Manual
PSEN op4F/H-A series  OPERATING MANUAL 
24 
1003067-EN-02 
The mounting positions recommended based on the length of the light curtain are stated in 
Fig. 19 and in the following table. 
Fig. 19 – Light curtain dimensions 
MODEL 
L (mm) 
L (mm) 
incl. PSEN op 
advanced 
programming 
adapter 
A (mm) 
B (mm) 
C (mm) 
PSEN op4F-A-14-030/1 
PSEN op4H-A-30-030/1 
306.3 
363.2 
86.3  110  - 
PSEN op4F-A-14-045/1 
PSEN op4H-A-30-045/1 
456.3 
513.2 
236.3  110  - 
PSEN op4F-A-14-060/1 
PSEN op4H-A-30-060/1 
606.2 
663.1 
306.2  150  - 
PSEN op4F-A-14-075/1 
PSEN op4H-A-30-075/1 
756.2 
813.1 
406.2  175  - 
PSEN op4F-A-14-090/1 
PSEN op4H-A-30-090/1 
906.1 
963.0 
506.1  200  - 
PSEN op4F-A-14-105/1 
PSEN op4H-A-30-105/1 
1056.1 
1113.0 
606.1  225  - 
PSEN op4F-A-14-120/1 
PSEN op4H-A-30-120/1 
1206 
1262.9 
966  150  453 
PSEN op4F-A-14-135/1 
PSEN op4H-A-30-135/1 
1356 
1412.9 
1066  175  503 
PSEN op4F-A-14-150/1 
PSEN op4H-A-30-150/1 
1505.9 
1562.8 
1166  200  553 
PSEN op4F-A-14-165/1 
PSEN op4H-A-30-165/1 
1655.9 
1712.8 
1266  225  603 
PSEN op4F-A-14-180/1 
PSEN op4H-A-30-180/1 
1805.8 
1862.7 
1366  250  652.9 