Compatibility Chart

One unit Two units Three units Four units Five units
12
9+9
9+12
12+12
9+9 9+9+9
9+12 9+9+12
9+18 9+9+18
12+12 9+12+12
12+18 9+12+18
18+18 12+12+12
9+18 9+9+9 9+9+9+9
9+24 9+9+12 9+9+9+12
12+12 9+9+18 9+9+9+18
12+18 9+9+24 9+9+12+12
12+24 9+12+12 9+9+12+18
18+18 9+12+18 9+12+12+12
9+18+18 12+12+12+12
12+12+12
12+12+18
12+18+18
12+12+24
18+18 9+9+18 9+9+9+9 9+9+9+9+9
18+24 9+9+24 9+9+9+12 9+9+9+9+12
24+24 9+12+12 9+9+9+18 9+9+9+9+18
9+12+18 9+9+9+24 9+9+9+9+24
9+12+24 9+9+12+12 9+9+9+12+12
9+18+18 9+9+12+18 9+9+9+12+18
9+18+24 9+9+12+24 9+9+9+18+18
9+24+24 9+9+18+18 9+9+12+12+12
12+12+12 9+9+18+24 9+9+12+12+18
12+12+18 9+12+12+12 9+12+12+12+12
12+12+24 9+12+12+18 9+12+12+12+18
12+18+18 9+12+12+24 12+12+12+12+12
12+18+24 9+12+18+18
12+24+24 9+18+18+18
18+18+18 12+12+12+12
18+18+24 12+12+12+18
12+12+12+24
12+12+18+18
MULTI SPLIT SYSTEM / INDOOR UNITS COMBINATION TABLE
Multi Split System DC Inverter Outdoor
Units
Matching Indoor Unit Types Rating Combination
Combination Options
MIN. / MAX.
Loading
Limitations
Wall: 9+9+9+9
Ducted: 9+9+9+9
24,000 / 48,000
BTU/h.
TRIPLE (3)
ZONE
YN030GMFI22M3D
Wall (09-12-018), Cassette (09-12-018), Ducted
(09-12-018), Flex Mount (09-12-18), Floor
Console (12)
Wall: 9+9+9
Ducted: 9+9+9
18,000 / 36,000
BTU/h.
DUAL (2)
ZONE
YN020GMFI22M2D
Wall (09-12), Cassette (09-12), Ducted (09-12),
Floor Console (12)
Wall: 9+9
Ducted: 9+9
12,000 / 24,000
BTU/h.
Every indoor unit attached will operate at a random, self regulated capacity, based on the actual demand it measures from the zone it is serving (Between 30% to 100% of its rated capacity or OFF). Outdoor unit will also self regulate its output capacity,
based on the total demand it reads from all of the simultaneously running indoor units at any given moment.
With multi split systems, the total demand from the outdoor unit, shall seldomly exceed 67% of the total available capacity of the combined indoor unit group due to load fluctuations.
Although very seldom, if and when the total demand from the combined indoor group exceeds the rated capacity of the outdoor unit, the capacity of the each indoor unit will be annotated acordingly. For high demand heating applications, max loading
limits may need to be reduced by 10-15 % to avoid underperformance risks at some extreme conditions.
QUINT (5)
ZONE
YN050GMFI22M5D
Wall (09-12-018-024), Cassette (09-12-018-024),
Ducted (09-12-018-024), Flex Mount (09-12-18-
024), Floor Console (12)
Wall: 9+9+9+9+9
Ducted: 9+9+9+9+9
36,000 / 64,000
BTU/h.
Do not exceed two
pieces of 24,000
BTU/h
Indoor Unit
QUAD (4)
ZONE
YN040GMFI22M4D
Wall (09-12-18-24), Cassette (09-12-18-24),
Ducted (09-12-018-24), Flex Mount (09-12-18-
24), Floor Console (12)