Instruction Manual

General
6
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland
Telefon +49 711 3409-0, Telefax +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
English
1.3.2 Overall system overview
Antrieb
Welle
SSI
SSI
Inkremental-
Interface
optische Abtastung
magnetische Abtastung
N
S
Anschlussklemme
Fig. 1: System schematic
A
Measuring channel 1, single-turn and multi-turn
Optical detection of the number of steps/revolution
Max. 8192 steps/revolution, accuracy: 13 Bit
Synchronous serial interface (SSI)
Incremental signals for position feedback
B
Measuring channel 1, multi-turn
Magnetic detection of the number of revolutions
Max. 4096 revolutions
Synchronous serial interface (SSI)
C
Measuring channel 2, single-turn and multi-turn
Magnetic detection of the number of steps/revolution
Max. 8192 steps/revolution, accuracy: 8 Bit
Synchronous serial interface (SSI)
D
Measuring channel 2, multi-turn
Magnetic detection of the number of revolutions
Max. 4096 revolutions
Synchronous serial interface (SSI)