Gas connection instructions
• Check that installation or local distribution regulations (type of gas and gas pressure) match the setting value of this
device.
• The setting values of this device are indicated on the type plate.
• This device is not equipped with a combustion gas drain installation. Installation and connection must comply with the
regulations in force locally and nationwide. You must check the regulations in regards to ventilation requirements.
• The gas connection must comply with the general regulations. We recommend to connect the hob with a fixed gas pipeline
or to use an approved gas hose.
• Always use a full metal hose behind the oven.
• An approved gas hose should not be kinked and should not come into contact with moving parts of the kitchen furniture.
• The main gas supply must be in an easily accessible place.
• Before using the cooking unit check all the connections for leaks with soapy water.
2 Connection: gas and electrical
• The electrical installation must conform to the national and local regulations.
• Power socket and plug must always be reachable.
• Connect the unit with the supplied plug to an earthed socket.
• Damage to the connection cable may only be replaced by the manufacturer, or an approved Installer. This to prevent
dangerous situations.
Electrical connection instructions
110 V – 60 Hz – 0,6 VA