14
} [6]:Responserange
} [7]:Connectoronthesensor
} [8]:Limitofresponserange,positionofgatehinge
} [9]:StatusofLED
Wiring
Pleasenote:
} Informationgiveninthe"Technicaldetails"mustbefollowed.
} Themax.cablelengthl
max
intheinputcircuitiscalculatedfrom
– themax.cablecapacitanceatthesafetyoutputs(seeTechnicaldata[ 24]).
– theminimumpermittedsupplyvoltageatthesensor(19.2V).
} Thepowersupplymustmeettheregulationsforextralowvoltageswithprotectivesep
aration(SELV,PELV).
} Theinputsandoutputsofthesafetyswitchmusthaveaprotectiveseparationto
voltagesover60VDC.
INFORMATION
Onlyusesafetyrelayswitha24VDCsupplyvoltage.Safetyrelayswithuni
versalpowersupplyorinACdeviceversionshaveinternalpotentialisola
tionandarenotsuitableasevaluationdevices.
CAUTION!
Donotconnectthesignaloutputto0V!
IfthesignaloutputY32isconnectedto0V,thesafetyswitchmaybedam
agedasaresult.ConnectthesignaloutputY32toaconsumer,e.g.tothe
inputonacontrolsystem,orleavethesignaloutputunconnected.
} Thesupplyvoltagetothesafetyswitchmustbeprotectedwitha2Ato4Aquickacting
fuse.
} EnsuretheEMCrequirementsofIEC602041aremet.
} Whenconnectinginseries,makesureyoucomplywiththewiringtechnologyrequire
ments(DINEN602041)andmanipulationprotectionrequirements(ENISO14119).
Pinassignment,connectorandcable
8pinM8/M12connector