User Manual Part 1
Table Of Contents
PSENcs5.1p
OperatingManualPSENcs5.1p
1003418EN01
19
} Thesafetyswitchandactuatorshouldbeinstalledoppositeeachotherinparallel.
Makesurethattheactuatorisalignedtothemarkingonthesensorthatguaranteesthe
operatingdistancerequiredbytheplantdesign(seeOperatingdistances[ 10]).
} SafetyswitchesandactuatorsshouldonlybesecuredusingM4screwswithaflathead
(e.g.M4cheeseheadorpanheadscrews).
} Torquesetting:Notethestatedmax.torqueintheTechnicaldetails[ 24].
} Thedistancebetweentwosafetyswitchesmustbemaintained(seeTechnical
Details[ 24]).
} Ifusingangledconnectorplugs,notethedefinedangleofthecablerouting.
} WheninstallingmakesureyoucomplywiththerequirementsofENISO14119.
} Makesurethatthesafetyswitchandactuatorcannotbeusedasanendstop.
} Theactuatorshouldbeprotectedfromunauthorisedremovalandfromcontamination.
Closethemountingholesusingthesealsprovided(seediagrams).Theuseofseals
shouldberegardedasequivalenttousingpermanentfasteningsinaccordancewith
Clause7.2cofENISO14119.
[4]
[4]
[3]
[2]
[1]
[1]
[4]
[4]
[3]
[2]
[1]
[1]
Fig.:Seals
[1]:4sealsforactuators
[2]:Unusedseals
[3]:2sealsforactuators
[4]:2sealsforswitches,2sealsunused