Installation Instructions

- 16 -
PROTECH PIRAMID XL3
7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode
Sensitivity and distance settings max. can be modified:
-
Either via the code selectors on the detector
-
Or via the smartphone application
Note: In Settings mode, sensitivity and distance settings are stored in memory by the code selectors.
In Detection mode, sensitivity and distance settings are stored in memory either by the
application: last backup performed.
To find out the values of stored settings, switch the detector to “READ” mode:
1. Set the code selector to "0".
2. Turn the "Test Mode" switch to ON.
3. The detector LED(s) will blink.
Note: only the LED linked to the code selector set to 0 will blink.
Sensitivity LED
setting
Max distance
LED setting
Code selector
sensitivity setting
Max distance code
selector setting