A. Make sure the opening is the correct
size. Use the table below to nd the
correct dimensions for a straight wall
with two jambs.
ProVantage
®
II
Wall Anchor Construction
Using 8" High Glass Block
Rough Opening Width (Inches)
4" Block
Width
Number
of Blocks
4-1/4
8-1/8
12
15-7/8
19-3/4
23-5/8
27-1/2
31-3/8
35-1/4
39-1/8
43
46-7/8
1
2
3
4
5
6
7
8
9
10
11
12
8-1/4
16-1/4
24-1/8
32
39-7/8
47-5/8
55-1/2
63-1/4
71-1/8
79
86-7/8
94-3/4
6-1/4
12-1/8
18
23-7/8
29-3/4
35-5/8
41-1/2
47-3/8
53-1/8
59
64-7/8
70-3/4
*
Note: 4" x 8", 6" x 8", and 8" x 8" blocks are all nominally 8" high.
Rough Opening
Height (Inches)
8" High Block*
8-1/2
16-1/8
23-7/8
31-7/8
39-3/4
47-1/2
55-1/2
63-1/4
71-1/8
79
86-7/8
94-7/8
8" Block
Width
6" Block
Width
B. If installing glass block with angled wall sections
follow these steps:
For walls with angles it is recommended that you
layout your wall before constructing a curb.
Make sure the angled sections of your opening
or curb are congured correctly.
The curb must be as wide as, or wider than, the
glass block thickness (4" or wider).
Apply nish material to the curb. The curb will be
visible through the glass blocks. If installing
the glass blocks in a wet environment, take steps
to ensure that the curb is waterproof.
Use a level to make sure the opening is level and
plumb.
If there are any problems with the opening or
curb, adjust it before proceeding.