6 Single contact blocks Selection diagram CONTACT BLOCKS CONNECTIONS 10G 01G 1NO slow action 1NC slow action silver contacts (standard) 10L 1NO leading slow action 01K 1NC lagging slow action G silver contacts gold plated FIXING V clamping screws P panel 41 S weld on printed circuit F base Control and signalling devices line
6 Contact block code structure article options E2 CP01G2V1-G Fixing P F Contacts type panel base silver contacts (standard) G Contact block 01G 1NC slow action 10G 1NO slow action 01K 1NC lagging slow action 10L 1NO leading slow action 1NC slow self-monitored action 01S (only clamping screw) Contact current handling 2 Ith 10A silver contacts gold plated Protection degree 0 1 2 IP00 solder connection IP20 screw connection IP20 screw connection with dust protection (only panel fixing) Type of conne
6 Single contact blocks Technical data General data Protection degree: Ambient temperature: Mechanical endurance: Max operating frequency: Utilization requirements: IP20 on the terminals according to IEC 60529 -40°C +80°C 20 million operations cycles 3600 operations cycles/hour see page 78 Contact block Contacts commutation force: 1,8 N (NO) / 1,4 N (NC) 1,7 N (NO leading) / 1,4 N (NC lagging) 3,5 N (NO) / 2,3 N (NC) 3,5 N (NO leading) / 1,9 N (NC lagging) 17 N min 1 mm/s max 0,5 m/s silver contacts (st
6 Data type approved by UL Utilization category: Data type approved by IMQ Rated insulation voltage (Ui): 500 V Thermal current in free air (Ith): 10 A Thermal current in housing (Ithe): 10 A Rated impulse withstand voltage (Uimp):8 kV Housing protection degree: IP20 Terminals: screw clamps Category of use: AC15 A600 pilot duty (720 VA, 120-600 Vac) Q300 pilot duty (69 VA, 125-250 Vdc) Note: - Use copper wire (Cu) 60 or 75 °C rigid or flexible with cross section12-20 AWG.
6 Single self-monitored contact blocks Technical data General data Protection degree: Ambient temperature: Mechanical endurance: Max operating frequency: Utilization requirements: Contact block Contacts commutation force: Actuating force at end travel: Positive opening force: Velocità di azionamento: Contacts material: IP20 on the terminals according to IEC 60529 -40°C +80°C 20 million operations cycles 3600 operations cycles/hour see page 78 2,9 N 5N 17 N min 1 mm/s max 0,5 m/s silver contacts (standard
Contact block selection table 5 pcs packs Panel fixing Screw connection Contact block E2 CP01S2V1 1NC slow selfmonitored action 2.3 0.8 0 1.1 Base fixing Screw connection Contact block 2.1 5 E2 CF01S2V1 1NC slow selfmonitored action 2.3 0.8 0 1.1 2.1 5 Complete units with contact block and fixing adapter Contacts pos 2 - pos 3 pos 1 - 1NC SELF-MONITORED Panel fixing Screw connection E2 AC-XXBC0139 E2 1BAC11 + E2 CP01S2V1 Dimensions Base fixing contact block E2 CF01S••• 25.