9 PERIODIC MAINTENANCE
To guarantee performance over time, basic maintenance operations should be performed to confirm
the status of the PIR filter. If necessary, clean the filter with a soft, moist cloth.
10 MAINTENANCE
Default settings:
-
LEDs status : disable (see §8.2 for led settings)
-
Buzzer status : enable (see §8.2 for buzzer settings)
Failure
Probable
c
auses
Solutions
Permanent alarm
-
"Test Mode" switch in the
ON position.
-
Incorrect voltage (<10V)
-
The relays are disabled.
-
Turn the "Test Mode" switch to the
OFF position.
-
Check the power supply.
-
Enable relays via the application
(see §
8.2
)
No triggering of the
intrusion alarm
-
Passage beyond the
distance set on the code
selector.
-
Change the distance set on the
code selector.
Anti-masking alarm in
permanent alarm
-
The relays are disabled.
-
The anti-masking alarm is
disabled.
-
Enable relays via application
(see §8.2)
-
Enable the anti-masking alarm
(see §8.2)
Permanente tamper
alarm
-
Tamper switches are in up.
-
If the tamper is to be used in a local
connection, wire the terminals
13,14,15.
-
If the tamper is to be used in a
network connection, turn the
switches to the bottom.
The smartphone
application cannot
detect the PIRAMID
XL3.
-
The PIRAMID XL3 BLE
connection is not activated.
-
Press on the tamper switch for at
least 2 seconds, then release.
(see §8)
-
Check that the tamper switches are
towards the bottom. (see §
8
)