User guide
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
9-7
9.3 DIAGNOSTICS menu
9 Diagnostics and Troubleshooting
9.3.1 Diagnostic blocks and diagnostic data
Diagnos tic blocks an d diagnostic d ata9-Diagnose_Menue_DIAGNOSTICS_Diagnosebloecke
The System Data diagnostic block contains the following diagnostic da-
ta:
 Type: The type of PSENvip
 SW Version: The software version of PSENvip
 Device Data: Device data
 Configuration: Overrun
 Tool Data: Tool data
 Error Statistic: Information on the error rate
 Thresholds: Information on the optical system
 Mod Limits: Information on the optical system
 Run Statistic: Information on the optical system
 Adjust Statistic: Information on the optical system
The Error Data diagnostic block contains the following diagnostic data:
 Error stack with the last 10 entries
The Log Data diagnostic block contains the following diagnostic data:
 Log data: Log book data.
 Press the <MODE> button to access the next diagnostic block.
 Press the  keys to access the diagnostic data within a diagnostic 
block.
 Exit the DIAGNOSTICS menu using the <ESC> key.