Operating Manual

PIT gb RLLE y ETH
Operating Manual PIT gb RLLE y ETH
1005249-EN-01
| 17
Operation
Display and control elements
The use and display of pushbutton 2 and pushbutton 3 depends on the application in the
connected controller.
LED display PITreader
Legend
LED on
LED flashes
Colour State Meaning
Yellow Device is starting up
or
the firmware is being updated (if the device is re-
starting after uploading a firmware update and the
firmware update is being applied, the LED flashes
yellow)
Yellow Device is in external authentication mode and as
yet no authentication has been set for the inserted
transponder key
Blue Device is ready for operation, no transponder key
has been inserted
Green Transponder key has been recognised as valid
Red Transponder key has been recognised as invalid
(permission 0 or in external authentication mode)
Red Error (e.g. hardware error, configuration error, in-
valid or uncoded transponder key, …).
Possible remedies in the event of a configuration
error, when the device is no longer accessible un-
der the set IP address:
} Try to open the web application with the default
IP address or
} Reset the device to its default settings.
Firmware update PITreader
The update for the firmware of the PITreader is described in the operating manual for the
authentication system PITreader (see Additional documents that apply [ 7]).
Reset PITreader to default setting
Procedure:
1. Switch off the supply voltage to the PIT gb RLLE y ETH.
2. Press and hold pushbutton 2.
3. Switch on the supply voltage to the PIT gb RLLE y ETH.