PNOZ X3 } Safety relays Operating Manual 20547-EN-08
Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Source code from third-party manufacturers or open source software has been used for some components. The relevant licence information is available on the Internet on the Pilz homepage.
Contents Introduction Validity of documentation Using the documentation Definition of symbols 4 4 4 4 Safety Intended use Safety regulations Safety assessment Use of qualified personnel Warranty and liability Disposal For your safety 5 5 5 5 6 6 6 6 Unit features 7 Safety features 7 Block diagram/terminal configuration 7 Function Description Operating modes Timing diagram 8 8 9 Installation 9 Wiring 10 Preparing for operation 11 Operation Status indicators 13 13 Faults – Interference 1
PNOZ X3 Introduction Validity of documentation This documentation is valid for the product PNOZ X3. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Using the documentation This document is intended for instruction. Only install and commission the product if you have read and understood this document. The document should be retained for future reference.
PNOZ X3 INFORMATION This gives advice on applications and provides information on special features. Safety Intended use The safety relay PNOZ X3 provides a safety-related interruption of a safety circuit. The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with } E-STOP pushbuttons } Safety gates and as a safety component in accordance with the Lift Directive 95/16/EC and EN 81-1.
PNOZ X3 Use of qualified personnel The products may only be assembled, installed, programmed, commissioned, operated, maintained and decommissioned by competent persons. A competent person is someone who, because of their training, experience and current professional activity, has the specialist knowledge required to test, assess and operate the work equipment, devices, systems, plant and machinery in accordance with the general standards and guidelines for safety technology.
PNOZ X3 Unit features } Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous } 1 semiconductor output } Connection options for: } } – E-STOP pushbutton – Safety gate limit switch – Start button LED display for: – Supply voltage – Switch status of the safety contacts Semiconductor output signals: – } Switch state of the safety contacts See order reference for unit types Safety features The safety relay meets the following
PNOZ X3 Function Description The safety relay PNOZ X3 provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the start circuit S13-S14 is closed. } } Input circuit is closed (e.g. E-STOP pushbutton not operated): – Safety contacts 13-14, 23-24 and 33-34 are closed, auxiliary contact 41-42 is open. The unit is active. – The LEDs "CH.1" and "CH.2" are lit.
PNOZ X3 Timing diagram [1] [2] POWER Start Input Output safe Output aux.
PNOZ X3 Wiring Please note: } Information given in the "Technical details [ } Outputs 13-14, 23-24, 33-34 are safety contacts; output 41-42 is an auxiliary contact (e.g. for display). } Auxiliary contact 41-42 should not be used for safety circuits! } Delivery condition: Link between S11-S12 (dual-channel input circuit) } To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 15]). } Calculation of the max.
PNOZ X3 Preparing for operation Supply voltage AC DC FE Input circuit Single-channel E-STOP without detection of shorts across contacts B1 L+ B2 L- Dual-channel S1 S12 S21 S11 S22 S32 S31 E-STOP with detection of shorts across contacts S1 S22 Safety gate without detection of shorts across contacts S12 S21 S11 S22 S32 S31 S11 S32 S12 S31 S21 S1 Safety gate with detection of shorts across contacts NOTICE With single-channel wiring the safety level of your machine/plant may be low
PNOZ X3 E-STOP wiring Safety gate without start-up test Start circuit Automatic start Safety gate with start-up test S33 S34 S13 S14 S33 S34 S13 S14 Monitored start S3 S33 S34 S13 S14 NOTICE In the event of an automatic start: The unit starts up automatically when the safeguard is reset, e.g. when the E-STOP pushbutton is released. Use external circuit measures to prevent an unexpected restart.
PNOZ X3 INFORMATION With automatic start, S33 and S34 must not be linked; with monitored start, S13 and S14 must not be linked. Operation NOTICE Check each safety function – after initial commissioning and after each change of the machine/ plant – for SIL CL 3/PL e at least 1x per month, for SIL CL 2/PL d at least 1x per year Follow the instructions below: – Activate the safety function and check whether all the used safety contacts open. – Prepare for operation again and start the unit.
PNOZ X3 Faults – Interference } Earth fault: The supply voltage fails and the safety contacts open. Once the cause of the respective fault has been rectified and the supply voltage is switched off for approx. 1 minute, the unit is ready for operation again. } Contact malfunctions: If the contacts have welded, reactivation will not be possible after the input circuit has opened. } LED "POWER" does not light: Short circuit or no supply voltage. 121 (4.76") Dimensions in mm 75 (2.95") 87 (3.
PNOZ X3 Technical details Order no.
PNOZ X3 Inputs Max. overall cable resistance Rlmax Single-channel at UB DC Single-channel at UB AC Dual-channel with detection of shorts across contacts at UB DC Dual-channel with detection of shorts across contacts at UB AC Semiconductor outputs Number Voltage Current External supply voltage Voltage tolerance Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Auxiliary contacts (N/C) Max.
PNOZ X3 Relay outputs Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category In accordance with the standard Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max.
PNOZ X3 Relay outputs External contact fuse protection, auxiliary contacts Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Contact material Conventional thermal current while loading several contacts Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm.
PNOZ X3 Times Recovery time at max. switching frequency 1/s After E-STOP After power failure Waiting period with a monitored start Min. start pulse duration with a monitored start Supply interruption before de-energisation Simultaneity, channel 1 and 2 max.
PNOZ X3 Mechanical data Material Bottom Front Top Connection type Mounting type Conductor cross section with screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Dimensions Height Width Depth Weight 774310 774311 774312 PPO UL 94 V0 ABS UL 94 V0 PPO UL 94 V0 Screw terminal Fixed PPO UL 94 V0 ABS UL 94 V0
PNOZ X3 Order no.
PNOZ X3 Semiconductor outputs Current External supply voltage Voltage tolerance Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Auxiliary contacts (N/C) Max. short circuit current IK Utilisation category In accordance with the standard Utilisation category of safety contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max. current Max. power Utilisation category of auxiliary contacts AC1 at Min. current Max. current Max. power DC1 at Min. current Max.
PNOZ X3 Relay outputs Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max. melting integral Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24V AC/DC, characteristic B/C External contact fuse protection, auxiliary contacts Max.
PNOZ X3 Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max. With monitored start typ. With monitored start max. Delay-on de-energisation With E-STOP typ. With E-STOP max.
PNOZ X3 Environmental data Condensation during operation EMC Vibration In accordance with the standard Frequency Amplitude Airgap creepage In accordance with the standard Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Mounting area (e.g.
PNOZ X3 Mechanical data Dimensions Height Width Depth Weight 774314 774315 774316 87 mm 45 mm 121 mm 375 g 87 mm 45 mm 121 mm 375 g 87 mm 45 mm 121 mm 375 g Where standards are undated, the 2014-07 latest editions shall apply. Order no.
PNOZ X3 Inputs Max. overall cable resistance Rlmax Single-channel at UB DC Single-channel at UB AC Dual-channel with detection of shorts across contacts at UB DC Dual-channel with detection of shorts across contacts at UB AC Semiconductor outputs Number Voltage Current External supply voltage Voltage tolerance Relay outputs Number of output contacts Safety contacts (N/O), instantaneous Auxiliary contacts (N/C) Max.
PNOZ X3 Relay outputs Utilisation category of safety contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category of auxiliary contacts AC15 at Max. current DC13 (6 cycles/min) at Max. current Utilisation category in accordance with UL Voltage With current Voltage With current Pilot Duty External contact fuse protection, safety contacts In accordance with the standard Max.
PNOZ X3 Conventional thermal current while loading several contacts Ith per contact at UB DC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 contact Conv. therm. current with 2 contacts Conv. therm. current with 3 contacts Times Switch-on delay With automatic start typ. With automatic start max. With automatic start after power on typ. With automatic start after power on max. With monitored start typ. With monitored start max. Delay-on de-energisation With E-STOP typ. With E-STOP max.
PNOZ X3 Environmental data Vibration In accordance with the standard Frequency Amplitude Airgap creepage In accordance with the standard Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Mounting area (e.g.
PNOZ X3 Safety characteristic data NOTICE You must comply with the safety-related characteristic data in order to achieve the required safety level for your plant/machine. Operating mode – EN ISO 13849-1: 2008 EN ISO 13849-1: 2008 PL PL e Category Cat.
PNOZ X3 Service life graph Number of cycles x 1000 The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Switching current (A) Example } Inductive load: 0.
PNOZ X3 EC declaration of conformity This product/these products meet the requirements of the directive 2006/42/EC for machinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/support/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str.
Technical support is available from Pilz round the clock.