Technical Manual

PINEAPPLE TECHNOLOGY, INC.
UTX3KW-A Operating and Service Manual
P RFLD................................................................ Reads PA output power being returned from the load and
displayed as a percentage of forward power. Typical
reading would be < 5% indicated
P AURAL............................................................. Reads the AURAL POWER component as a percentage
of forward power. Typical reading would be 10%
AUX 1 & AUX 2 ................................................. not used in this conguration
REFER TO SECTION VI.H (Page 39) FOR SCHEMATICS AND PARTS LIST
E. REMOTE MONITOR AND CONTROL WITH ABS
This equipment is OPTIONAL and can be used to satisfy FCC remote control requirements.
The Remote Monitor is used to monitor the operational status of the transmitter and will allow the
operator to turn RF on or off and adjust power levels. The following items are monitored or controlled:
1. Transmitter on/off function
2. Power output level monitor and adjust
3. AC Line voltage status — With ABS you can be notied if there is a power failure at the side.
4. Various other custom options are available. Specify these at the time the transmitter is purchased
and they will be included if possible.
Remote monitoring requires a phone line connection. Information can be accessed via a PC Terminal or
via a “VOICE COMMAND LINE.” Either option is standard with this system.
The Auxiliary power unit requires a battery connection. A common car battery (12 VDC) can be used
with a charger as an ABS. This will run the Monitor and provide access to transmitter status for several
hours.
A manual for this equipment is provided by the Manufacturer and is included in the UTX3KW-A package
shipped with the transmitter. This manual is only included if this option was purchased for delivery
with the transmitter.
REFER TO INSTRUCTION MANUAL PROVIDED WITH THIS PACKAGE.
F. MODULATOR
The heart of any TV Transmitter is the MODULATOR. This equipment receives the video and audio
signals as well as any control signals needed. The base band signals are converted to RF with an output
on the desired operating channel.
Detail operation of the Modulator with schematics and parts list is provided by the equipment manufac-
turer.
REFER TO INSTRUCTION MANUAL PROVIDED WITH THIS PACKAGE.
V — THEORY OF OPERATION
Page 12