Model #: ___________________________ Serial #: ___________________________ Date Purchased: ____________________ Installation & Operation Manual Model SRTE Floor Model Electric Rethermalizer Built after 8/2005 L20-292, rev.
TO THE PURCHASER, OWNER AND STORE MANAGER Please review these warnings prior to posting them in a prominent location for reference. WARNING WARNING DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING Improper installation, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this appliance.
SRTE: Electric Floor Model Rethermalizer TABLE OF CONTENTS 1. INSTALLATION......................................................................................1 1.1. CHECKING YOUR NEW APPLIANCE.......................................................................................... 1 1.2. INSTALLATION CLEARANCES ................................................................................................... 2 1.3. LEG/CASTER INSTALLATION AND LEVELING .............................................
TABLE OF CONTENTS 3.2. MONTHLY PREVENTATIVE MAINTENANCE ........................................................................... 12 3.2.1. 3.3. DELIMING ............................................................................................................................. 12 ANNUAL/PERIODIC PREVENTATIVE MAINTENANCE AND INSPECTION............................ 12 3.3.1. HEATING ELEMENT ............................................................................................................
INSTALLATION SRTE: Electric Floor Model Rethermalizer 1. INSTALLATION 1.1. CHECKING YOUR NEW APPLIANCE Your new Pitco appliance has been carefully packed into one crate. Every effort has been made to ensure that it is delivered to you in perfect condition. As you unpack your new appliance, inspect each of the pieces for damage. If something is damaged, DO NOT sign the bill of lading. Contact the shipper immediately; the shipper is only responsible for 15 days after delivery.
INSTALLATION 1.2. INSTALLATION CLEARANCES The clearances shown below are for combustible and non-combustible installations and will allow for safe and proper operation of your appliance. Back Sides Counter Combustible Construction Inches (centimeters) 6.0" (15.24cm) 6.0" (15.24cm) 6.0" (15.24cm) Non Combustible Construction Inches (centimeters) 0.0" (0.0cm) 0.0" (0.0cm) 6.0" (15.24cm) In addition to the above clearances there must also be at least 16 inches (40.64cm) of aisle space in front of the unit.
INSTALLATION SRTE: Electric Floor Model Rethermalizer 1.4. PLUMBING CONNECTIONS The plumbing installation should be done by a licensed plumber and must comply with local and national codes. 1.4.1. WATER INLET CONNECTIONS If a faucet or water fill option is equipped on your appliance connections to a potable water supply will be required. If a single water connection is required it is recommended that the appliance is connected to hot water supply.
INSTALLATION 1.5. ELECTRICAL CONNECTIONS It is advised that this power supply be plugged into a wall receptacle that is controlled by the ventilation control. This will prevent the appliance from being operated without the ventilator on. If your appliance requires an electrical connection, the power requirements are listed below.
INSTALLATION SRTE: Electric Floor Model Rethermalizer 1.6. VENTILATION AND FIRE SAFETY SYSTEMS Your new appliance must have proper ventilation to function safely and properly. It is very important to install a fire safety system. Your ventilation system should be designed to allow for easy cleaning. Frequent cleaning and proper maintenance of the ventilation system and the appliance will reduce the chances of fire. Ventilation and fire safety systems must comply to local and national codes.
OPERATION 2. OPERATION An operator’s manual for your appliance’s specific control type should be included with this manual. Refer to that manual prior to operating this appliance. 2.1. OPERATIONAL FEATURES The diagram below outlines some of the key operational components of your appliance. Refer to the following sections of this manual to learn more about these features. 6 L20-292, rev.
SRTE: Electric Floor Model Rethermalizer OPERATION 1. Cook Tank 2. Controller (Not on all Models) Controls the water temperature inside the cook tank. Optional timers are located on the controller (if equipped). If the controller has an ON/OFF button, it will be used to turn ON the controller as well as other features on the appliance. 3. Door (Shown Open) Provides access to the drain valve handle, high temperature reset button and gas valve, pilot, burners and shutoff valves. 4.
OPERATION 2.2. FILLING THE APPLIANCE 2.2.1. FILLING THE COOKER TANK It is recommended that the cooker tank is filled with hot water. This will greatly decrease the time it takes for the appliance to reach operating temperature. Refer to the following procedure to fill the cook tank prior to operation. CAUTION This appliance is not designed for cooking with oil. Fill with potable water only. DRAIN VALVE CLOSED 1. Ensure that the drain valve is closed. 2.
OPERATION SRTE: Electric Floor Model Rethermalizer 2.3. APPLIANCE START UP Refer to the following procedure to start the appliance prior to operation. 1. Ensure that the drain valve is closed. 2. Fill the cook tank with water. (See section 2.1 “Filling the Appliance”) 3. Turn the I/0 (ON/OFF) switch to the I (ON) position. WARNING NEVER operate the appliance with an empty cook tank. It may void the warranty.
OPERATION 2.4.3. TIMER OPERATION Not all control types include timers. Timers provide accurate cook times for multiple product quantities and types. Refer to the operator’s manual for your appliance’s specific control type to determine how to set the cook timers if equipped. To start a timer: Press the appropriate timer button. Typical Timer Buttons* *Timer buttons may appear slightly different then shown.
SRTE: Electric Floor Model Rethermalizer PREVENTATIVE MAINTENANCE 3. PREVENTATIVE MAINTENANCE 3.1. DAILY PREVENTATIVE MAINTENANCE Performing the preventative maintenance steps below on a daily basis will keep your equipment safe and at peak performance. During the cooking process, starch build up will form on the temperature probes, tank and heating element. It may be necessary to clean these components more then once a day.
PREVENTATIVE MAINTENANCE 3.2. MONTHLY PREVENTATIVE MAINTENANCE Water can leave mineral deposits inside the tank. Performing the monthly preventative maintenance steps below will keep your equipment safe and at peak performance. It may be necessary to clean these components more then once a month. 3.2.1. DELIMING 1. Read the “operation” section of this manual prior to filling or operating the appliance. 2. Following the manufacturer’s deliming instructions, remove deposits from the tank’s interior. 3.
SRTE: Electric Floor Model Rethermalizer PREVENTATIVE MAINTENANCE 3.3.5. TANK Verify that the tank is in good condition. Check for scale build up and inspect for signs of corrosion. Verify that tank is leak free. Check drain overflow (if equipped) for scale build up and debris blockage. 3.3.6. DRAIN SYSTEM Verify that drain valve is in good condition. Check for leaks in the seal area and fitting region. Verify that drain lines are leak free, kink free and in good condition.
TROUBLESHOOTING 4. TROUBLESHOOTING 4.1. POWER FAILURE If electric power is removed for any reason, the appliance will shut down. To restart the appliance, follow the appliance start up procedure in section 2.2. CAUTION DO NOT attempt to operate this appliance during a power outage. 4.2. HIGH TEMPERATURE LIMIT This appliance is equipped with a high temperature limit switch. The high temperature limit switch will stop the appliance from functioning if the internal cook tank reaches an unsafe temperature.
TROUBLESHOOTING SRTE: Electric Floor Model Rethermalizer 4.4. TROUBLESHOOTING CHART Problem Probable Causes No power to appliance. Circuit Breaker tripped. Corrective Actions Check main building power supply. Reset circuit breaker. Controller does not Flip I/0 switch to I position and turn on I/0 Switch in 0 position. activate. controller. Controller not turned on. Turn on controller. Power Cord loose or not connected. Connect power cord. Turn on water. Autofill does not add Water not turned on. water.
In the event of problems with or questions about your order, please contact the Pitco Frialator factory at: (603) 225-6684 World Wide Website Address: www.pitco.com In the event of problems with or questions about your equipment, please contact the Pitco Frialator Authorized Service and Parts representative (ASAP) covering your area, or contact Pitco at the numbers listed to the left. MAILING ADDRESS – P.O. BOX 501, CONCORD, NH 03302-0501 SHIPPING ADDRESS – 10 FERRY ST., CONCORD, NH 03301 L20-292, rev.