Operating Manual

PIT gb RLLE y ETH
Operating Manual PIT gb RLLE y ETH
1005249-EN-01
| 11
Wiring
Please note:
} Information given in the Technical details [ 19] must be followed.
} The power supply must meet the regulations for extra low voltages with protective elec-
trical separation (SELV, PELV).
} The supply voltage must be fitted with a 4A fuse, characteristic B/C.
} Ensure the wiring and EMC requirements of EN 60204-1 are met.
} To connect the PIT gb RLLE y ETH to the evaluation devices, use a 12-pin cable with an
A-coded M12 female connector (see Order reference: Accessories [ 24]).
} To connect the PIT gb RLLE y ETH to a controller, use a 4‑pole cable with a D-coded
M12 male connector (see Order reference: Accessories [ 24]).
} Route the cables so that they are protected.
Terminal assignment connectors
NOTICE
The colour marking for the connection lead only applies for the cable that
Pilz supplies as an accessory
1
2
3
4
5
6
7
8
9
10
11
12
12-pin M12 male connector
PIN Wire colour Function
1 Brown +24 V UB
2 Blue 0 V UB
3 White E-STOP channel 1
4 Green Pushbutton 2
5 Pink E-STOP channel 2
6 Yellow LED pushbutton 2 (H2)
7 Black E-STOP channel 1
8 Grey Pushbutton 3
9 Red E-STOP channel 2
10 Purple LED pushbutton 3 (H3)
11 Grey-pink Signal output PITreader I0/
O0
12 Red-blue E-STOP signal contact