User Manual Part 1

PSENcs5.1p
OperatingManualPSENcs5.1p
1003418EN01
26
Mechanicaldata
Operatingdistanceswhentheactuatorapproaches
squaremarking
AssuredoperatingdistanceSao 8mm
AssuredreleasedistanceSar 20mm
TypicaloperatingdistanceSo 11mm
TypicalreleasedistanceSr 14mm
Typicalhysteresis 2mm
Operatingdistanceswhentheactuatorapproaches
trianglemarking
AssuredoperatingdistanceSao 4mm
AssuredreleasedistanceSar 12mm
TypicaloperatingdistanceSo 5mm
TypicalreleasedistanceSr 8mm
Typicalhysteresis 2mm
Operatingdistanceswhentheactuatorapproaches
semicirclemarking
AssuredoperatingdistanceSao 6mm
AssuredreleasedistanceSar 19mm
TypicaloperatingdistanceSo 9mm
TypicalreleasedistanceSr 11mm
Typicalhysteresis 2mm
Min.distancebetweensafetyswitches 250mm
SensorflushinstallationinaccordancewithEN
6094752 Yes,followinstallationguidelines
Connectiontype M8,8pinmaleconnector
Material Lexan9945,PA+GF,PBT
Fixingscrewstorquesettings 1,00Nm
Dimensions
Height 26,4mm
Width 97,6mm
Depth 13,0mm
Actuatordimensions
Height 18,0mm
Width 37,0mm
Depth 13,0mm
Weightofsafetyswitch 48g
Weightofactuator 10g
Weight 58g
Wherestandardsareundated,the201409latesteditionsshallapply.