User Manual Part 1

PSENcs5.1p
OperatingManualPSENcs5.1p
1003418EN01
24
Technicaldetails
General
Approvals CE,EAC(Eurasian),ECOLAB,FCC,IC,TÜV,UL/
cUL
Sensor'smodeofoperation Transponder
CodificationinaccordancewithISO14119 Low
BuildingclassinaccordancewithISO14119 4
ClassificationtoEN6094753 PDDB
Electricaldata
Supplyvoltage
Voltage 24,0V
Kind DC
Voltagetolerance 20%/+20%
Outputofexternalpowersupply(DC) 1,0W
Max.switchingfrequency 3Hz
Max.cablecapacitanceatthesafetyoutputs
Noload,PNOZwithrelaycontacts 40nF
PNOZmulti,PNOZelog,PSS 40nF
Max.inrushcurrentimpulse
Currentpulse,A1 0,50A
Noloadcurrent 25mA
Inputs
Number 2
Voltageatinputs 24VDC
Inputcurrentrange 1,63,0mA
Semiconductoroutputs
OSSDsafetyoutputs 2
Signaloutputs 1
Switchingcurrentperoutput 100mA
Breakingcapacityperoutput 2,4W
Residualcurrentatoutputs 400µA
VoltagedropatOSSDs 1,0V
Conditionalratedshortcircuitcurrent 100A
Lowestoperatingcurrent 0mA
UtilisationcategoryinaccordancewithEN609471 DC12
Times
Testpulseduration,safetyoutputs 150µs
Switchondelay
afterUBisapplied 1,0s
Inputstyp. 1ms
Inputsmax. 3ms
Actuatortyp. 30ms
Actuatormax. 50ms