Technical Manual

PINEAPPLE TECHNOLOGY, INC.
UTX5KW-A Operating and Service Manual
Page 55
VIII — ADJUSTMENTS AND TUNING
D. PHASE MATCHED CABLES: The cables used to connect the splitter to the PA Amplier inputs and
those provided to connect the PA Ampliers to the combiner are phase matched. If a cable is damaged
and needs to be replaced, additional cables are available from Pineapple Technology, Inc. The customer
may manufacture additional cables, however the same coax type with the same connector types should
be used. The phase matching procedure listed above may be used for adjusting the lengths. Matching
should be within +/- 2 degrees.
E. ADP500/1000 WATT METER: This unit comes calibrated from the factory for the rated power level of
the transmitter. Adjustments are not recommended in the eld.