Datasheet MICS6814

Data Sheet
Performance RED sensor
Characteristic
RED sensor
Symbol Typ Min Max Unit
Sensing resistance in air (see note 1) R
0
- 100 1500
k
Typical CO detection range FS 1 1000 ppm
Sensitivity factor (see note 2) S
60
- 1.2 50 -
Performance OX sensor
Characteristic
OX sensor
Symbol Typ Min Max Unit
Sensing resistance in air (see note 1) R
0
- 0.8 20
k
Typical NO
2
detection range FS 0.05 10 ppm
Sensitivity factor (see note 3) S
R
- 2 - -
MiCS-6814
1143 rev 8
Notes:
1. Sensing resistance in air R
0
is measured under controlled ambient conditions, i.e. synthetic air at 23
±5°C and 50 ± 10% RH for RED sensor and synthetic air at 23 ±5°C and 5% RH for OX sensor.
Sampling test.
2. Sensitivity factor is defined as Rs in air divided by Rs at 60 ppm CO. Test conditions are 23 ± 5°C and
50 ± 10% RH. Indicative values only. Sampling test.
3. Sensitivity factor is defined as Rs at 0.25 ppm NO
2
, divided by Rs in air. Test conditions are 23 ± 5°C
and 5% RH . Indicative values only. Sampling test.
4. Sensitivity factor is defined as Rs in air divided by Rs at 1 ppm of NH
3
. Test conditions are 23 ± 5°C
and 50 ± 10% RH. Indicative values only. Sampling test.
Page 2 of 5
Performance NH3 sensor
Characteristic
OX sensor
Symbol Typ Min Max Unit
Sensing resistance in air (see note 1) R
0
- 10 1500
k
Typical NH
3
detection range FS 1 300 ppm
Sensitivity factor (see note 4) S
R
- 1.5 15 -