VIII - DTXPRO-800VH SERVICE REQUIREMENTS
Routine maintenance of the DTXPRO-800VH consists of cleaning or replacing the air inlet filter.
In normal operating environments this should be done once a month or more often in dusty
environments. Cleaning should be done with a light detergent. Rinse and dry the filter carefully
before installing. Any detergent residue could damage components in the modulator. For this
reason, the first option should be to replace the filter with a new one (PTI Part Number 990202)
The following data should be recorded in the station log. This information should be compared to
previous test recordings to insure normal operations.
1. DC SUPPLY VOLTAGE
2. DC CURRENT
3. OUTPUT POWER PERCENT (%)
4. REFLECTED POWER PERCENT (%)
5. HEAT SINK TEMPERATURE IN DEGREES CELSIUS
The performance of the adaptive linear and non- linear correction performance should be
checked under normal operating conditions. This can be done remotely if the unit is connected
via Ethernet or on each visit to the site. Adaptive linear correction is normally placed in the idle
mode once the correction is complete. If so, the corrector can be placed in AUTO RUN for a
while to optimize the correction and then returned to the idle mode.