Datasheet

Safety switches with separate actuator
Please contact our technical service for the list of type approved products.
Please contact our technical service for the list of type approved products.
Data type approved by IMQ and EZU Data type approved by UL
Utilization categories Q300 (69 VA, 125-250 VDC)
A600 (720 VA, 120-600 VAC)
Data of the housing type 1, 4X (indoor use only), 12, 13
In conformity with standard: UL 508
For all contact blocks use 60 or 75 °C copper (Cu) conductor and wire size
No. 12-14 AWG. Terminal tightening torque of 7,1 Lb-In.
Rated insulation voltage (Ui): 500 VAC
400 VAC for contact blocks 20, 21, 22, 33, 34
Thermal current (Ith): 10 A
Protection against short circuits: fuse 10 A 500 V type aM
Protection degree: IP67
MV terminals (screw clamps)
Pollution degree 3
Utilization category: AC15
Operation voltage (Ue): 400 VAC (50 Hz)
Operation current (Ie): 3 A
Forms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+X
Positive opening of contacts on contact block 5, 6, 7, 9, 20, 21, 22, 33, 34
In conformity with standards: EN60947-1, EN 60947-5-1 and subsequent
modications and completions, fundamental requirements of the Low Voltage
Directive 73/23 EEC and subsequent modications and completions.
These safety switches are ideal to control gates, sliding doors and other guards protecting dangerous parts of machine. The stainless
steel actuator is fastened to the moving part of the guard, so it is removed from the switch on every opening of the guard. The switch
mechanism guarantees that removing the actuator forces the positive opening of the electrical contacts. Easy to install, these switches
can be applied to any kind of protection (with hinge, sliding and removable ones). Besides, the possibility to actuate the switch only with
its actuator guarantees that the machine can be restarted only when the guard has been closed. All products (except FW series) are
equipped with a particular mechanical hooking that does not allow the separation of the head from the body during its positioning.
Description
Rotating heads
Removing the two
fastening screws, in all
switches, the head can be
rotated in 90° steps.
Actuator regulation zone
This switch has a wide
backlash of the actuator into
the head (4,5 mm) for an
easier installation.
With closed door, check that
the actuator doesn’t knock
straight against the head of
the switch; it must be in the
adjustment zone (0,5…5 mm)
Versions with 30 N actuator extraction force
Versions with 30 N actuator
holding force instead of
the standard 10 N are
available.
Not detachable head
The action head type 93is completely
interchangeable and compatible with
previous head type 92, but it has the
advantage to be not detachable from the
switch body even if it is always adjustable
in 9 steps (Pizzato Elettrica patent).
The new head is safer because it cannot
be ruined during installation. The head
xing screws have been reduced to only
two (instead of the previous four) and so
the rotation operation will be quicker and
cheaper.
Do not use where dust and dirt may penetrate in any way into
the head and deposit there, in particular where metal dust,
concrete or chemicals are spread.
Do not use where explosive or inammable gas is present.
Limits of utilizationInstallation examples
Technical data
© 2005 Copyright Pizzato Elettrica
General Catalog 18
page 4/11
4
General Catalog 18
page 4/12
© 2005 Copyright Pizzato Elettrica
4