
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Interface expansion module Block diagram/terminal configuration Fig.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 } Monitored start with rising edge: Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed (see technical details). } Start with start-up test: The unit checks whether safety gates that are closed are opened and then closed again when supply voltage is applied.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Installation Install base unit without contact expansion module: } Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and PNOZsigma contact expansion module: } Remove the plug terminator at the side of the base unit and at the contact expansion module. } Connect the base unit and the contact expansion module to the supplied connector before mounting the units to the DIN rail.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Preparing for operation Operating modes The operating mode is set via the rotary switch on the unit. You can do this by opening the cover on the front of the unit. Set operating modes } Switch off supply voltage. } Select operating mode via the operating mode selector switch "mode". } If the operating mode selector switch "mode" is in its start position (vertical position), an error message will appear.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Connection Supply voltage Input circuit AC DC Single-channel E-STOP L+ A2 L- Dual-channel S1 S1 S11 without detection of shorts across contacts A1 S11 S12 S22 S12 S22 E-STOP S1 S11 with detection of shorts across contacts S21 S22 S12 Safety gate without detection of shorts across contacts S1 S11 S11 S12 S22 S1 S2 S12 S22 Safety gate with detection of shorts across contacts S11 S1 S12 S21 S22 Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Input circuit Single-channel Dual-channel Light beam device or safety switch, detection of shorts across contacts via ESPE 24 V DC A1 A2 S12 S22 GND Start circuit/feedback loop Without feedback loop monitoring with feedback loop monitoring Automatic start S12 S34 13 (23) 14 (24) K5 K6 L1 K5 N K6 Monitored, manual start/restart S3 S12 S12 S34 S34 13 (23) 14 (24) S3 K5 K6 K5 L1 N K6 Semiconductor output *Connect together t
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Dimensions in mm 120 (4.72") *with spring-loaded terminals 98 (3.86") 17,5 (0.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Inputs 750103 751103 50 mA 50 mA 50 mA 50 mA 50 mA 50 mA 0,2 A 100 ms 0,2 A 15 ms 0,2 A 15 ms 110 Ohm 0,2 A 100 ms 0,2 A 15 ms 0,2 A 15 ms 110 Ohm 30 Ohm 30 Ohm 60 Ohm 60 Ohm 30 Ohm 30 Ohm Semiconductor outputs 750103 751103 Number Voltage Current 1 24 V 20 mA 1 24 V 20 mA Relay outputs 750103 751103 2 1 kA 2 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Times 750103 751103 10 ms 20 ms 40 ms 60 ms 10 ms 20 ms 40 ms 60 ms 100 ms 100 ms 100 ms 100 ms 120 ms 250 ms 120 ms 250 ms 30 ms 100 ms 30 ms 100 ms 20 ms ∞ 20 ms ∞ Environmental data 750103 751103 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Environmental data 750103 751103 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZsigma PNOZ s3 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s3 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 580]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 PNOZ s4 Unit features } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } 1 semiconductor output } Connection options for: – E-STOP pushbuttons – Safety gate limit switches – Start buttons – Light grids and safety switches with detection of shorts across contacts } A connector can be used to connect 1 PNOZsigma contact expansion module } Operating modes can be
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Block diagram/terminal configuration Unit types with UB 24 VDC UB: 24 VDC; Order no. 750104, 751104, 751184 Interface expansion module } Fig.: Centre: Front view with cover, right: Front view without cover *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Unit types with UB 48 - 240 VAC/DC UB: 48 - 240 VAC/DC; Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Function description In2+ } Single-channel operation: no redundancy in the input circuit, earth faults in the start circuit and input circuit are detected. } Dual-channel operation without detection of shorts across contacts: Redundant input circuit, detects PNOZ s4 } – earth faults in the start and input circuit, – short circuits in the input circuit and, with a monitored start, in the start circuit too.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Timing diagram [1] [2] [3] [4] Legend } POWER: Supply voltage } Start: Start circuit } Input: Input circuits } Output safe: Safety contacts } Output aux: Auxiliary contacts } Out semi: Semiconductor output } [1]: Automatic start } [2]: Manual start } [3]: Monitored start with rising edge } [4]: Monitored start with falling edge } a: Input circuit closes before start circuit } b: Start circuit closes before input circuit
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Installation Install base unit without contact expansion module: } Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and PNOZsigma contact expansion module: } Remove the plug terminator at the side of the base unit and at the contact expansion module. } Connect the base unit and the contact expansion module to the supplied connector before mounting the units to the DIN rail.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 } On 24 VDC devices: The power supply must comply with the regulations for extra low voltages with protective electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410. Preparing for operation Operating modes The operating mode is set via the rotary switch on the unit. You can do this by opening the cover on the front of the unit. Set operating modes } Switch off supply voltage.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Connection Supply voltage Input circuit E-Stop without detection of shorts across contacts Unit types with UB 24 VDC Unit types with UB 48 - 240 VAC/DC A1 L+ A2 L- Single-channel Dual-channel S1 S1 S11 S11 S12 S12 S22 S22 E-Stop S1 S11 with detection of shorts across contacts S21 S22 S12 Safety gate without detection of shorts across contacts S1 S11 S11 S1 S12 S22 S2 S12 S22 Safety gate with detection of shorts across co
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Without feedback loop Start circuit/feedback loop monitoring With feedback loop monitoring Automatic start S12 S34 13 (23,33) 14 (24,34) K6 K5 L1 K5 N K6 Monitored, manual start/restart S3 S12 S12 S34 S34 13 (23,33) 14 (24,34) S3 K5 K6 K5 L1 N K6 Unit types with UB 24 VDC Unit types with UB 48 - 240 VAC/DC *Connect together the 0V connections on all the external power supplies Legend } S1/S2: E-STOP/safety gate switch } S3:
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Dimensions in mm *with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Electrical data 750104 750134 751104 Max. inrush current impulse Current pulse, A1 Pulse duration, A1 0,5 A 5 ms – – 0,5 A 5 ms Inputs 750104 750134 751104 Number Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Inputs 750104 750134 751104 30 Ohm 30 Ohm 30 Ohm – 30 Ohm – 60 Ohm 30 Ohm 60 Ohm – 30 Ohm – 30 Ohm 30 Ohm 30 Ohm – 30 Ohm – Semiconductor outputs 750104 750134 751104 Number Voltage Current 1 24 V 20 mA 1 24 V 20 mA 1 24 V 20 mA Relay outputs 750104 750134 751104 3 1 3 1 3 1 1 kA 1 kA 1 kA EN 60947-4-1 EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,0
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Times 750104 750134 751104 170 ms 170 ms 170 ms 300 ms 300 ms 300 ms 350 ms 350 ms 350 ms 600 ms 40 ms 600 ms 40 ms 600 ms 40 ms 35 ms 35 ms 35 ms 50 ms 50 ms 50 ms 55 ms 55 ms 55 ms 70 ms 70 ms 70 ms 10 ms 20 ms 40 ms 80 ms 10 ms 20 ms 40 ms 80 ms 10 ms 20 ms 40 ms 80 ms 100 ms 100 ms 50 ms 100 ms 100 ms 100 ms 120 ms 250 ms 120 ms 150 ms 120 ms 250 ms 30 ms 100 ms 30 ms 100 ms 30 ms 100 ms 20 ms 20 ms 2
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Environmental data 750104 750134 751104 -40 - 85 °C -40 - 85 °C -40 - 85 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Mechanical data Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Str
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Inputs 751134 751184 30 Ohm 30 Ohm 30 Ohm – 30 Ohm 60 Ohm 30 Ohm – 30 Ohm 30 Ohm 30 Ohm – Semiconductor outputs 751134 751184 Number Voltage Current 1 24 V 20 mA 1 24 V 20 mA Relay outputs 751134 751184 3 1 1 kA 3 1 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Times 751134 751184 10 ms 20 ms 40 ms 80 ms 10 ms 20 ms 40 ms 80 ms 50 ms 100 ms 100 ms 100 ms 120 ms 150 ms 120 ms 250 ms 30 ms 100 ms 30 ms 100 ms 20 ms ∞ 20 ms ∞ Environmental data 751134 751184 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -25 - 55 °C -40 - 85 °C -40 -
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Environmental data 751134 751184 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Supplementary data The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s4 Switching current (A) Fig.: Service life graphs at 110 VDC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 596]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Unit types with UB 48-240 VAC/DC UB: 48 – 240 VAC/DC; Order no. 750134, 751134 Cycles x 1000 } Switching current (A) Number of cycles x 1000 Fig.: Service life graphs at 24 VDC and 230 VAC Switching current (A) Fig.: Service life graphs at 110 VDC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s4 Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 596]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts. With capacitive loads, any power surges that occur must be noted.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 PNOZ s4.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Block diagram/terminal configuration Unit types with UB 24 VDC UB: 24 VDC; Order no. 750124, 751124 Interface expansion module } Fig.: Centre: Front view with cover, right: Front view without cover *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Unit types with UB 48 - 240 VAC/DC UB: 48 - 240 VAC/DC; Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Function description In2+ } Single-channel operation: no redundancy in the input circuit, earth faults in the start circuit and input circuit are detected. } Dual-channel operation without detection of shorts across contacts: Redundant input circuit, detects PNOZ s4.1 } – earth faults in the start and input circuit, – short circuits in the input circuit and, with a monitored start, in the start circuit too.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Installation Install base unit without contact expansion module: } Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and PNOZsigma contact expansion module: } Remove the plug terminator at the side of the base unit and at the contact expansion module. } Connect the base unit and the contact expansion module to the supplied connector before mounting the units to the DIN rail.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Preparing for operation Operating modes The operating mode is set via the rotary switch on the unit. You can do this by opening the cover on the front of the unit. Set operating modes } Switch off supply voltage. } Select operating mode via the operating mode selector switch "mode". } If the operating mode selector switch "mode" is in its start position (vertical position), an error message will appear.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Inputs Voltage at Input circuit DC Start circuit DC Feedback loop DC Current at Input circuit DC Start circuit DC Feedback loop DC Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/ min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Relay outputs Utilisation category in accordance with UL Voltage With current Voltage With current External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 2 4V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Ith per contact at UB DC; AC1: 240 V, DC1: 2 4V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max. With manual start typ. With manual start max. With monitored start with rising edge typ. With monitored start with rising edge max. With monitored start with falling edge typ. With monitored start with falling edge max. Delay-on de-energisation With E-STOP typ. With E-STOP max.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Environmental data 750124 750154 751124 751154 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Mechanical data Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 750124 750154 751124 751154 – – 9 mm 9 mm 98 mm 22,5 mm 120 mm 190 g 98 mm 22,5 mm 120 mm 210 g 100 mm 22,5 mm 120 mm 190 g 100 mm 22,5 mm 120 mm 210 g Where standards are undated, the 2014-07 latest editions shall apply.
Relays for functional safety Safety relays PNOZsigma PNOZ s4.1 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Number of cycles x 1000 Safety relays PNOZsigma PNOZ s4.1 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 622]) can be used in the calculation.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 PNOZ s5 Unit features } Positive-guided relay outputs: – 2 safety contacts (N/O), instantaneous – 2 safety contacts (N/O), delay-on de-energisation } 1 semiconductor output } Connection options for: – E-STOP pushbuttons – Safety gate limit switches – Start buttons – Light grids and safety switches with detection of shorts across contacts } A connector can be used to connect 1 PNOZsigma contact expansion module } Operating mode
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Block diagram/terminal configuration Type: 24 VDC UB: 24 VDC; Order No. 750105, 751105, 751185 Interface expansion module } Fig.: Centre: Front view with cover, right: Front view without cover *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Type: 48 - 240 VAC/DC UB: 48 – 240 VAC/DC; Order No.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Function description In2+ } Single-channel operation: no redundancy in the input circuit, earth faults in the start circuit and input circuit are detected. } Dual-channel operation without detection of shorts across contacts: Redundant input circuit, detects PNOZ s5 } – earth faults in the start and input circuit, – short circuits in the input circuit and, with a monitored start, in the start circuit too.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Timing diagrams Automatic and manual start } [1]: Automatic start } [2]: Manual start – a: Input circuit closes before start circuit – b: Start circuit closes before input circuit [1] [2] Legend } POWER: Supply voltage } Start: Start circuit } Input: Input circuits } Output safe: Safety contacts, instantaneous } Output safe del: Safety contacts, delayed } Output semi: Semiconductor output } t1: Switch-on delay } t2: Delay-
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Monitored start } } [1]: Monitored start with rising edge – a: Input circuit closes before start circuit – b: Start circuit closes before input circuit [2]: Monitored start with falling edge – a: Input circuit closes before start circuit – b: Start circuit closes before input circuit [1] [2] Legend } POWER: Supply voltage } Start: Start circuit } Input: Input circuits } Output safe: Safety contacts, instantaneous } Output saf
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Reset with start-up test Legend } POWER: Supply voltage } Start: Start circuit } Input: Input circuits } Output safe: Safety contacts, instantaneous } Output safe del: Safety contacts, delayed } Output semi: Semiconductor output } t1: Switch-on delay } t2: Delay-on de-energisation } tv: Delay time } t6: Recovery time Installation Install base unit without contact expansion module: } Ensure that the plug terminator is inserte
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24 are instantaneous safety contacts; outputs 37-38, 47-48 are delay-on de-energisation safety contacts, semiconductor output Y32 is an auxiliary output (e.g. for display). } Semiconductor output Y32 should not be used for safety circuits! } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 644]).
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Preparing for operation Operating modes and delay time The operating mode and delay time are set via the rotary switches on the unit. You can do this by opening the cover on the front of the unit. Set operating modes } Switch off supply voltage. } Select operating mode via the operating mode selector switch "mode". } If the operating mode selector switch "mode" is in its start position (vertical position), an error message will appear.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Connection Supply voltage Input circuit Unit types with UB 48 – 240 VAC/ DC Unit types with UB 24 VDC A1 L+ A2 L- Single-channel E-Stop Dual-channel S1 S1 S11 without detection of shorts across contacts S11 S12 S22 S12 S22 E-Stop S1 S11 with detection of shorts across contacts S21 S22 S12 Safety gate without detection of shorts across contacts S1 S11 S11 S12 S22 S1 S2 S12 S22 Safety gate with detection of shorts across
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Input circuit Single-channel Dual-channel Light beam device or safety switch, detection of shorts across contacts via ESPE (only on unit types with UB = 24 VDC) 24 V DC A1 A2 S12 S22 GND Start circuit/feedback loop Without feedback loop monitoring With feedback loop monitoring Automatic start Monitored, manual start/restart S3 S12 S34 Semiconductor output Unit types with UB 24 VDC Unit types with UB 48 – 240 VAC/ DC *Connect toge
Relays for functional safety Safety relays PNOZsigma PNOZ s5 } : Gate closed Dimensions in mm *with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Inputs 750105 751105 751185 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 40 mA 40 mA 40 mA 40 mA 40 mA 40 mA 40 mA 40 mA 40 mA 0,2 A 0,2 A 0,2 A 100 ms 100 ms 100 ms 0,2 A 0,2 A 0,2 A 60 ms 60 ms 60 ms 0,2 A 0,2 A 0,2 A 60 ms 60 ms 60 ms 110 Ohm 110 Ohm 110 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm Semiconductor outputs 750105 751105 751185 Number Voltage Current 1 24 V 20 mA 1
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (N/O), delayed Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Relay outputs Utilisation category of safety contacts delayed AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Conv. therm. current with 4 contacts Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Times 750105 751105 751185 Delay time tv 0,04 s, 0,1 s, 0,2 s, 0,3 s, 0,4 s, 0,5 s, 0,6 s, 0,7 s, 0,8 s, 1 s, 1,5 s, 2 s, 2,5 s, 3 s, 3,5 s, 4 s, 5 s, 6 s, 7 s, 8 s, 10 s, 12 s, 14 s, 15 s, 16 s, 20 s, 25 s, 30 s, 35 s, 40 s, 50 s, 60 s, 70 s, 80 s, 90 s, 100 s, 120 s, 140 s, 150 s, 160 s, 180 s, 200 s, 210 s, 240 s, 300 s +/-1 % + +/-20 ms +/-1 % + +/-20 ms 0,04 s, 0,1 s, 0,2 s, 0,3 s, 0,4 s, 0,5 s, 0,6 s, 0,7 s, 0,8 s, 1 s, 1,5 s, 2 s, 2,
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Environmental data 750105 751105 751185 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V EN 60947-1 III / II 2 250 V 4 kV 4 kV 4 kV IP54 IP40 IP20 IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 750105 751105 751185 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Mechanical data Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 750105 751105 751185 – 0,2 - 2,5 mm², 24 - 12 AWG 0,2 - 2,5 mm², 24 - 12 AWG – 2 2 – 9 mm 9 mm 98 mm 22,5 mm 120 mm 235 g 100 mm 22,5 mm 120 mm 235 g 100 mm 22,5 mm 120 mm 235 g Where sta
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Inputs 750135 751135 40 mA 40 mA 40 mA 40 mA 40 mA 40 mA 0,2 A 100 ms 0,2 A 60 ms 0,2 A 60 ms 110 Ohm 0,2 A 100 ms 0,2 A 60 ms 0,2 A 60 ms 110 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm 30 Ohm Semiconductor outputs 750135 751135 Number Voltage Current 1 24 V 20 mA 1 24 V 20 mA Relay outputs 750135 751135 Number of output contacts Safety contacts (N/O), instantaneous Safety contacts (
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of safety contacts delayed AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, delayed safety contacts Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max. With automatic start after power on typ. With automatic start after power on max. With manual start typ. With manual start max. With monitored start with rising edge typ. With monitored start with rising edge max. With monitored start with falling edge typ.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Times 750135 751135 150 ms 240 ms 150 ms 240 ms 30 ms 70 ms 30 ms 70 ms 20 ms ∞ 20 ms ∞ Environmental data 750135 751135 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Mechanical data Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spr
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Safety contacts, PL e delayed EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] Cat. 4 SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 Cat.
Relays for functional safety Safety relays PNOZsigma PNOZ s5 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Number of cycles x 1000 Safety relays PNOZsigma PNOZ s5 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 644]) can be used in the calculation.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 PNOZ s6 Unit features } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } 1 semiconductor output } Connection options for: – 2 control elements (pushbuttons) } A connector can be used to connect 1 PNOZsigma contact expansion module } LED for: – Supply voltage – Input status, channel 1 – Input status, channel 2 – Switch status of the safety contacts – Feedbac
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Block diagram/terminal configuration Unit types with UB 24 VDC UB: 24 VDC; Order no. 750106, 751106 Interface expansion module } Fig.: Centre: Front view with cover, right: Front view without cover *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Unit types with UB 48 - 240 VAC/DC UB: 48 - 240 VAC/DC; Order no. 750136, 751136 Interface expansion module } Fig.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Timing diagram a b b Legend } POWER: Supply voltage } Button 1/Button 2: Input circuits } Feedback loop: Feedback loop } Output safe: Safety outputs } Output aux: Auxiliary contacts } Out semi: Semiconductor output switch status } t0: Recovery time after power on } t1: Simultaneity, channel 1 and 2 } t2: Delay-on de-energisation } a: Operating cycle ended through button 1 or 2 } b: S34-S12 must be closed before before the
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Installation Install base unit without contact expansion module: } Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and PNOZsigma contact expansion module: } Remove the plug terminator at the side of the base unit and at the contact expansion module. } Connect the base unit and the contact expansion module to the supplied connector before mounting the units to the DIN rail.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Preparing for operation Supply voltage Unit types with UB 48-240 VAC/DC S22 Input circuit Unit types with UB 240 VDC A1 L A1 L+ A2 N A2 L- Single-channel Dual-channel Two-hand button S1 S11 with detection of shorts across contacts S21 S2 S12(+) S22(-) Feedback loop with feedback loop monit- without feedback loop oring monitoring Link or contacts from external contactors S12 S34 13 (23,33) 14 (24,34) K5 K6 L1 K5 N K6 S
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Dimensions in mm *with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Electrical data 750106 750136 1A 1A Max. conductor cross section Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Relay outputs 750106 750136 160 A²s 10 A 6A 6A 66 A²s 6A 4A 6A 6A AgCuNi + 0,2 µm Au 4A AgCuNi + 0,2 µm Au 750106 750136 – 6A – 6A – 4,5 A 6A 6A 6A 6A 6A 4,5 A Times 750106 750136 Delay-on de-energisation (response time in accordance with EN 574) Normally open contact N/C Recovery time Supply interruption before de-energisation Simultaneity, channel 1 and 2 max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Environmental data 750106 750136 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61000-6-4, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Mechanical data 750106 750136 Dimensions Height Width Depth Weight 98 mm 22,5 mm 120 mm 185 g 98 mm 22,5 mm 120 mm 205 g Where standards are undated, the 2014-07 latest editions shall apply. Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Inputs 751106 751136 24 V 24 V 24 V 24 V 15 mA 15 mA Semiconductor outputs 751106 751136 Number Voltage Current 1 24 V 20 mA 1 24 V 20 mA Relay outputs 751106 751136 3 1 1 kA 3 1 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W EN 60947-5-1 EN 60947-5-1 Voltage
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Relay outputs Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Conventional thermal current while loading several contacts 751106 751136 – 6A – 6A – 4,5 A 6A 6A 6A 6A 6A 4,5 A Times 751106 751136 Delay-on de-energisation (response time in accordance with EN 574) Normally open contact N/C Recovery time Supply interruption before de-energisation Simultaneity, channel 1 and 2 max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Environmental data 751106 751136 EN 60947-1 III / II 2 250 V 4 kV EN 60947-1 III / II 2 250 V 4 kV IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 751106 751136 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded termina
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Safety characteristic data Operating Mode Two-hand function EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,62E-09 SIL 3 3,32E-05 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Service life graph The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Unit types with UB 240 VDC UB: 24 VDC; Order no. 750106, 751106 Cycles x 1000 } Switching current (A) Fig.: Service life graphs at 24 VDC and 230 VAC Pilz GmbH & Co.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s6 Switching current (A) Fig.: Service life graphs at 110 VDC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 667]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Unit types with UB 48 – 240 VAC/DC UB: 48 – 240 VAC/DC; Order no. 750136, 751136 Cycles x 1000 } Switching current (A) Number of cycles x 1000 Fig.: Service life graphs at 24 VDC and 230 VAC Switching current (A) Fig.: Service life graphs at 110 VDC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s6 Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 667]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts. With capacitive loads, any power surges that occur must be noted.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 PNOZ s6.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Block diagram/terminal configuration Unit types with UB 24 VDC UB: 24 VDC; Order no. 750126, 751126 Interface expansion module } Fig.: Centre: Front view with cover, right: Front view without cover *Insulation between the non-marked area and the relay contacts: Basic insulation (overvoltage category III), Protective separation (overvoltage category II) Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Unit types with UB 48 - 240 VAC/DC UB: 48 - 240 VAC/DC; Order no. 750156, 751156 Interface expansion module } Fig.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Installation Install base unit without contact expansion module: } Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and PNOZsigma contact expansion module: } Remove the plug terminator at the side of the base unit and at the contact expansion module. } Connect the base unit and the contact expansion module to the supplied connector before mounting the units to the DIN rail.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Dimensions in mm *with spring-loaded terminals Technical details Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Electrical data 750126 External unit fuse protection F1 max. Max. conductor cross section Two-hand control relay type In accordance with the standard EN 574 Type III A 750156 Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Relay outputs 750126 750156 160 A²s 10 A 6A 6A 66 A²s 6A 4A 6A 6A AgCuNi + 0,2 µm Au 4A AgCuNi + 0,2 µm Au 750126 750156 – 6A – 6A – 4,5 A 6A 6A 6A 6A 6A 4,5 A Times 750126 750156 Delay-on de-energisation (response time in accordance with EN 574) Normally open contact N/C Recovery time Supply interruption before de-energisation Simultaneity, channel 1 and 2 max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Environmental data 750126 750156 93 % r. h. at 40 °C Not permitted EN 60947-5-1, EN 61000-6-2, EN 61000-6-4, EN 61326-3-1 93 % r. h.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Mechanical data 750126 750156 Dimensions Height Width Depth Weight 98 mm 22,5 mm 120 mm 185 g 98 mm 22,5 mm 120 mm 205 g Where standards are undated, the 2014-07 latest editions shall apply. Order no.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Relay outputs Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Conventional thermal current while loading several contacts 751126 Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact 6A Conv. therm. current with 2 con6A tacts Conv. therm.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Environmental data 751126 751156 Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Safety characteristic data Operating Mode E-STOP/ safety gate function Two-hand function EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 PL Category PL e Cat. 4 SIL CL 3 2,62E-09 SIL 3 3,32E-05 20 PL c Cat.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Service life graph The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Unit types with UB 240 VDC UB: 24 VDC; Order no. 750126, 751126 Cycles x 1000 } Switching current (A) Fig.: Service life graphs at 24 VDC and 230 VAC Pilz GmbH & Co.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s6.1 Switching current (A) Fig.: Service life graphs at 110 VDC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 688]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Unit types with UB 48 – 240 VAC/DC UB: 48 – 240 VAC/DC; Order no. 750156, 751156 Cycles x 1000 } Switching current (A) Number of cycles x 1000 Fig.: Service life graphs at 24 VDC and 230 VAC Switching current (A) Fig.: Service life graphs at 110 VDC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s6.1 Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 688]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all relay contacts. With capacitive loads, any power surges that occur must be noted.
Relays for functional safety Safety relays PNOZsigma PNOZ s7 PNOZ s7 Unit features } } Positive-guided relay outputs: – 4 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous LED for: – Input status, channel 1 – Input status, channel 2 – Switch status of the safety contacts – Fault } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Block diagram/terminal configuration Fig.: Centre: Front view with cover, right: Front view without cover *Safe separation from non-marked area in accordance with EN 60947-1, 6 kV, basic insulation between all safety contacts. Function description with PNOZsigma base unit: } Dual-channel operation via PNOZsigma connector without PNOZsigma base unit: } Single-channel operation: one input circuit affects the output relays Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Timing diagram POWER/Input Output safe Output aux. Legend } POWER/Input: Supply voltage/input circuit } Output safe: Safety contacts } Output aux.: Auxiliary contacts } t1: Switch-on delay } t2: Delay-on de-energisation Installation Install contact expansion module without base unit: } Ensure that the plug terminator is inserted at the side of the unit.
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24, 33-34, 43-44 are safety contacts; outputs 51 -52 are auxiliary contacts (e.g. for display). } Auxiliary contact 51-52 should not be used for safety circuits! } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 708]). } Calculation of the max.
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Feedback loop Base unit: Safety relay PNOZ X Base unit: Safety relay PNOZelog The inputs that evaluate the feedback loop will depend on the base unit and application 24 V DC feedback loop 51 PNOZsigma 52 expansion module 51 feedback loop Connection to PNOZsigma base unit/PNOZmulti Mini base Base unit: Safety relay PNOZunit sigma 52 PNOZsigma expansion module Base unit: Small control system PNOZmulti Mini The feedback loop is connected a
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Technical details General 750107 751107 751187 Approvals CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed Electrical data 750107 751107 751187 24 V DC -20 %/+20 % 24 V DC -20 %/+20 % 24 V DC -20 %/+20 % 2W 20 % 100 % 2W 20 % 100 % 2W 20 % 100 % Inputs 750107 751107 751187 Number Voltage at Input circuit DC Current at Input ci
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Relay outputs 750107 751107 751187 EN 60947-5-1 260 A²s 10 A 6A 10 A EN 60947-5-1 260 A²s 10 A 6A 10 A EN 60947-5-1 260 A²s 10 A 6A 10 A 6A 6A 6A 160 A²s 4A 2A 4A 160 A²s 4A 2A 4A 160 A²s 4A 2A 4A 2A AgCuNi + 0,2 µm Au 2A AgCuNi + 0,2 µm Au 2A AgCuNi + 0,2 µm Au 750107 751107 751187 6A 6A 6A 5,5 A 5,5 A 5,5 A 4,5 A 4,5 A 4,5 A 4A 4A 4A Times 750107 751107 751187 Switch-on delay With automatic start after power o
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Times 750107 751107 751187 Delay-on de-energisation With E-STOP typ. With E-STOP max. With power failure typ. With power failure max.
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Mechanical data Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spr
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZsigma PNOZ s7 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s7 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 708]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 PNOZ s7.1 Unit features } Relay outputs: – 3 safety contacts (N/O), instantaneous } Supply voltage for expansion modules } LED for: – Supply voltage at B1 and B2 – Input status, channel 1 – Input status, channel 2 – Switch status of the safety contacts – Fault } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Block diagram/terminal configuration Fig.: Centre: Front view with cover, right: Front view without cover *Safe separation from non-marked area in accordance with EN 60947-1, 6 kV, basic insulation between all safety contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Timing diagram POWER/Input Output safe Feedback Legend } POWER/Input: Supply voltage/Input } Output safe: Safety contacts } Feedback: Feedback loop } t1: Switch-on delay } t2: Delay-on de-energisation Installation Install contact expansion module without base unit: } Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and contact expansion module PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Please note the max. power consumption of the contact expansion modules (see technical data PNOZ s7.1). Expansion options : Base unit : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7.2 with terminator : Base unit : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Expansion module PNOZ s7, s8, s9, s10, s11 as a terminator : Contact expansion module PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Please note the max. power consumption of the contact expansion modules (see technical data PNOZ s7.1). Expansion options : Contact expansion module PNOZ s7.1 with terminator : Contact expansion module PNOZ s7.2 : Expansion module PNOZ s7, s8, s9, s10, s11 as a terminator : Base unit : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 } Ensure the wiring and EMC requirements of IEC 60204-1 are met. } The power supply must comply with the regulations for extra low voltages with protective electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Technical details General 750167 751167 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 750167 751167 24 V DC -20 %/+20 % 24 V DC -20 %/+20 % 2W 20 % 100 % 2W 20 % 100 % 20 W 20 W Inputs 750167 751167 Number Voltage at Input circuit DC Current at Input circuit DC Max. inrush current impulse Current pulse, input circuit Pulse duration, input circuit Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Conventional thermal current while loading several contacts 750167 Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact 6A Conv. therm. current with 2 con5,5 A tacts Conv. therm.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Environmental data 750167 751167 Rated impulse withstand voltage Protection type Mounting area (e.g.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.1 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s7.1 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 723]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 PNOZ s7.2 Unit features } Positive-guided relay outputs: – 4 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } Connection option for expansion modules } LED for: – Input status, channel 1 – Input status, channel 2 – Switch status of the safety contacts } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 Block diagram/terminal configuration Fig.: Centre: Front view with cover, right: Front view without cover *Safe separation from non-marked area in accordance with EN 60947-1, 6 kV, basic insulation between all safety contacts. Function description with PNOZsigma s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 Please note the max. power consumption of the contact expansion modules (see technical data PNOZ s7.1). Expansion options : Base unit : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7.2 with terminator : Base unit : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Expansion module PNOZ s7, s8, s9, s10, s11 as a terminator : Contact expansion module PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 Please note the max. power consumption of the contact expansion modules (see technical data PNOZ s7.1). Expansion options : Contact expansion module PNOZ s7.1 with terminator : Contact expansion module PNOZ s7.2 : Expansion module PNOZ s7, s8, s9, s10, s11 as a terminator : Base unit : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 Preparing for operation AC DC Contact expansion module PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 Technical details General 750177 751177 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 750177 751177 Supply voltage Voltage Kind Power consumption Duty cycle 24 V DC 2W 100 % 24 V DC 2W 100 % Inputs 750177 751177 Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 Mechanical data 750177 751177 Dimensions Height Width Depth Weight 98 mm 17,5 mm 120 mm 170 g 100 mm 17,5 mm 120 mm 170 g Where standards are undated, the 2014-07 latest editions shall apply. Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Cat.
Relays for functional safety Safety relays PNOZsigma PNOZ s7.2 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s7.2 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 735]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 PNOZ s8 Unit features } Relay outputs: – 2 safety contacts (N/O), instantaneous } 1 semiconductor output } LED for: – Input status, channel 1 – Input status, channel 2 – Switch status of the safety contacts – Fault } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Interface expansion module Block diagram/terminal configuration Fig.: Centre: Front view with cover, right: Front view without cover *Safe separation from non-marked area in accordance with EN 60947-1, 6 kV, basic insulation between all safety contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Timing diagram POWER/Input Legend } POWER/Input: Supply voltage/input } Output safe: Safety contacts } Out semi: Semiconductor output } t1: Switch-on delay } t2: Delay-on de-energisation Installation Install contact expansion module without base unit: } Ensure that the plug terminator is inserted at the side of the unit.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14 and 23-24 are safety contacts, the semiconductor output Y32 is an auxiliary output (e.g. for display). } Semiconductor output Y32 should not be used for safety circuits! } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 747]). } Calculation of the max.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Feedback loop } with PNOZsigma base unit: The feedback loop is connected and evaluated via the connector. } without PNOZsigma base unit: Feedback loop does not need to be monitored because the contact expansion block monitors its own output contacts. Semiconductor output *Connect together the 0V connections on all the external power supplies Dimensions in mm 120 (4.72") *with spring-loaded terminals 98 (3.86") 12,5 (0.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Technical details General 750108 751108 Approvals CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed Electrical data 750108 751108 24 V DC -20 %/+20 % 24 V DC -20 %/+20 % 2W 20 % 100 % 2W 20 % 100 % Inputs 750108 751108 Number Voltage at Input circuit DC Current at Input circuit DC Max. inrush current impulse Current pulse, input circuit Pulse duration, input circuit Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Relay outputs 750108 751108 240 V 0,02 A 3A 720 VA 24 V 0,02 A 3A 72 W 240 V 0,02 A 3A 720 VA 24 V 0,02 A 3A 72 W EN 60947-5-1 EN 60947-5-1 230 V 1,5 A 24 V 1,5 A 230 V 1,5 A 24 V 1,5 A 240 V AC G. P. 3A 24 V DC G. P. 3A B300, R300 240 V AC G. P. 3A 24 V DC G. P. 3A B300, R300 EN 60947-5-1 4A 2A 4A EN 60947-5-1 4A 2A 4A 2A 3A AgSnO2 2A 3A AgSnO2 750108 751108 Switch-on delay With automatic start after power 100 ms on typ.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Times 750108 751108 Delay-on de-energisation With E-STOP typ. With E-STOP max. With power failure typ. With power failure max.
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Mechanical data Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Str
Relays for functional safety Safety relays PNOZsigma PNOZ s8 Supplementary data The PFH value depends on the switching frequency and the load on the relay output. If the values in the service life table are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 PNOZ s9 Unit features } Positive-guided relay outputs, either instantaneous, delay-on de-energisation (also retriggerable), pulsing or delay-on energisation: – 3 safety contacts – 1 auxiliary contact } Switch-on time, pulse time or delay-on de-energisation selectable with rotary switches } LED indicator for: – Supply voltage – Input status, channel 1 – Input status, channel 2 – Switch status channel 1/2 – Start circuit – Error
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Block diagram/terminal configuration Fig.: Centre: Front view with cover, right: Front view without cover *Safe separation from non-marked area in accordance with EN 60947-1, 6 kV, basic insulation between all safety contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 } Delay-on energisation The set delay time is started when supply voltage is applied, the feedback loop is closed and finally the input circuit is closed. If the input circuit and feedback loop are closed once the delay time has elapsed, the safety contacts will close and the auxiliary contact will be opened. If the input circuit is opened for more than 10 ms, the safety contacts will open immediately and the auxiliary contact will be closed.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Delay-on de-energisation, retriggerable [1] [2] POWER Input Reset Output safe Output aux.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Pulse on switching on [1] [2] [3] [4] POWER t < 10 ms Input Reset Output safe Output aux.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Delay-on energisation [1] [2] [3] [4] POWER Input Reset Output safe Output aux.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 } Push the unit upwards or downwards before lifting it from the DIN rail. Wiring Please note: } Information given in the "Technical details [ } Outputs 17-18, 27-28, 37-38 are safety contacts; output 45-46 is an auxiliary contact (e.g. for display). } Auxiliary contact 45-46 should not be used for safety circuits! } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 761]).
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Set delay time Time selector switch "t[s]" Factor selector switch "n" n x t[s] = Delay time Example: t = 4 s, n = 5 Delay time = 5 x 4 = 20 s Connection } Supply voltage Supply voltage } AC DC A1 L+ A2 L- 1-channel input circuit/feedback loop Input circuit Input circuit Feedback loop S3 Without base unit (standalone) S32 PNOZs9 0V 24 V DC PNOZs9 PNOZ X feedback loop S32 S34 0V 24 V DC 24 V DC Output A1 PNOZs9 PNOZelog S
Relays for functional safety Safety relays PNOZsigma PNOZ s9 2-channel input circuit Base unit: Safety relays PNOZ s3, PNOZ s4, PNOZ s5 S34 PNOZ s3 PNOZ s4 PNOZ s5 A1 S34 PNOZ s1 PNOZ s2 Base unit: Two-hand control device PNOZ s6 The input circuit is connected and evaluated via the connector. S12 } S34 PNOZ s9 Base unit: Two-hand control device PNOZ s6.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Technical details General 750109 751109 751189 Approvals CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed CCC, CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed Electrical data 750109 751109 751189 24 V DC -20 %/+20 % 24 V DC -20 %/+20 % 24 V DC -20 %/+20 % 2W 20 % 100 % 2W 20 % 100 % 2W 20 % 100 % 0,7 A 10 ms 0,7 A 10 ms 0,7 A 10 ms 30 Ohm 20 Ohm 30 Ohm 20 Ohm 30 Ohm 20 Ohm 75
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Relay outputs Number of output contacts Safety contacts (N/O), delayed Auxiliary contacts (N/ C), delayed Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Relay outputs Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Times 750109 751109 751189 800 ms 0,04 s, 0,1 s, 0,2 s, 0,3 s, 0,4 s, 0,5 s, 0,6 s, 0,7 s, 0,8 s, 1 s, 1,5 s, 2 s, 2,5 s, 3 s, 3,5 s, 4 s, 5 s, 6 s, 7 s, 8 s, 10 s, 12 s, 14 s, 15 s, 16 s, 20 s, 25 s, 30 s, 35 s, 40 s, 50 s, 60 s, 70 s, 80 s, 90 s, 100 s, 120 s, 140 s, 150 s, 160 s, 180 s, 200 s, 210 s, 240 s, 300 s +/-1 % + +/-20 ms +/-1 % + +/-20 ms 800 ms 0,04 s, 0,1 s, 0,2 s, 0,3 s, 0,4 s, 0,5 s, 0,6 s, 0,7 s, 0,8 s, 1 s, 1,5 s, 2 s, 2,5
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Environmental data 750109 751109 751189 EN 60947-1 III 2 250 V EN 60947-1 III 2 250 V EN 60947-1 III 2 250 V 6 kV 6 kV 6 kV IP54 IP40 IP 20 IP54 IP40 IP 20 IP54 IP40 IP 20 Mechanical data 750109 751109 751189 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible Any 10,000,000 cycles Any 10,000,000 cycles Any 10,000,000 cycles PC
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Mechanical data Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 750109 751109 751189 – 9 mm 9 mm 98 mm 17,5 mm 120 mm 175 g 100 mm 17,5 mm 120 mm 175 g 100 mm 17,5 mm 120 mm 175 g Where standards are undated, the 2014-07 latest editions shall apply. Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, PL e delayed Cat.
Relays for functional safety Safety relays PNOZsigma PNOZ s9 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s9 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 761]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 PNOZ s10 Unit features } } Positive-guided relay outputs: – 4 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous LED for: – Input status, channel 1 – Input status, channel 2 – Switch status of the safety contacts – Fault } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Block diagram/terminal configuration *Safe separation from no
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Function description with PNOZsigma base unit: } Dual-channel operation via PNOZsigma connector without PNOZsigma base unit: } Single-channel operation: one input circuit affects the output relays Timing diagram POWER/Input Output safe Output aux. Legend } POWER/Input: Supply voltage/input circuit } Output safe: Safety contacts } Output aux.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24, 33-34, 43-44 are safety contacts; outputs 51 -52 are auxiliary contacts (e.g. for display). } Auxiliary contact 51-52 should not be used for safety circuits! } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 773]). } Calculation of the max.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Preparing for operation Supply voltage AC DC 24 V DC A1 PNOZsigma expansion A2 module 0V Input circuit Single-channel Base unit: Safety relay PNOZ X 24 V DC Dual-channel A1 PNOZsigma expansion A2 module 0V Base unit: Safety relay PNOZelog Driven via semiconductor outputs (24 VDC) O1 A1 PNOZsigma expansion module 0V A2 L- Feedback loop The inputs that evaluate the feedback loop will depend on the base unit and application Base uni
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Dimensions in mm 120 (4.72") *with spring-loaded terminals 98 (3.86") 45 (1.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Inputs 750110 751110 Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Relay outputs Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Times 750110 751110 30 ms 30 ms 50 ms 50 ms 20 ms 30 ms 20 ms 30 ms 20 ms 30 ms 20 ms 30 ms Environmental data 750110 751110 Climatic suitability Ambient temperature Temperature range Storage temperature Temperature range Climatic suitability Humidity Condensation during operation EMC EN 60068-2-78 EN 60068-2-78 -10 - 55 °C -10 - 55 °C -40 - 85 °C -40 - 85 °C 93 % r. h.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Mechanical data Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Sp
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 All the units used within a safety function must be considered when calculating the safety characteristic data.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Service life graph Cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Fig.: Service life graphs at 24 V DC and 230 V AC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s10 Number of cycles x 1000 10000 DC 1: 110 V DC 13: 110 V 1000 100 10 0,1 0,5 1 2 3 4 5 6 7 8 910 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 2 A } Utilisation category: AC15 } Contact service life: 300 000 cycles Provided the application to be implemented requires fewer than 300 000 cycles, the PFH value (see Technical details) can be used in the calculation.
Relays for functional safety Safety relays PNOZsigma PNOZ s11 PNOZ s11 Unit features } } Positive-guided relay outputs: – 8 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous LED for: – Input status, channel 1 – Input status, channel 2 – Switch status of the safety contacts – Fault } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Block diagram/terminal configuration *Safe separation from no
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Function description with PNOZsigma base unit: } Dual-channel operation via PNOZsigma connector without PNOZsigma base unit: } Single-channel operation: one input circuit affects the output relays Timing diagram POWER/Input Output safe Output aux. Legend } POWER/Input: Supply voltage/input circuit } Output safe: Safety contacts } Output aux.
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24, 33-34, 43-44, 63-64, 73-74, 83-84, 93-94 are safety contacts; output 51-52 is an auxiliary contact (e.g. for display). } Auxiliary contact 51-52 should not be used for safety circuits! } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 785]). } Calculation of the max.
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Feedback loop Base unit: Safety relay PNOZ X Base unit: Safety relay PNOZelog The inputs that evaluate the feedback loop will depend on the base unit and application 24 V DC feedback loop 51 PNOZsigma 52 expansion module Connection to PNOZsigma base unit/PNOZmulti Mini base Base unit: Safety relay PNOZunit sigma The feedback loop is connected and evaluated via the connector 51 feedback loop 52 PNOZsigma expansion module Base unit: Small
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Technical details General 750111 751111 Approvals CCC, CE, EAC (Eurasian), TÜV, cULus Listed CCC, CE, EAC (Eurasian), TÜV, cULus Listed Electrical data 750111 751111 24 V DC -20 %/+20 % 24 V DC -20 %/+20 % 3W 20 % 100 % 3W 20 % 100 % Inputs 750111 751111 Number Voltage at Input circuit DC Current at Input circuit DC Max. inrush current impulse Current pulse, input circuit Pulse duration, input circuit Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Relay outputs Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Relay outputs External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Times 750111 751111 Delay-on de-energisation With E-STOP typ. With E-STOP max. With power failure typ. With power failure max.
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Mechanical data Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection St
Relays for functional safety Safety relays PNOZsigma PNOZ s11 Supplementary data The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components.
Relays for functional safety Cycles x 1000 Safety relays PNOZsigma PNOZ s11 Switching current (A) Fig.: Service life graphs at 110 V DC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 2 000 000 cycles Provided the application to be implemented requires fewer than 2 000 000 cycles, the PFH value (see Technical details [ 785]) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts.
Relays for functional safety Safety relays PNOZsigma PNOZ s20 PNOZ s20 Unit features } Semiconductor outputs: – 2 safety outputs instantaneous – 1 auxiliary output instantaneous } Connection option for expansion modules } LED display for: – Supply voltage – Switch state of safety outputs – Input state channel 1/2 – Fault } Plug-in connection terminals (either spring-loaded terminal or screw terminal) } See order reference for unit types Block diagram/terminal configuration X3 X3 A1
Relays for functional safety Safety relays PNOZsigma PNOZ s20 Function description The contact expansion module PNOZ s20 also provides safety outputs. It is driven by a base unit PNOZsigma. Several PNOZ s20 units can be connected to the base unit (see Installation [ 793]). Functional procedure after supply voltage has been applied and the base unit's safety contacts are closed: } There is a high signal at safety outputs 14 and 24 and auxiliary output Y32. } LEDs "IN1", "IN2" and "Out" are lit.
Relays for functional safety Safety relays PNOZsigma PNOZ s20 Expansion options Consider the max. power consumption of all the units used in the application [2]: Up to 5 contact expansion modules PNOZ s20 (final block with terminator) PNOZsigma expansion module s20 PNOZsigma base unit PNOZsigma expansion module s20 [1]: Base unit PNOZ s3/s4/s4.1/s5/s6/s6.1 [1] [2] [2] [1] Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s20 [3]: Contact expansion module PNOZ s7.1 [4]*: Up to 10 contact expansion modules PNOZ s20 (final block with terminator) [1] [2] [3] PNOZsigma expansion module s7.2 PNOZsigma expansion module s7.2 [4] [3] PNOZsigma expansion module s20 [2]: One contact expansion module PNOZ s7.1 and up to 9 contact expansion modules PNOZ s7.2 PNOZsigma expansion module s7.
Relays for functional safety Safety relays PNOZsigma PNOZ s20 Wiring Please note: } Information given in the "Technical details [ } Outputs 14-24 are safety outputs; semiconductor output Y32 is an auxiliary output (e.g. for display). } Use copper wire that can withstand 60/75 °C. } Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. } Ensure the wiring and EMC requirements of IEC 60204-1 are met.
Relays for functional safety Safety relays PNOZsigma PNOZ s20 Dimensions in mm 120 (4.72") * with spring-loaded terminals 98 (3.86") * 100 (3,94") 22,5 (0.
Relays for functional safety Safety relays PNOZsigma PNOZ s20 Semiconductor outputs 750160 751160 Max. internal voltage drop Max. duration of off time during self test Switching capability, 2 safety outputs under load Current Power Switching capability, 1 safety output under load Current Power Switching capability auxiliary outputs Current Power Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s20 Environmental data 750160 751160 EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60068-2-6 10 - 55 Hz 0,35 mm EN 60947-1 III 2 30 V 0,8 kV EN 60947-1 III 2 30 V 0,8 kV IP54 IP40 IP20 IP54 IP40 IP20 Mechanical data 750160 751160 Mounting position Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2
Relays for functional safety Safety relays PNOZsigma PNOZ s20 Mechanical data 750160 751160 Dimensions Height Width Depth Weight 98 mm 22,5 mm 120 mm 120 g 100 mm 22,5 mm 120 mm 120 g Where standards are undated, the 2014-06 latest editions shall apply. Safety characteristic data Operating Mode 1-channel 2-channel EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category PL d PL e Cat. 2 Cat.
Relays for functional safety Safety relays PNOZsigma PNOZ s22 PNOZ s22 Unit features } Positive-guided relay outputs: – 6 safety contacts (N/O), instantaneous – 2 auxiliary contacts (N/C), instantaneous } 3 safety contacts and 1 auxiliary contact each; these can be controlled separately } LED indicator for: – Input state of channel Ext.1/O0 – Input state of channel Ext.
Relays for functional safety Safety relays PNOZsigma PNOZ s22 Function description } Dual-channel operation and supply voltage via PNOZsigma connector } 3 safety contacts and 1 auxiliary contact each; these can be controlled separately Installation Connect the contact expansion block to the PNOZ s30 or base unit PNOZ mm0.1p/ PNOZ mm0.2p } Connect the contact expansion block using the connector supplied.
Relays for functional safety Safety relays PNOZsigma PNOZ s22 Preparing for operation Connection Supply voltage/input circuit/feedback loop Connection to speed monitor PNOZ s30/PNOZmulti Mini base unit DC PNOZ s30/ PNOZ mm0.1p PNOZ mm0.
Relays for functional safety Safety relays PNOZsigma PNOZ s22 Technical details General 750132 751132 Approvals CCC, EAC (Eurasian), TÜV, cULus Listed CCC, EAC (Eurasian), TÜV, cULus Listed Electrical data 750132 751132 -15 %/+20 % -15 %/+20 % 24 V DC 1,5 W 100 % 24 V DC 1,5 W 100 % 750132 751132 6 2 1 kA 6 2 1 kA EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A 6A 1500 VA 24 V 0,01 A 6A 150 W 240 V 0,01 A
Relays for functional safety Safety relays PNOZsigma PNOZ s22 Relay outputs Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current External contact fuse protection, safety contacts In accordance with the standard Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s22 Conventional thermal current while loading several contacts 750132 Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact 6A Conv. therm. current with 2 con5A tacts Conv. therm.
Relays for functional safety Safety relays PNOZsigma PNOZ s22 Mechanical data 750132 751132 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Conductor cross section with spring-loaded
Relays for functional safety Safety relays PNOZsigma PNOZ s22 Safety characteristic data Operating Mode EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 PL Category Safety contacts, instantaneous PL e Cat. 4 EN 62061 EN 62061 IEC 61511 IEC 61511 SIL CL PFHD [1/h] SIL PFD EN ISO 13849-1: 2015 TM [year] SIL CL 3 2,31E-09 SIL 3 2,03E-06 20 Supplementary data The PFH value depends on the switching frequency and the load on the relay output.
Relays for functional safety Number of cycles x 1000 Safety relays PNOZsigma PNOZ s22 Switching current (A) Fig.: Service life graphs at 110 VDC Example } Inductive load: 0.2 A } Utilisation category: AC15 } Contact service life: 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH value (see Technical details [ 804]) can be used in the calculation.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 PNOZ s30 Overview Unit structure Range Scope of supply: } Speed monitor PNOZ s30 } Terminator } Connection terminals } Chip card } Chip card holder } Documentation on data medium Unit features Using the product PNOZ s30: Speed monitor for safe monitoring of standstill, speed, speed range, position and direction.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 } } Positive-guided relay outputs – 2 safety contacts (NO) – 2 auxiliary contacts (NC) Semiconductor outputs – 4 auxiliary outputs } Expansion interface for 2 more safe relay outputs that be controlled separately } Can be configured via the display on the speed monitor } Configuration is stored on a chip card } Display – Current frequencies – Current position – Warning and error messages } Status and fault LEDs } Rotary e
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Front/side view IN1 IN2 GND Y13 Y12 Y11 Y10 Y30 A1 Y1 IY2 Y35 Y34 Y33 Y32 Y31 X1 X3 X1 X3 5 PNOZ s30 IN1 IN2 GND Y13 Y12 Y11 Y10 Y30 A1 Y1 IY2 Y35 Y34 Y33 Y32 Y31 PNOZ s30 X6 3 1 Power In1 In2 Rel 1 Rel 2 Fault S11 S21 S34 13 14 23 24 11 12 21 22 A2 X6 X2 A2 X4 X6 X2 4 S11 S21 S34 13 14 23 24 11 12 21 22 X4 2 Fig.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 } Y30: 0 V ext (GND for select input and semiconductor outputs) } Y31: 24 V ext (supply for semiconductor outputs) } Y1, Y2: Y1: Feedback input for Rel. 1 Y2: Feedback input for Rel. 2 } X6: RJ45 socket for connecting the encoder (tracks A, /A, B, /B, Z, /Z, S and GND). Proximity switches can be connected via RJ45 socket or connection terminals.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Block diagram ~ S34 Reset/ Start In1 In2 GND S11 S21 24 V 0 V = X6 RJ45 Initiator Input 13 11 23 21 14 12 24 22 Relay Control Interface Extended Relais A1 A2 Rel. 1 Y1 Y2 Select Inputs (SEL) Y32 Y33 Y34 Y35 24 V ext Feedback 0 V ext Power Rel.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Timing diagram for standstill/speed monitoring: v vmax (F2) Hys. F2 vmax (F2) - Hys. F2 0 t F2 t Speed range With range monitoring, the output switches off if the rotational speed (velocity, frequency) is outside the configured range. Timing diagram for speed range monitoring: v vmax (F3) Hys. F3 vmax (F3) - Hys. F3 vmax (F2) + Hys. F2 Hys. F2 vmax (F2) 0 t F2-F3 t Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Position Position monitoring is activated via a rising edge at the start input. The current position is adopted as a reference position in the middle of the position window (configured window width) and the assigned output is switched on. The output will stay switched on provided the current position is within the position window.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Direction If the direction is to be detected safely, this function must be linked to a safety contact. } If "Direct. Right" is configured, the safety output is switched on during normal operation in clockwise rotation. } If "Direct. Left" is configured, the safety output is switched on during normal operation in anti-clockwise rotation. For both directions, a tolerance can be entered for the wrong direction.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Monitoring for broken shearpins An additional proximity switch or an HTL signal from an additional rotary encoder can be connected to track Z to monitor for broken shearpins. These must both be configured as Zfrequency monitoring. Please note: Monitoring for broken shearpins does not become active until } The minimum speed has been exceeded and } The tolerance for detecting feasibility errors has elapsed.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 } Monitored start with falling edge If a monitored start with falling edge is configured, the output switches on if the speed does not reach the limit value and then a falling edge was detected at S34. Switch delay A delay time can be set for each output (see technical details). The outputs will not switch until the set time has elapsed.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Timing diagram for speed monitoring v vmax (F2) Hys. F2 vmax (F2) - Hys. F2 0 t F2 t Example: Rel. 1 Delay time (tv) Rel. 1 Delay effect: On Off On Switch-on delay Off Too short On Off Switch-off delay t Delayed (+filtered) t Reset mode monitored/ Start pulse duration Too short Too short Feedback loop t Rel. 1 t Configuration in the example: } Switch function: F2 } Assigned output: Rel.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Speed configuration The speed monitor is configured using the rotary knob on the device. Up to 16 parameter sets (P0 ... P15), each with a max. of 9 switch functions (F1 ... F9) can be configured to monitor various operating modes, for example. One of the 16 parameter sets is selected via 4 select inputs SEL1 (Y10), SEL2 (Y11), SEL4 (Y12), SEL8 (Y13). The switch functions are monitored simultaneously.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 The following outputs are assigned to the switch functions: } F1: Relay output Rel. 1 } F2: Relay output Rel. 2 } F3: Semiconductor output Out 1 For documentation and a better overview of the device settings, we recommend that you fill in this configuration overview before setting the device parameters. Select Inputs The parameter sets are selected via the 4 select inputs SEL1 (Y10), SEL2 (Y11), SEL4 (Y12), SEL8 (Y13).
Relays for functional safety Safety relays PNOZsigma PNOZ s30 "None" mode For applications up to PL e of EN ISO 13849-1 and SIL CL 3 of EN IEC 62061. The select inputs are ignored. Only the parameter set P0 is configured and used. The lowest frequency (10 mHz) is automatically set for all other parameter sets. "1 from 4" mode For applications up to PL e of EN ISO 13849-1 and SIL CL 3 of EN IEC 62061. A maximum of 4 parameter sets can be configured and used: P1, P2, P4 and P8.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Parameter set Signal states of the select inputs P7 0 1 1 1 P8 1 0 0 0 P9 1 0 0 1 P10 1 0 1 0 P11 1 0 1 1 P12 1 1 0 0 P13 1 1 0 1 P14 1 1 1 0 P15 1 1 1 1 When using the expanded parameter sets, please note: If an open circuit occurs when the select inputs are activated, the system will switch to a parameter set with a lower number (e.g. P7 -> P3 if an open circuit occurs at SEL4).
Relays for functional safety Safety relays PNOZsigma PNOZ s30 The switch function with the lower number (e.g. F2) operates as the lower range limit; the switch function with the higher number (e.g. F3) operates as the upper range limit. Both switch functions can be assigned to one or more outputs. } Position Up to 4 different position windows can be monitored: Position 1 ... Position 4.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 } Max. encoder frequency 3.5 kHz Basic configuration 2: Rotary encoder } Encoder type Rotary encoders – } Rotary encoder type configurable Switch functions – Standstill (F1) – Standstill frequency configurable in Hz – Speed (F2) – Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Chip card The set parameters, the name of the configuration, the check sum and the passwords are stored on the chip card (see section entitled "Using the chip card"). Input device types Proximity switch } The following proximity switches can be used: – pnp – npn } The proximity switches must be fitted so that at least one is always activated.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Rotary encoders } The following rotary encoders can be used: – TTL, HTL (single-ended or differential signals) – sin/cos 1 Vss – Hiperface } The rotary encoders can be connected with or without Z index (0 index) } The cable used to connect the rotary encoders must be shielded (see connection diagrams in the chapter entitled "EMC-compliant wiring").
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Output signals Output signals TTL, HTL } Single ended } Differential A U 0 /A U 0 B U 0 /B U 0 (Z) U 0 U (/Z) 0 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Output signals Sin/Cos (1 Vss) } Single ended with reference track (e.g. Hiperface ®) SIN REFSIN +0,5 V REFSIN -0,5 V REFSIN COS 2,5 V REFCOS +0,5 V REFCOS -0,5 V REFCOS } 2,5 V Differential with/without Z index (e.g. Heidenhain 1 Vss) Adapter for incremental encoders The adapter records the data between the encoder and the drive and makes it available to the PNOZ s30 via the RJ45 socket.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Installation General installation guidelines Install base unit without contact expansion module: } Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and PNOZsigma contact expansion module: } Remove the plug terminator at the side of the base unit and at the contact expander module. } Connect the base unit and the contact expander module to the supplied connector before mounting the units to the DIN rail.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Commissioning Wiring General wiring guidelines Note: } Information given in the "Technical details" must be followed. } Use copper wire that can withstand 75 °C. } The cable used to connect the encoders and proximity switches must be shielded (see connection diagrams in the chapter entitled "EMC-compliant wiring"). } The shield may only be connected to earth at a single point. } Earth loops should be avoided.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Connection of proximity switches The following proximity switch combinations can be connected: } A: pnp, B: pnp } A: npn, B: npn } A: pnp, B: npn } A: npn, B: pnp When connecting proximity switches please note: } Proximity switches can either be connected to terminals In1, In2 and GND or to tracks A and B plus GND on the RJ45 socket. } Track S should be used to monitor the supply voltage (see drawing).
Relays for functional safety Safety relays PNOZsigma PNOZ s30 npn proximity switch with resistor R = 47 kOhm RJ45 IN1 IN2 Connection of a rotary encoder Proceed as follows when connecting the encoder: } The encoder can be connected via an adapter (e.g. PNOZ msi6p) or directly to the PNOZ s30. } Use only shielded cables for all connections. Please refer to the chapter entitled "EMCcompliant wiring". } Always connect GND on the encoder to GND on the RJ45 connector.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Encoder types: } TTL Differential } HTL differential } sin/cos 1 Vss } Hiperface Encoder PNOZ s30 RJ45 Connect rotary encoder with Z index to speed monitor Encoder types: } TTL single ended Z Index } HTL single ended Z Index Please note: } Tracks /A, /B and /Z must remain free Encoder RJ45 PNOZ s30 Encoder types: } TTL differential + Z Index } HTL differential + Z Index } sin/cos 1 Vss Z Index Encoder PNOZ s30 RJ45 Pil
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Connect rotary encoder to the speed monitor via an adapter The adapter (see Accessories) is connected between the encoder and the drive. The output on the adapter is connected to the RJ45 socket on the PNOZ s30. Encoder 1 8 RJ45 PNOZ s30 Connection of proximity switch and rotary encoder When connecting the encoders and proximity switches, please refer to the chapter entitled "EMC-compliant wiring".
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Please note: Tracks /A, /B and /Z must remain free. Encoder PNOZ s30 RJ45 Sensor types: } } } } Configuration: TTL differential Z Freq. Ini pnp – TTL differential (A,/A,B,/B) + Ini pnp (Z) – TTL differential (A,/A,B,/B) + HTL differential (A as Z) – TTL differential (A,/A,B,/B) + HTL single ended (A as Z) Configuration: HTL differential Z Freq.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Please note: Track /Z must remain free!! Encoder PNOZ s30 RJ45 Reset circuit Automatic start Monitored start automatic start must only be configured No wiring necessary! Feedback circuit No feedback loop monitoring Contacts from external contactors Select inputs Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Semiconductor outputs EMC-compliant wiring EMC-compliant wiring for connecting an encoder Encoder PNOZ s30 UB RJ45 X6 To avoid EMC interference we recommend that the shield on the sensor cables or the housing of the shielded junction box is only connected to earth at a single point: A or B or C or D or E Conductor loops outside the shield must be avoided.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 EMC-compliant wiring for connecting an encoder with drive Encoder PNOZ s30 RJ45 X6 To avoid EMC interference we recommend that the shield on the sensor cables or the housing of the shielded junction box is only connected to earth at a single point: A or B or C or D or E Conductor loops outside the shield must be avoided. If a shielded junction box is not used, the shield must run continuously from the sensor to the evaluation device.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 EMC-compliant wiring for connecting 2 proximity switches PNOZ s30 IN1 RJ45 IN2 GND To avoid EMC interference we recommend that the shield on the sensor cables or the housing of the shielded junction box is only connected to earth at a single point: A or B or C or D or E Conductor loops outside the shield must be avoided. If a shielded junction box is not used, the shield must run continuously from the sensor to the evaluation device.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Display menu - Configuration The menu settings are made on the unit's display via a rotary knob. You have the option to make the settings on the knob by hand or with a screwdriver. If you make the settings with a screwdriver, the knob can remain within the unit. Create configuration overview For a better overview, before entering the configuration values we recommend that they are entered in the form PNOZ_s30_Config_Overview: Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Operate rotary knob [2] [1] Pull out knob (A): } until it locks into position } Release knob (B) and push it back into the unit: – Press the bar on the side of the knob [1] towards the centre of the knob. This releases the knob.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Password protection The configuration is protected through passwords. There is a master password and a customer password. Factory setting for both passwords: 0000 The password levels contain different authorisations: } Master password Display: All settings Edit: All settings } Customer password Display: All settings Edit: } – The customer password can be changed. – The language can be changed.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Insert chip card Make sure that you do not bend the chip card as you insert it into the chip card slot. Write data to chip card If you are inserting a chip card which has not yet been written by a PNOZ s30, you have the option to: Insert chip card Please insert SIM Card! 1. 2.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Read data from chip card If you are inserting a chip card which has not yet been written by a PNOZ s30, you have the option to: Insert chip card (data on chip card different from device) Current menu 1. SIM: Name of the configuration (8 characters) CRC: 12345 (0 .. 65535) Load SIM: No? 2. SIM: Name of the configuration (8 characters) Data is read into the device Current menu CRC: 12345 (0 ..
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Duplicate chip card You can also create copies of a chip card and its data. Proceed as follows: } Remove chip card containg the device data. } Insert a new chip card into the device. } Confirm the message Write configuration to SIM Yes?. } The new chip card is written. Save configuration with Software SmartCardCommander You have the option to save a PNOZ s30 configuration from the chip card to your computer.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 6. To read the data on the chip card, click on the Memory Card directory and then select Read Data from Card. 7. When Data read successfully is displayed on the software interface, the data can be saved as a hex file in any directory on the computer. 8. Make sure that the corresponding configuration CRC, which you noted down, is saved in the same directory. Download configuration from the computer to the PNOZ s30 1.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Basic settings Ini pnp pnp Settings for basic configuration 1 Designation Level on the display Description 1 Basic Parameter Select the default settings with which the basic configuration menu Ini pnp pnp is to be called: Ini pnp pnp Default Settings -Load : The basic parameters are loaded. Then it switches to the basic menu Ini pnp pnp. Load? The basic parameters should always be loaded when commissioning for the first time.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 } Start mode – } Rel.1 and semiconductor output Out 1, Rel.2 , Out 1, Out 2: Automatic start "Automatic" Switch delay None } Max. encoder frequency 3.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Designation Level on the display Description Settings 2 v max Enter the max. permitted speed 10 mHz to 1.00 MHz Rel.2 Out 2 Default 5.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Settings Designation Level on the display Description Settings 1 Permanent Display Permanent display Display combinations: Default Current values and information re- -vz (current speed of track Z) H : Min : Sec (system garding configuration are dis-v (current speed of track AB) played. time) - Position You can change the permanent v (current speed of display on the display track AB) - Switch functions F1...
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Designation Level on the display Description 1 Encoder Settings Create encoder configuration for the tracks A, Settings /A, B, /B, Z, /Z, S 2 Encoder Default Undefined Select pre-defined encoder types for the tracks A, B and Z: No encoder selected: - Undefined Proximity switch Encoder - with and without inverted signals - with or without Z-Index (0-Index) - with proximity switch at track Z Proximity switch (Ini): - Initiator A: pnp B
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Designation Level on the display Description Settings Rotary encoder + pnp proximity switch TTL + pnp proximity switch * - TTL diff. (A, /A, B, /B), Z Freq Inipnp (Z) - TTL single (A, B), Z Freq Inipnp (Z) HTL + pnp proximity switch * - HTL diff.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Designation Level on the display Description 3 Track /A/B For information only: Settings Information on the use of the inverted tracks /A and /B: No track /A /B or Inverted (inverted tracks /A and /B used) or Uref external (e.g.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Designation Level on the display Description Settings 3 Track Z fmax Enter max. frequency of the encoder on track Z 10 mHz … 1.00 MHz Default 10 mHz Important: The frequency must be less than the max. encoder frequency specified in the encoder's data sheet 2 fAB/fZ Ratio Default 1.0000 : 1 Enter the ratio of the frequency on 0.0001 ... 400,000 : 1 tracks AB "fAB" to the frequency on track Z "fZ".
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Designation Level on the display 1 Function Parameter Select function parameter 2 Standstill Description Select standstill frequency -v max: : Settings 10 mHz ... 1.00 MHz or the corresponding value in the selected unit Default 2.00 Hz 2 (F1 ... F9) Parameter 3 (F1 ... F9) (P0 ... P15) Enter parameter for the switch functions F1 ... F9 For each switch function F1 ... F9, 16 parameters P0 ... P15 can be configured.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Designation Level on the display Description 4 (F1 ... F9) Select left-hand or right-hand direction monitoring (P0 ... P15) Settings (Direct. Left, Direct. Right) 1 Assign Outputs Assign functions to outputs 2 Output Each output can be assigned a switch function (F1...F9) or a range (F2-F3, F4-F5, F6-F7, F8F9). Each output can also be used as an error output (error) or be switched off (Off). (Rel.1 ... Out 4) Default Off -Off -F1.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Designation Level on the display Description Settings 2 Start mode Select start mode for each output separately - Automatic ((Rel.1 ... Out 4) ) Automatic: Automatic start Default Monitored / - Monitored / -Monitored \ Monitored /: Monitored start with rising edge at S34 Monitored \: Monitored start with falling edge at S34 Advanced settings Level Menu designation Description 1 Positions Parameter Settings for position monitori
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Level Menu designation Description Settings 2 (F1 ... F9) Function Hysteresis Enter hysteresis for the switching functions F1 ... F9 0 ... 50 % Default (not effective with position and direction monitoring) 1% 1 Output Delay Setting for the delay effect and delay time for the outputs 2 Delay Output Setting for the delay time effect and delay time for the respective output (Rel.1 ...
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Level Menu designation Description 1 Password Settings Change passwords Settings Reference: In the "Default Settings" menu, the passwords are reset to the default setting: 00000. 2 Master PW Change master password 0000 ... 9999 2 Customer PW Change customer password 0000 ...
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Information Level Menu designation Description Display/Settings 1 System Time Time that the device is switched on xxx.xxx h Max. measured linear/rotational speed at tracks A and B 0 … 4.29 MHz 1 Max. Speed Track AB The value can be reset to 0 xx min xx s or the corresponding value in the set unit Reset: Reset: - Yes ? - No 1 Max. Speed Track Z Max. measured linear/rotational speed at track Z The value can be reset to 0 0 … 4.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Level Menu designation Description Display/Settings 1 Error Stack Entries Error stack entries Repairable error: Up to 20 error stack entries are displayed Level 2: 1st line: Seq. No. "Err.:", error number Repairable errors: Level 2, 3 and 4 2nd + 3rd line: Plain text to describe error for the user (can be rectified by user) System errors: Level 2 and 3 Level 3: (internal error, information for Pilz Service). 1st line: Seq. No.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Level Menu designation Description Display/Settings - Actual Errors Up to 8 errors are displayed. Repairable error: Repairable errors: Level 2, 3 and 4 Level 2: (can be rectified by user) 1st line: Seq. No. "Err.:", error number System errors: Level 2 and 3 2nd + 3rd line: Plain text to describe error for the user (internal error, information for Pilz Service). The error messages can be hidden with "Escape". Level 3: 1st line: Seq.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Level Menu designation Description - Please insert SIM Card! Appears when the device is operated without a chip card or when a defective chip card is inserted, Display/Settings appears again when parameters are changed. Info: The message disappears after 30 s or by pressing the rotary knob - Please insert writable SIM Card! Appears when the answer to "Load SIM" and "Write Configuration to SIM:" is "No" - SIM: ........
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Level Menu designation Description Display/Settings - Password: -> Enter customer password 0000 ... 9999 Default 0000 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Example: Configure basic configuration 2 Main Menu F: 123456789 v: -1.72 kHz 12345678 Imp Submenu 1 Submenu 2 Submenu 3 Submenu 4 Basic Settings Ini pnp pnp Basic Settings Encoder Password: _000 x3 Password: Password: 1_00 1000 Master Password correct Load Basic Parameter Encoder ? Input Device TTL differentiell Standstill Rel.1 Out 1 100 Hz > Standstill Rel.1 Out 1 100 Hz >Standstill Rel.1 Out 1 300 Hz Standstill Rel.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Technical details General 750330 Approvals CCC, CE, GOST, TÜV, cULus Lis- CCC, CE, GOST, TÜV, cULus Listed ted Electrical data 750330 751330 24 - 240 V AC/DC -15 %/+10 % 24 - 240 V AC/DC -15 %/+10 % 9,0 VA 9,0 VA 5,5 W 50 - 60 Hz 160 % 100 % 5,5 W 50 - 60 Hz 160 % 100 % 1,00 A 1,00 A Max. conductor cross section Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Inputs 750330 751330 24,0 V 24,0 V 24,0 V 24,0 V 5,0 mA 5,0 mA 5,0 mA 5,0 mA 0,06 A 0,06 A 0,06 A 0,06 A Semiconductor outputs 750330 751330 Number Voltage Current External supply voltage Voltage tolerance 4 24,0 V 50 mA 24,0 V -20% / +20% 4 24,0 V 50 mA 24,0 V -20% / +20% Relay outputs 750330 751330 2 2 2 2 EN 60947-4-1 EN 60947-4-1 240 V 0,01 A 4,0 A 1000 VA 24 V 0,01 A 4,0 A 100 W 240 V 0,01 A 4,0 A 1000 VA 24 V 0,01 A
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Times 750330 751330 15 ms 50 ms 15 ms 50 ms 3.920 ms 3.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Environmental data 750330 751330 EMC EN 60947-5-1, EN 61000-6-2, EN 61000-6-3 EN 60947-5-1, EN 61000-6-2, EN 61000-6-3 EN 60068-2-6 10,0 - 55,0 Hz 0,35 mm EN 60068-2-6 10,0 - 55,0 Hz 0,35 mm EN 60947-1 II 2 250 V 4,00 kV EN 60947-1 II 2 250 V 4,00 kV IP54 IP30 IP20 IP54 IP30 IP20 Mechanical data 750330 751330 Mounting position Mechanical life Material Bottom Front Top Connection type Mounting type Conductor cross section with scre
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Mechanical data Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight 750330 751330 – 9 mm 98,0 mm 45,0 mm 120,0 mm 410 g 100,0 mm 45,0 mm 120,0 mm 410 g Where standards are undated, the 2009-06 latest editions shall apply.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Supplementary data Service life graph of output relays The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Example } Inductive load: 0.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Categories Safety level The maximum achievable safety level depends on the encoder, the wiring and the operating mode of the PNOZ s30.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 The monitoring function of the PNOZ s30 can be used to implement safety functions defined in the standard EN 61800-5-2 for Adjustable speed electrical power drive systems.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Achievable safety level Safety function PL in accordance with EN ISO 13849-1: 2015 SIL CL in accordance with EN IEC 62061 Speed PL c (Cat. 1) - Speed range Direction Standstill Position Safety-related characteristic data for operation with non-safety-related rotary encoder with mechanical fault exclusion In accordance with EN 61800-5-2 : 2007, Table D.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Achievable safety level Safety function PL in accordance with EN ISO 13849-1: 2015 SIL CL in accordance with EN IEC 62061 Speed PL d (Cat.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 } Fault detection via the error variable with subsequent shutdown must meet the requirements of the safety function, with regard to reaction times for example. } The drive controller must evaluate the same incremental/sincos signals from the encoder for control as are processed by the safe evaluation device (important on encoders with combined analogue/digital interface).
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Safety-related characteristic data for operation with a safe rotary encoder Safe encoders are certified in accordance with EN 61508, EN 13849 and EN 62061. In order to achieve the safety level stated by the encoder, the safe evaluation device (PNOZ s30) must normally detect designated errors. Details of the safe encoder's requirements of the evaluation device can be found in the user documentation for the safe encoder.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Achievable safety level Safety function PL in accordance with EN ISO 13849-1: 2015 SIL CL in accordance with EN IEC 62061 Speed PL e (Cat.4) 3 Speed range Direction Standstill Position Safety-related characteristic data for operation with a safe rotary encoder with Z index Safe encoders are certified in accordance with EN 61508, EN 13849 and EN 62061.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Safety-related architecture SRP/CS Sensor SRP/CS Logic Sensor PNOZ s30 safe encoder with track Z Logic + Diagnostic SRP/CS Actuator Actuator To calculate the safety function you will need the following data for the "sensor" subsystem and "PNOZ s30" subsystem: Sensor PL SIL PNOZ s30 subsystem PFH (1/ h) See manufacturer Operating mode PFH (1/h) Monitoring 2 encoders 1,44E-09 Achievable safety level Safety function PL in accordan
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Permitted output signals: } Square output signals TTL, single ended } Square output signals TTL, differential } Square output signals HTL, single ended } Square output signals HTL, differential } Sin/Cos output signals 1Vss, reference voltage } Sin/Cos output signals 1Vss, differential Reference sensor Permitted encoder types: } Rotary non-safety-related encoders } Linear non-safety-related encoders } Inductive proximity switche
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Achievable safety level Safety function PL in accordance with EN ISO 13849-1: 2015 SIL CL in accordance with EN IEC 62061 Direction PL c (Cat. 1) - PL e (Cat.4) 3 Position Speed Speed range Standstill Please note: For the "sensor" subsystem, a minimum speed must be exceeded within forced dynamisation.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Safety-related architecture SRP/CS Sensor SRP/CS Logic Sensor PNOZ s30 proximity switch Logic + Diagnostic SRP/CS Actuator Actuator Sensor proximity switch To calculate the safety function you will need the following data for the "sensor" subsystem and "PNOZ s30" subsystem: Sensor PNOZ s30 subsystem Category MTTFd DC Operating mode 4 Manufacturerspecific 90 % Monitoring 2 encoders PFH (1/h) 1,44E-09 In a worst case scenario, t
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Examples Connection of proximity switch Features PNOZ s30 } Standstill monitoring for enabling the safety gate via Rel. 1: Standstill is detected at <= 2 Hz, the output Rel. 1 switches on and the safety gate can be released with the pushbutton S3. } Monitoring for overspeed via Rel. 2: Overspeed is detected at >= 500 Hz and the output Rel. 2 switches off. } Feedback loop monitoring for Rel.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Connection L+ LS3 pnp pnp F1 K2 K1 23 33 IN1 IN2 GND Y13 Y12 Y11 Y10 Y30 S12 S22 S34 41 A1 A1 13 Y1 Y2 Y35 Y34 Y33 Y32 Y31 PNOZ s30 PNOZ s4 S11 S21 Y32 42 A2 S11 S21 S34 13 23 21 11 A2 34 14 24 22 12 14 24 K2 K1 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Incremental encoder connection Features PNOZ s30 } Speed monitoring: Monitoring for overspeed for the operating modes "Setup" and "Automatic", which are selected with the switch S1. – The operating mode "Setup" is selected if the select input SEL1 is activated. Overspeed is detected during setup at >= 50 Hz and the output Rel. 2 switches off. – The operating mode "Automatic" is selected if the select input SEL2 is activated.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Configuration overview Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Connection L+ L- S1 L+ L- K2 K4 K1 K3 F1 IN1 IN2 GND Y13 Y12 Y11 Y10 Y30 A1 Y1 Y2 Y35 Y34 Y33 Y32 Y31 0V IN 24 V SPS PNOZ s30 A2 S11 S21 S34 13 23 21 11 14 24 22 12 K1 K2 K3 K4 Input device Drive * * The PNOZ msi adapters are available from Pilz as accessories Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Order reference Product Product type Features Terminals Order No. PNOZ s30 24 - 240 VAC/DC With screw terminals 750 330 PNOZ s30 C 24 - 240 VAC/DC With spring-loaded terminals 751 330 Accessories Product type Features Order No.
Relays for functional safety Safety relays PNOZsigma PNOZ s30 Product type Features Order No. PNOZ msi10p Adapter cable 2.5 m 773 854 PNOZ msi11p Adapter cable 1.5 m 773 855 PNOZ msi19p Connection cable, 1.5 m 773 846 PNOZ msi19p Connection cable, 2.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 PNOZ s50 Overview Unit structure Scope of supply } PWM relay PNOZ s50 } Connection terminals (spring-loaded terminals) } Chip card } Chip card holder } Documentation on data medium Unit features Using the product PNOZ s50: PWM relay for the safe activation of inductive loads, e.g. valves, mechanical holding brakes.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 – 2 single-pole standard inputs for feedback loops Potential of the semiconductor inputs connected to supply voltage A1/A2 } Supply voltage – 24 VDC for device – For power circuits, rated voltage 24 V, 48 VDC Supply voltage for device and power circuit are isolated from each other } Voltage output 24 VDC Potential connected to supply voltage A1/A2 } Can be configured via the display on the device } Configuration is stored on a chip c
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Front/side view 2 A1 A2 T0 T1 Y1 Y2 A2 O3 O4 S11 S11 S35 S36 A2 O5 A2 PNOZ s50 X1 X3 X1 X3 3 A1 A2 T0 T1 Y1 Y2 A2 O3 O4 S11 S11 S35 S36 A2 O5 A2 PNOZ s50 5 4 Run Power Out1 Out2 I/O Fault Fault 1 10 6 751500 000001 1.0 751500 000001 1.0 B1 B2 O1+ O1- Y10 Y11 Y20 Y21 O2+ O2- Y12 Y13 Y23 Y22 X4 X2 X4 X2 7 B1 B2 O1+ O1- Y10 Y11 Y20 Y21 O2+ O2- Y12 Y13 Y23 Y22 8 9 Fig.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Function description Introduction The PWM relay PNOZ s50 is used for the safety-related shutdown of inductive loads. It has two power outputs to activate two independent, inductive loads. Each power circuit is switched independently by two inputs. Two feedback loops monitor the switch status of the inductive loads. Two failsafe outputs signal the switch status of the inductive loads to the higher level safety control system.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Functions Switching the power circuits on and off (fast shutdown) The device has two safe dual-pole outputs O1+/O1- (power circuit 1) and O2+/O2-(power circuit 2), which can be switched using inputs Y10/Y11 (power circuit 1) and Y20/Y21 (power circuit 2): } } Switch-on (brake is ventilated): – O1+/O1- is switched on when there is a "1" signal (24 VDC) at Y10 and Y11.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Both poles are switched (e.g. O1+, O1-). O3 Fig.: Start-up condition for inputs Y10/Y11 After the output O1+/O1- and/or O2+/O2- is switched on, the voltage UB1B2 is available for a configurable overexcitation time Uover. Once the overexcitation time tover has elapsed, the voltage is reduced through pulse width modulation (PWM). The overexcitation time tover and the reduced voltage UAvg are configured via the display.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Switching the power circuits on and off (slow shutdown S35, S36) If the switching times are not critical, the loads at the power circuits can also be shut down slowly. A connected brake is permitted to have longer application times, for example. The brake switches with lower noise and is lower wearing. A 1/0 pulse edge at one of the slow shutdown inputs (S35 or S36) switches off the corresponding power circuit (O1+, O2+) in single-pole mode.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Y10/Y11 Y20/Y21 t Fast S35 S36 Slow t O1+/O1O2+/O2t1 t2 Fast t3 t4 Slow t Fig.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 S35, S36 Y10, Y11 Y20, Y21 01+, 02+ UB1B2 t toff ton UAvg t Tover Y1, Y2 t O4, O5 Ton Toff t Fig.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Test pulse outputs T0, T1 Feedback loops Y1 and Y2 can be assigned test pulses. The PNOZ s50 has 2 test pulse outputs, T0 and T1. Please note the fixed allocation of test pulses to the following inputs: } T0 pulses the feedback loop Y1 } T1 pulses the feedback loop Y2 The test pulse outputs T0/T1 are switched on (24 V) in } "RUN" operating status. } "I/O Fault" operating status (fault on inputs and outputs).
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Output test Outputs that are switched on are checked via regular off tests. } Test pulses for outputs that are switched on: see technical details } Outputs that are switched on are switched off for the duration of the test pulse. } The load must not switch off because of the test. } The switch-off tests cannot be turned off. Dual-pole outputs that are switched off are checked via regular on tests.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Chip card The set parameters, the device ID and the check sum for device configuration are stored on the chip card (for further information see chapter entitled "Commissioning", under "Use chip card [ 913]").
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Mounting distances Depending on the ambient temperature, with control cabinet installation it may be necessary to maintain a certain distance from the top and bottom, as well as to other heat-producing devices (see diagram). The values stated for the mounting distances are minimum specifications. Details of whether a distance needs to be maintained can be found in the section entitled "Supplementary data [ 938]".
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Commissioning Wiring General wiring guidelines Note: } Information given in the "Technical details" must be followed. } Use copper wire that can withstand 75 °C. } The wiring must be designed to achieve sufficient noise immunity and protection against noise emissions in terms of EMC. Please also refer to DIN EN 60204-1 (Electrical equipment of machines).
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Female connector X2 O1+ O1- Y10 Y11 Y20 Y21 x 2 Female connector X3 O5 O4 O3 A2 Y2 Y1 A2 A1 x 3 Terminal Description O1+ Failsafe output for power circuit 1, positive O1- Failsafe output for power circuit 1, negative Y10 Failsafe input for fast shutdown, power circuit 1 Y11 Failsafe input for fast shutdown, power circuit 1 Y20 Failsafe input for fast shutdown, power circuit 2 Y21 Failsafe input for fast shutdown, power circuit
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Female connector X4 B1 B2 O2+ O2- Y12 Y13 Y23 Y22 x 4 Terminal Description B1 Supply voltage of power circuits B2 Reference potential of the supply voltage to the power circuits O2+ Failsafe output for power circuit 2, positive O2- Failsafe output for power circuit 2, negative Y12 Reference potential for failsafe inputs for fast shutdown, power circuit 1 Y13 Reference potential for failsafe inputs for fast shutdown, power circuit
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Supply voltage for power circuits Requirements: } When selecting the power supply, please refer to the requirements stated under Technical details [ 934]. Make sure that the supply voltage for the power circuits (B1/B2) complies with the specified tolerance of +/-10 %. If the voltage is outside this tolerance, then } – the device will change to a fault condition, if the outputs are switched on.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Inputs Fast shutdown Activation via safe single-pole outputs Link Y12 – Y13 PLC Link Y22 – Y23 PNOZ s50 O1 Y10 O2 Y11 PLC: Safety control system Y12 Y13 O3 Y20 O4 Y21 Y22 Y23 Activation via safe dual-pole outputs Link Y10 – Y11 PNOZ s50 Y10 PLC Link Y20 – Y21 O1+ Y11 PLC: Safety control system O1- Y12 Y13 Y20 O2+ Y21 O2- Y22 Y23 Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Slow shutdown Activation via single-pole outputs PLC: Safety control system O3 PNOZ s50 S35 O4 S36 PLC Connect the inputs to 24 VDC if slow shutdown is not being used. S11 24 V DC S35 S11: Voltage output 24 VDC S36 Outputs Status outputs PLC: Safety control system PNOZ s50 O3 I1 O4 I2 O5 I3 PLC Feedback loop Feedback loop A N/C contact is shown in the connection diagram. A N/O contact can also be configured.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Display menu and configuration The menu settings are made on the unit's display via a rotary knob. You have the option to make the settings on the knob by hand or with a screwdriver. If you make the settings with a screwdriver, the knob can remain within the unit.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Use chip card The parameters that are set on a device are stored on the chip card. The data is stored along with a device identifier and check sum. We recommend that you always operate the unit with a chip card. When the chip card is inside the unit, } The chip card is checked to verify the device identifier, valid parameters, and ensure that the data is identical.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Save PNOZ s50 configuration on the computer 1. Make a note of the configuration's CRC in the PNOZ s50. It is shown on the display in the Information/ Configuration CRC menu. This will be needed later to check whether the correct configuration is saved on the device. 2. Remove the chip card from the PNOZ s50 and insert it into the holder for the chip card reader. 3. Start the SmartCardCommander software. 4.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 5. To ensure that the configuration has been transferred correctly, check that the CRC for the configuration in the PNOZ s50 matches the configuration CRC you noted down on the computer. Display and configuration Menu overview The following diagrams illustrate the principle structure of the configuration menu on the display. The menu consists of } Messages at cold start, if there are problems with the chip card.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Home Level 1 PNOZ s50 O1 O2 Y1 Y2 Level 2 Home Access Denied Wrong PIN No Counter 1: 2: Input Y10 Y11 S35 Edit Config Enter PIN -----Proceed Y20 Y21 S36 Yes Level 3 Home Feedback Y1 Y2 Output O1 O2 O4 O5 O3 TO/T1 Systeminfo SW . . Parameter CRC 0x Error Stack Cat. No. dddD hh:mm:ss Error Cat. No. dddD hh:mm:ss Parameter 0x MSB LSB Fig.: Menu overview of Levels 1 and 2 Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Level 3: Configuration The device is configured in Level 3. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Level 2 Level 3 Reboot to Adopt changes Are you sure? No Yes Home Level 1 Config 1/3 Load Store Reset Load Config from Card Are you sure? No Yes Store Config to Card Are you Sure? No Yes Reset Config to Default Are you sure? No Yes Input B1/B2 Input Voltage B1/B2 0 24 V Cancel Store Y1/Y2 Pulse Pulse Cancel Config 2/3 Input Feedback Output Feedback Pulsing Y1 Y2 Output O1 O2 Store Y2 Y1 Logic Timing Cancel O2 O1 T _ _ _ _ ms
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Operate menus and enter values Various navigational aids are available on the display: } Tags } Text fields Tags Display Description Returns to the previous menu Exits the configuration menu (Level 3) and switches to the home menu (Level 1) Switches from the current error in the error stack Switches to the password menu (Level 2) Text fields Text field Description Cancel or No Rejects all the changes and returns to the previous menu Pr
Relays for functional safety Safety relays PNOZsigma PNOZ s50 2 1 O1 T 1000 ms U 12 V Cancel Store 3 4 off 450 1000 1500 2150 Fig.: Changing numeric values Display menu at cold start When the device is switched on in the Power On operating state (cold start), the memory contents of the device and the chip card are read and compared. If there are any deviations, messages will appear. Overview No Chipcard detected No chip card and no chip card holder in the device.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Overview Display Memories are unequal, Copy Ext. To Int. ? Int. To Ext. ? Description Ext. To Int. – Switch to the next menu to download parameters from the chip card to the device memory Int. To Ext. – Switch to the next menu to upload parameters from the device memory to the chip card Chipcard is Invalid The parameters on the chip card are invalid. Copy from Ext. Memory and Restart? No Yes No – Return to the previous menu Copy from Int.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Status display and configuration Level 1: Status indicators Overview PNOZ s50 C Start-up display Display Description PNOZ s50 O1 O2 Y1 Y2 PNOZ s50 – Device name O1, O2 – Outputs of the power circuits O1 and O2 Y1, Y2 – Standard inputs of feedback loops 1 and 2. Counter Number of operations Systeminfo Input States of the inputs are displayed 1: Counter for output O1+/ O1- Counter 1: 2: 2: Counter for output O2+/ O2- Systeminfo SW . .
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Overview Output States of the outputs are displayed Display Output O1 O2 O4 O5 O3 TO/T1 Description O1 – Failsafe output for power circuit 1 O2 – Failsafe output for power circuit 2 O3 – Failsafe output for fault signal O4 – Failsafe output for status of power circuit 1 O5 – Failsafe output for status of power circuit 1 TO/T1 – Test pulse output 0/1 Pilz GmbH & Co.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Overview Error Stack Error messages are displayed Display Description Error Stack Cat. No. dddD hh:mm:ss Current error stack entry Cat. – Error class (hexadecimal) No. – Error number (hexadecimal) – Error text dddD hh:mm:ss – Poweron time since Power On: Days, hours, minutes, seconds Error Cat. No. dddD hh:mm:ss Error stack entries – Entry number/ number of entries (decimal) Cat.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Level 2: Password entry Overview Display PIN Description _ _ _ _ _ _ – Field for entering the password Edit Config Enter PIN -----Proceed Password entry Proceed – Confirm entry and jump to Level 3 Home – To start menu, without confirming entry You entered an incorrect password.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Function Terminal Description Parameter Value In display menu Power circuit 2 O2+/O2- Reduced voltage U 6V Output -> O2 Overexcitation time T 100 ms Output -> O2 Maximum ventilation time Ton 30 ms Feedback -> Y2 -> Maximum application time, fast shutdown Toff fast Maximum application time, slow shutdown Toff slow Logic of feedback loop 2 Logic Y2 Overview Y1 Timing -> Y2 Ton 30 ms Feedback -> Y2 -> Y1 Timing -> Y2 Tof
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Overview Display Description Load configuration from chip card Load Config from Card Download parameters from the chip card to the device Load Config from Card Are you sure? No Yes Are you sure? – Security prompt No – Do not download parameters from chip card Yes – Download parameters from chip card Save configuration to chip card Store Config to Card Download parameters from the device to the chip card Store Config to Card Are you Sure?
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Overview Y1/Y2 Pulse Activate test pulse Display Description Y1/Y2 Pulse Pulse On/Off Pulse On: Test pulse on Cancel Cancel – Exit menu without confirming the entry Store Pulse Off: Test pulse off Store – Confirm entry Please note: The test pulses can only be activated simultaneously for both feedback loops Y1 and Y2.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Overview Y1 Toff or Y2 Toff Configure max. application time for fast and slow shutdown Display Y2 Toff Y1 Toff Fast _ _ _ _ ms Slow _ _ _ _ ms Cancel Store Description Fast < 500 > ms – Max. application time for fast shutdown Slow < 500 > ms – Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Overview Counter 1 or Counter 2 Switch to menu to set the counter for the number of operations for power circuits O1+/O1- or O2+/O2- Display Description Counter 2 Counter 1 Set: Cancel Store Counter 1 – Event counter 1 - Configure number of operations for load at power circuit O1+/O1Counter 2 – Event counter 2 - Configure number of operations for load at power circuit O2+/O2######## – Old counter status Set: – Enter new counter status, e.g.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Option two: 1. Select Reboot in menu level 3. 2. Select Yes and press the rotary knob. The device is restarted and the configuration is adopted. Examples Overview This chapter provides information on how to connect the PNOZ s50 to a safety control system. The connections illustrated are independent of any specific control system.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Configuration overview The following parameters must be set in the display menu: Function Terminal Description Parameter Value In display menu Supply voltage, power circuits 1 and 2 B1/B2 Supply voltage Input Voltage 24 V Input -> Input Voltage Test pulse Y1/Y2 Test pulses on feedback loops Pulsing On Feedback -> Pulsing -> Y1/Y2 Pulse Power circuit 1 O1+/O1- Y1 Power circuit 2 O2+/O2- Y2 Reduced voltage U 12 V Output -
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Connection Safety Control Outputs O0 O1 O2 O3 O4 O5 Inputs I0 I1 I2 PNOZ s50 Y10 Y12 Y11 Y13 Y20 Y22 Y21 Y23 S11 S35 S36 O3 Y2 O4 Y1 O5 A1 T0 A2 T1 F1 24 V DC F2 24 V DC B1 B2 O1+ O1- O2+ O2- M M B1 B2 S1 S2 Fig.: Connection example: Two mechanical holding brakes Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Technical details General Approvals CE, EAC (Eurasian), TÜV, cULus Listed Electrical data Supply voltage for Voltage Kind Voltage tolerance Output of external power supply (DC) Output of external power supply (DC) at no load Residual ripple DC External unit fuse protection F1 Potential isolation Supply voltage for Voltage Kind Voltage tolerance Output of external power supply (DC) External unit fuse protection F1 Potential isolation Supply to
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Semiconductor outputs Number of positive-switching single-pole semiconductor outputs Switching capability Voltage Current Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Times Ventilation time configurable in steps Application time during fast shutdown configurable in steps Application time during slow shutdown configurable in steps Overexcitation time configurable in steps 30 ms ... 4000 ms 30 ms ... 4000 ms 30 ms ... 4000 ms 100 ms ...
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Mechanical data Mounting type Conductor cross section with spring-loaded terminals: Flexible with/without crimp connector Spring-loaded terminals: Terminal points per connection Stripping length with spring-loaded terminals Dimensions Height Width Depth Weight plug-in 0,2 - 2,5 mm², 24 - 12 AWG 2 9 mm 100 mm 45 mm 120 mm 255 g The standards current on 2013-03 apply.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Supplementary data The max. permitted load current at the power circuits O1+/O1- and O2+/O2- depends on the } Ambient temperature. } Distance between the PNOZ s50 and adjacent devices. } Number of power circuits connected (one or two). } Size of the supply voltage to the power circuits at B1/B2. Distance reAmbient temquired between perature adjacent devices Number of power circuits Max. permitted output current at UB1/B2 = 24 V Max.
Relays for functional safety Safety relays PNOZsigma PNOZ s50 Order reference Order references Module Product type Terminals Order no. PNOZ s50 C Spring-loaded termin- 751 500 als Order references Accessories Chip cards and chip card reader Product type Features Order No.
Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30 +52 55 5572 1300 Belgium, Luxembourg The Netherlands USA (toll-free) +32 9 3217575 +31 347 320477 +1 877-PILZUSA (745-9872) France Turkey +33 3 88104000 +90 216 5775552 Asia Germany United Kingdom China +49 711 3409-444 +44 1536 462203 +86 21 60880878-216 Ireland Japan +