Faucet Installation
Caution:Valveispresetatthefactorytestatmaximum.Adjustas
necessary. Please see the instructions below:
12. Turn off main supply stops and relieve the pressure.Remove handle
(N) by removing hole cover (O) and loosening set screw (Q) lift off
the handle.
13. Unscrew retainer sleeve (R) and retaining nut (S) counter clock-
wise.Usetwongersraisetheredadjustmentring(T).
14. Turn adjustment ring counter clockwise to decrease the tempera-
ture setting and clockwise to increase the temperature. Replace
the adjustment ring (T).Reassemble and test until desired safe
temperature is reached. (Note: Ensure proper alignment of cartridge
with notch in valve body.)