Datasheet

Electronic monitoring relays PMDsigma
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
True power monitoring
PMD s10
NSG-D-2-422-2014-04
Gertebild
Bildunt erschrift
True power converter for single and
three-phase electrical machinery
Approvals
Zulassungen
Unit features
Gertemerkmale PMD s10_Text_1
` Relay output:
2 auxiliary changeover contacts (C/
O)
` Analogue output for current and
voltage
` Galvanic isolation of the analogue
outputs
` Measuring range set automatically
for current and voltage
Gertemerkmale
` Menu-driven parameter setting
Gertemerkmale PMD s10_Text_3
` Status indicators (LEDs) for:
Supply voltage (Power)
Switching threshold for overload
(> max)
Switching threshold for under-
load (< min)
Output 1 (Out 1)
Output 2 (Out 2)
–Fault
` Display for measured value indica-
tor, diagnostics and menu naviga-
tion
` Operating cycle counter for K1 and
K2
` Diagnostics: U
max
and I
max
` Display of operating hours and load
hours (resettable)
` Device parameters can be saved to
chip card (write)
` Device parameters can be restored
from the chip card (load)
` Suitable for use with frequency-
controlled drives
` Suitable for current transformers
Unit description
Gertebeschreibung PMD s10
The true power converter PMD s10 is
used to measure and monitor the true
power drawn and output by electrical
loads.
The PMD s10 is designed for use as a:
` True power converter for single and
three-phase electrical machines
` Trip device for underload and over-
load
Block diagram
Blockschaltbild
PMD s10
A1 A2
K1
L1 L2 L3
Y2 Y1
Power
K2
K3 W/I3
Reset
U I 0 V
K1 U/I1 24
=
Power
21
22
~
P
U
out
I
out
14
11
12
I
M1
I
M3
U
M

Summary of content (9 pages)